129
F3SG-SR/PG
User’s Manual
Chapter
2
O
pera
ting Rang
e Sel
ect
ion
System Operation and Functions
E
2-20-2. Factory Default Setting
The Operating Range Selection is configured as Long Mode. The operating range for the long mode
setting is from 0.3 to 20 m for F3SG-SR 25-mm/45-mm/85-mm detection capability model, from 0.3 m
to 10 m for F3SG-SR 14-mm detection capability model, and from 20 to 70 m for F3SG-PGA-L.
2-20-3. Setting with Intelligent Tap
The user can select the mode of Operating Range Selection by the DIP Switch.
• Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
• Under the optical synchronization setting, the operating range is determined by the wiring of the operating range
selection input line, regardless of the setting of the Intelligent Tap.
Refer to
Chapter 3 Setting with Intelligent Tap
for more information on setting this function by the Intelligent Tap.
2-20-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
• It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
• Under the optical synchronization setting, the operating range is determined by the wiring of the operating range
selection input line, regardless of the setting of the SD Manager 3.
Refer to
4-3-5-3. Operating Range Selection
for more information on changing functions by SD Manager 3.
Function name
Description
Initial value
Configurable value or numerical range
Operating Range Selection
Select the operating range.
Long mode
Short mode/Long mode
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...