G-50
Safety Sensors / Components
Decentralized Muting connection Box
Furthermore, using a F39-TGR-SB-CMB1, it’s possible to reduce the wiring time and wiring material for the mut-
ing Sensors and Muting Lamp etc.
In the conventional solution all wires from the light curtain, mute sensors, lamp,
reset are wired back to the mute controller in the control cabinet (See Ex. 1)
As you can see this solution need JUST ONE WIRE to the cabinet (See Ex. 2)
Multiple mute connections are possible
1. PARALLEL MUTING and TWO WAY direction
2. PARALLEL MUTING and ONE WAY direcion
3. CROSS MUTING and TWO WAY direction
4. CROSS MUTING and ONE WAY direction
Muting Sensors Recommendation
It is recommended to use the E3Z or E3G as muting sensor. Please refer to the E3Z datasheet
Cat.No. E701-E2-Cat04-01
and
the E3G datasheet
Cat.No. E278-E2-Cat04-03
.
SOLUTION 1: Object Gaps
In many palletiser applications
there is a gap between objects
on the pallet. The Muting function
may not work correctly because
of this gap. To avoid the mutual
interruption, we recommend to
Use E3G
@@@@
T as muting sen-
sor. E3G-
@@@@
T has ON delay
timer internally (0 to 5 seconds)
SOLUTION 2: Misalignment of pallets
When using a
CROSS MUTING
system, It may
cause that unex-
pected behavior
when the pallets get
out of alignment
then E3G
@@@@
T
also solves the
problem by OFF delay timer (0 to 5 seconds).
To Barrier
To Cabinet
Ex. 1
Ex. 2
Pallet
A2 B2
B1 A1
Danger Zone
Danger Zone
Pallet
A2 B2
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
Danger Zone
Pallet
B2
A2
Danger Zone
Pallet
B2
A2
Please add MTL*. Ex. F3S-TGR-SB4-K1CMTL
Reference
Muting Lamp
Override and Test Switch
F3S-TGR-SB
@
-K
@
C
Muting sensor
F3S-TGR-SB-CMB
@
Mechanical Guard
*MTL
has a special software inside of F3S-TGR-SB
@
C which works to finalize a Muting function.
Object
Gaps
F502-EN2-04.book Seite 50 Dienstag, 26. Juli 2005 5:48 17