background image

1

Pressure Sensor

E8F

Pressure Sensor with an Easy-to-see
Digital Display

Two output modes ensure easy pressure control.

Compact model incorporates a self-diagnostic
function.

Washable (IP66).

SI-compatible models are available.

Ordering Information

Pressure range

ON/OFF output

Linear output

Model

Positive pressure

0 to 98 kPa

NPN open collector

1 to 5 V

E8F-A01C

os

e

essu e

0 to 980 kPa

o e co ec o

o 5

E8F-B10C

Negative pressure

0 to –101 kPa

E8F-AN0C

Positive pressure

0 to 1 kgf/cm

2

E8F-01C

os

e

essu e

0 to 10 kgf/cm

2

E8F-10C

Negative pressure

0 to –76 cmHg

E8F-CN0C

Application Examples

Checking the wafer pick-up

Air leakage test on container pin holes
or cracks

E8F

E8F

Checking the chip pick-up

E8F

Checking the air press machine
pressure

E8F

Checking the PCB and wafer pick-up

E8F

Output

Control of air chuck clamp pressure

E8F

Содержание E8F

Страница 1: ...98 kPa NPN open collector 1 to 5 V E8F A01C os e essu e 0 to 980 kPa o e co ec o o 5 E8F B10C Negative pressure 0 to 101 kPa E8F AN0C Positive pressure 0 to 1 kgf cm2 E8F 01C os e essu e 0 to 10 kgf c...

Страница 2: ...tput 6 ms max Linear output 1 to 5 V with output impedance of 1 k and permissible resistive load of 500 k min ON OFF output NPN open collector NO NC Load current 100 mA max Output applied voltage 30 V...

Страница 3: ...display in which the third digit displays only 0 or 1 0 or 1 0 to 9 0 to 9 Third digit Second digit First digit Characteristics Voltage influence 1 5 FS max Temperature influence 3 FS max Degree of p...

Страница 4: ...al E8F 01C Linearity Typical E8F 01C Linear output voltage V Pressure kgf cm2 Linearity deviation FS Pressure kgf cm2 Nomenclature LCD display 21 2 digit display DOWN Key UP Key Green indicator Normal...

Страница 5: ...sure ON point OFF point OFF point Output see note ON OFF OUT indicator red RUN indicator green ON OFF ON OFF Normally Closed Output in Hysteresis Mode OFF point 3 digits ON point 3 digits OFF point 3...

Страница 6: ...re stored in the EEPROM and not lost when the E8F is turned OFF If the Up Key is pressed in mea surement mode the set ON point will be displayed for two seconds If the Down Key is pressed instead the...

Страница 7: ...F 2 If there is an error other than a load short circuit or excessive current error i e E2 to E6 the green indicator will be turned OFF and the error output transistor will be turned ON Therefore null...

Страница 8: ...ted E8F Wiring cord Atmosphere inlet M5 screw depth 6 R PT 1 8 zinc die cast 1 dia hole Two M2 5 x P0 45 Wiring cord 3 dia Mounting Bracket Mounting Dimensions Material SPCC uni chrome plating t 1 2 M...

Страница 9: ...tting at room temperature If a highly precise pressure setting is required use a manometer Nullify the ON OFF output at the time of error detection If the use of the E8F requires the IP66 enclosure ra...

Страница 10: ...E8F E8F 10...

Страница 11: ...E8F E8F 11...

Страница 12: ...ku Osaka 540 6028 Japan Phone 81 6 949 6012 Fax 81 6 949 6021 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0...

Отзывы: