The following displays are use to represent the characters for parameter names on the Temperature Controller.

Seven-segment Digital DIsplay

Eleven-segment Digital Display

Parameter Displays

A B C D E F G H

I

J

K

L M N O P Q R S T U V W X Y Z

A B C D E F G H

I

J

K

L M N O P Q R S T U V W X Y Z

a b c d e f g h i j k l m n o p q r s t u v w x y z

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

http://www.ia.omron.com/

C-3

(c)Copyright OMRON Corporation 2007   All Rights Reserved. 

Содержание E5ZN-DRT

Страница 1: ...ons from Temperature Controller to PLC The E5ZN Modular Temperature Controller is connected to the DeviceNet network The I O link function allows setting and monitoring e g of present values for the E5ZN Modular Temperature Controller to be performed without communications programming Up to 16 E5ZN Modular Temperature Controllers can be con nected to one Unit All the parameters for the E5ZN can be...

Страница 2: ... Example D f Use the DeviceNet Configurator for E5ZN initial settings and temperature control wiring to enable immediate execution DeviceNet Master POWER BPS UNIT ERROR SD RD OUT1 OUT2 SUB1 SUB2 E5ZN POWER BPS UNIT ERROR SD RD OUT1 OUT2 SUB1 SUB2 E5ZN POWER BPS UNIT ERROR SD RD OUT1 OUT2 SUB1 SUB2 E5ZN POWER BPS UNIT ERROR SD RD OUT1 OUT2 SUB1 SUB2 E5ZN E5ZN Measure the heater control time RUN tim...

Страница 3: ... DeviceNet Communications Unit 24 VDC E5ZN E5ZN DRT Terminal Unit E5ZN SCT24S Power supply voltage DeviceNet 24 VDC for internal circuits External input power supply 24 VDC for RS 485 communications circuits and Temperature Controllers Allowable voltage range DeviceNet 11 to 25 VDC External input power supply 20 4 to 26 4 VDC Power consumption See note 2 DeviceNet Approx 1 1 W for a current of 45 ...

Страница 4: ...onducted Disturbances EN61006 2 EN61000 4 6 10 V EMI Radiated Emissions electric field EN50081 2 Class A Transmission line connection method RS 485 multipoint Communications method RS 485 2 wire half duplex Synchronization method Start stop synchronization Baud rate 38 400 bps Transmission code ASCII Data bit length 7 bits Stop bit length 2 bits Error detection Vertical parity even BCC block check...

Страница 5: ...e connection configuration and I O allocation is set using simple I O allocation or Configurator I O allocation Used to copy backup parameters between the Temperature Controllers and DeviceNet UP DN Pin 2 Sets the copy operationmode i e upload or download COPY Pin 1 Starts the copying Indicators E5ZN DRT 30 72 8 27 35 46 89 6 107 5 4 7 130 Dimensions when Mounted to the E5ZN SCT24S Terminal Unit N...

Страница 6: ...sing a noise filter with the power supply be sure to confirm the voltage and the current and then mount the power supply as near as possible to the Temperature Con troller Set up the Temperature Controller along with its power sup ply as far away as possible from devices that generate strong high frequency waves such as high frequency weld ers and high frequency machines and from devices that gen ...

Страница 7: ... not to cool down the terminal sections alone to avoid measurement errors Measurement Accuracy 1 When extending the lead wires for thermocouples use a com pensating conductor appropriate for the type of thermocouple use 2 When extending the lead wires for platinum resistance ther mometers use lead wires with low resistance and make the resistance in the 3 lead wires equal 3 The type of Temperature...

Страница 8: ...U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 http www ia omron com C 3 c Copyright OMRON Corpo...

Страница 9: ... may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems...