E3X-NV/NVG

E3X-NV/NVG

Precautions

WARNING

AVOID EXPLOSION OR FIRE

The voltage supplied to the E3X-NV/NVG must be within

 the rated voltage range. If a voltage exceeding the rated
 upper limit is imposed on the E3X-NV/NVG.

Connect each power line of the E3X-NV/NVG correctly.

Do not short-circuit the load connected to the E3X-NV/NVG.

TURNING POWER ON

After the E3X-NV

 is turned on, it will be ready to operate in 100 ms

maximum. If power is supplied to the E3X-NV

 and the load is con-

nected to the E3X-NV

 independently, be sure to turn on the power

supply connected to the E3X-NV

 first.

When the E3X-NV

 is turned on or off, no control output will be ON,

even though the operation indicator of the E3X-NV

 will be lit for an

instant.

MUTUAL INTERFERENCE PROTECTION
FUNCTION

When closely connecting two to three Fiber Units to more than one
E3X-NV

, perform with/without-object teaching on a single E3X-

NV

 at a time. Turn on only the E3X-NV

 on which teaching is per-

formed. If all the E3X-NV

 are turned on, interrupt the emitters of

the Fiber Units on which teaching is not performed.

Power interruptions or noise caused by static electricity, etc., can re-
sult in write errors during any part of the teaching process. These
errors include buzzers, lighting of teaching indicators, simultaneous
flashing of red/green indicators, lighting of operation indicators, and
lighting or flashing of stability indicators. If any of these occur, re-in-
put teaching using the teaching button on the Amplifier.

Unlike experiencing teaching errors, if any memory error occurs,
red/green teaching indicators will flash simultaneously, and opera-
tion indicators and stability indicators will also flash.

WHEN POWER IS OFF

The instant power is turned off, the E3X-NV

 could output a pulse

signal which could affect the operation of the devices connected to
it. This will happen more often if power is supplied to the E3X-NV

from an external power supply, thus affecting the connected timer
and counter. Use a built-in power supply to avoid this.

CABLE

To extend the cable, use a wire with 0.3 mm

2

 min. The total length of

the cable should be 100 m max.

POWER SUPPLY

If a standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, or the E3X-NV

 can malfunction, influenced by the

switching noise of the power supply.

The supplied voltage must be within the rated voltage range. Unreg-
ulated full- or half-wave rectifiers must not be used as power sup-
plies.

INSTALLING/WIRING

Do not wire the amplifier in the same conduit with power lines. Doing
so would cause induction between the lines, possibly resulting in
faulty operation or destruction. Always provide separate conduit for
the wiring to the amplifier.

Power line

Cat. No. CEDSAX3

 10/99

Specifications subject to change without notice.

Printed in U.S.A.

OMRON ELECTRONICS, INC.

One East Commerce Drive
Schaumburg, IL 60173

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.

1-800-55-OMRON

OMRON CANADA, INC.

885 Milner Avenue
Scarborough, Ontario M1B 5V8

416-286-6465

Содержание E3X-NV

Страница 1: ...Object Teaching capability speeds setup Rated IP66 can withstand light washdown Remote teach function allows easy remote teaching from the controller Mounts on DIN rail track Uses E32 series fiber opt...

Страница 2: ...or no light Teaching function Remote input Remote input is ON when pink and blue wires short circuited Remote input is OFF when pink and blue wires are not shorted Confirmation Red green LED indicator...

Страница 3: ...black terminals Between brown and black terminals Operation indicator orange Output transistor Load relay E3X NV21 NVG21 Incident Interrupted ON OFF ON OFF Operates Releases WITH WITHOUT OBJECT TEACHI...

Страница 4: ...ng level to 10 of the light level The light value decreases and the photoelectric sensor works in through beam operation Operating level 10 10 Light Light Change to RUN mode 3 Detectable objects conti...

Страница 5: ...N OFF Remote teach input With Without object teaching H L T1 T2 T1 T1 0 5 to 2 s T2 3 s min Maximum sensitivity setting H L T3 T3 5 s min No object teaching H L T4 T5 T4 T4 0 5 to 2 s T5 1 5 to 2 s OP...

Страница 6: ...98 59 2 32 9 0 35 11 0 43 0 16 22 5 0 89 13 0 51 16 0 63 37 1 46 22 5 0 89 3 4 2 0 08 16 0 63 6 0 24 3 9 0 15 0 4 12 5 0 49 8 4 0 33 8 0 31 4 59 12 33 2 Installation CONNECTION Connection with S3D2 Se...

Страница 7: ...sconnection Push up the lock lever so that the fiber optic cable can be removed To avoid damage make sure that the fiber is unlocked before re moving AMPLIFIER Mounting 1 Mount the front part on the m...

Страница 8: ...sing the teaching button on the Amplifier Unlike experiencing teaching errors if any memory error occurs red green teaching indicators will flash simultaneously and opera tion indicators and stability...