manualshive.com logo in svg
background image

E3X-SD/-NA

7

Ratings and Specifications

Amplifier Units

*1. For the E3X-NA, residual voltage is 1 V max.
*2. When there are 8 or more E3X-NA Amplifiers mounted side-by-side, the response time will be 350 

µ

s max.

*3. The E3X-NA does not have output reverse polarity prevention.
*4. Water-resistant models and models with connectors have a dielectric strength of 500 VAC. 
*5. Add 10 g for water-resistant models.

Amplifier Unit Connectors

Type

Digital display and direct key setting

Bar display and adjuster setting

Standard models

Standard models

High-speed detection 

models

Water-resistant models

Model

E3X-SD

@

E3X-NA

@

E3X-NA

@

F

E3X-NA

@

V

Item

Light source (wavelength)

Red LED (620 nm)

Red LED (680 nm)

Power supply voltage

12 to 24 VDC 

±

10%, ripple (p-p): 10% max.

Current consumption

960 mW max. (Power supply: 24 V, 
Current consumption: 40 mA max.)

35 mA max.

Control output

Open-collector output (NPN or PNP) 
Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) (*1)
Light-ON/Dark-ON mode selector

Response time

Operate or reset: 200 

µ

s max. (*2)

Operate: 20 

µ

s max.

Reset: 30 

µ

s max.

Operate or reset: 200 

µ

max. (*2)

Sensitivity adjustment

UP/DOWN direct key setting, teaching

8-turn sensitivity adjuster (with indicator)

Protection circuits

Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection (*3)

Timer function

ON/OFF-delay timer: 10 ms (each fixed)

OFF-delay timer: 40 ms (fixed)

Mutual interference 
prevention

Up to 5 Amplifiers (optically synchronized)

None

Up to 5 Amplifiers (optical-
ly synchronized)

Ambient illumination

Receiver side
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.

Ambient temperature 
range

Operating: Groups of 1 to 3 Amplifiers: 

25

°

C to 55

°

C

Groups of 4 to 11 Amplifiers: 

25

°

C to 50

°

C

Groups of 12 to 16 Amplifiers:

25

°

C to 45

°

C

Storage: 

30

°

C to 70

°

C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 M

. min. (at 500 VDC)

Dielectric strength

1,000 VAC at 50/60 Hz for 1 minute (*4)

Vibration resistance

Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions

Shock resistance

Destruction: 500 m/s

2

, for 3 times each in X, Y and Z directions

Degree of protection

IEC 60529 IP50 (with Protective Cover attached)

IEC 60529 IP66
(with Protective Cover at-
tached)

Connection method

Pre-wired (standard cable length: 2 m), or connector

Weight (packed state)

Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g (*5)

Material

Case

Polybutylene terephthalate (PBT)

Cover

Polycarbonate

Polyethersulfone (PES)

Accessories

Instruction manual

Item

Model

E3X-CN11

E3X-CN12

Rated current

2.5 A

Rated voltage

50 V

Contact resistance

20 m

 max. (20 mVDC max., 100 mA max.)

(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the 
cable.)

Number of insertions

Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)

Material

Housing

Polybutylene terephthalate (PBT)

Contact

Phosphor bronze/gold-plated nickel

Weight (packed state)

Approx. 55 g

Approx. 25 g

Содержание E3X-NA Series

Страница 1: ...E3X SD NA Series NEW Digital Display Direct Key Setting Simple Fiber Amplifiers Bar Display Manual Setting The Series now includes models with digital displays and direct key setting Simplicity and H...

Страница 2: ...supply pin Master Connector Slave Connector 1 E3X NA E3X SD A timer function is provided as a standard feature The switch is for the timer only so no complicated operation is required Compact No mode...

Страница 3: ...Prevent Mutual Interference for Up to Five Amplifiers 400 mm Standard Fiber Unit E32 TC200 Sufficient distance performance A maximum distance of 14 m can be achieved by using a Long distance Fiber Un...

Страница 4: ...A S Standard models E3X DA AN S Easy measurement control using analog output E3X DAC S Color sensing models with white LEDs Stable detection with resistance against workpiece movement NEW NEW Digital...

Страница 5: ...splay and Direct Key Setting Bar Display and Adjuster Setting Item Appearance Connection method Ratings and Specifications Model NPN output PNP output Standard models Pre wired E3X SD11 E3X SD41 Wire...

Страница 6: ...2 A 5 m XS3F M422 405 A Combining Amplifier Units and Connectors Amplifier Units Applicable Connectors Order Separately Type NPN PNP Master Connector Slave Connector Basically Amplifier Units and Conn...

Страница 7: ...lifiers optically synchronized None Up to 5 Amplifiers optical ly synchronized Ambient illumination Receiver side Incandescent lamp 10 000 lux max Sunlight 20 000 lux max Ambient temperature range Ope...

Страница 8: ...odels Reflective Fiber Units Size 15 10 3 mm Flat and flexible fiber models are easy to mount and will not break 20 mm Flat View E32 D15ZR Flexible fiber Conventional fiber Cladding Cores No Breaking...

Страница 9: ...E32 T11R E39 F1 2100 630 E32 T11 E39 F1 2000 600 E32 T14 1800 540 E32 T11L E32 T12L 700 210 E32 T11L E39 F2 500 150 E32 T11R E39 F2 220 65 E32 T11 E39 F2 360 100 E32 T21L E32 T22L 200 60 Ultracompact...

Страница 10: ...E32 D33 10 3 3 E32 D331 1 5 0 5 Coaxial small spot E32 CC200R 75 25 E32 CC200 150 50 E32 D32L 80 25 E32 C31 E32 D32 40 13 E32 C42 E39 F3A Spot diameter of 0 1 to 0 6 mm at 6 to 15 mm E32 D32 E39 F3A S...

Страница 11: ...No incident light ON OFF ON OFF Operate Reset Operation indicator orange Between brown and black leads Output transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Reset Oper...

Страница 12: ...power supply polarity 7 Connect the load properly 8 Do not short circuit both ends of the load 9 Do not use the product if the case is damaged 10 When disposing of the product dispose of it as indust...

Страница 13: ...nnection and Disconnection The E3X Amplifier Unit has a lock lever Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures 1 Connection Open the Protective Co...

Страница 14: ...separated press down on the lever on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Mounting End Plate PFP M Depending on how...

Страница 15: ...ator diameter 1 1 mm Standard length 2 m Hole for optical communications 2 Amplifier Units with Cables E3X SD11 E3X SD41 E3X NA11 E3X NA11F E3X NA41 E3X NA41F With Mounting Bracket Attached Amplifier...

Страница 16: ...cross section 0 45 mm2 Insulator diameter 1 1 mm Standard length 2 m Amplifier Units with Cables Water resistant Models E3X NA11V E3X NA41V With Mounting Bracket Attached 12 8 10 7 4 3 9 9 3 4 3 9 33...

Страница 17: ...m2 Insulator diameter 1 1 mm Slave Connector E3X CN12 14 4 2 6 3 6 2 9 10 0 8 8 4 6 8 10 7 2 000 50 0 50 5 0 30 2 E3X CN12 2 6 dia E3X CN22 4 dia 10 2 4 15 1 6 E3X CN12 2 6 dia vinyl insulated round c...

Страница 18: ...0 Unstable incident light or Unstable interrupted light 0 90 max Stable interrupted light Operation description Switch Key Display Set the TEACH RUN selector switch to TEACH Press the UP Key for 3 s m...

Страница 19: ...ed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control s...

Страница 20: ...ommerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835...

Отзывы: