E3X-MDA
E3X-MDA
5. Setting Functions in SET Mode
* The default settings are shown in the transition boxes between functions.
UP
DOWN
MODE
UP
MODE
UP
DOWN
MODE
MODE
UP
DOWN
MODE
*1
MODE Key
y
UP
DOWN
UP
DOWN
MODE
L-PE
D-BT
L-BT
D-PE
PEAK
UP
DOWN
MODE
MODE
UP
DOWN
MODE
SET
Dark ON
Light ON
Set the Mode Selector
to SET.
Light Level and Threshold Display
Switch to desired
function.
Detection
Changes the setting.
Operation
mode
m
Standard mode
Super-high-speed mode
High-resolution mode
Timer
OFF-delay timer
Timer disabled
ON-delay timer
One-shot timer
Time
Enables the tim
20 to 200 ms
200 ms to 1 s
5-ms increments
1 to 20 ms 1-ms increments
100-ms increments
1 to 5 s
1-s increments
Setting range: 1 to 5,000 ms
Display
switch
(To change the display method)
Executes a zero reset.
Executes power tuning.
Power tuning
Setting range: 100 to 3,900 (increments of 100)
Maximum power
M
Display
orientation
orientation
(To reverse the orientation of the display.)
Up/down reversed display
Normal display
*1
Light levels for channels 1 and 2
The incident light level and the threshold value.
The incident light level as a percentage of the
threshold value and the threshold value.
The incident light peak level and no incident light
bottom level.
(Refreshed when output turns ON or OFF.)
(
)
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red; OFF: Green)
The current incident light level and the peak
incident light level.
Light level
The incident light level and the channel.
Channel
The min. incident light peak level and max. incident
light bottom level, showing min. width of light level
change. (Refreshed when output turns ON/OFF
ten times.)
interval
Teaching: Refer to page A-371 4. Teaching the Threshold Value (SET Mode).
Refer to page A-371 1. Setting the Operation Mode.