E3X-DA-N

A-419

E3X-DA-N

Digital Fiber Amplifier

E3X-DA-N

Truly ultimate fiber amplifier 
in pursuit of "user friendliness" 
and "high performance"

UL991*

Features

Reducing power line wiring meaning 
space is saved. New design for easier 
maintenance.

The connector type that uses the wire-saving connector sup-

plies power to the single-conductor slave connectors via the

three-conductor master connector. Hence, the following three

has been made possible.

1. Wiring is much simpler.
2. Relay connectors are not required meaning that space is used

more efficiently and costs are reduced.

3.  Simple inventory control because of no differentiation between

master and slave in the amplifier section.

Super digital display by use of the Auto 
Power Control (APC) circuit

The incident level of LEDs used in sensors is prone to deteriorate
with time and as a result, detection becomes unstable.

Using the APC (auto power control) circuit for the first time as the
fiber sensor, the E3X-DA-N series has no digital value variations,
realizing severe detection.

This makes the E3X-DA-N ideal for applications where a high de-
gree of sensitivity is required, such as detecting crystal glass.

Industry First

Patent pending

Master Connector

New Connector Design

Power supply pin

Slave Connector

Up to 16 Amplifiers 
can be connected together.

Optical 
commu-
nications

Industry First

Incident level

Time

Threshold

3000

Detection becomes unstable

Incident level

Time

Threshold

3000

Stable detection

Conventional 
Digital Fiber 
Amplifiers

E3X-DA-N Series

* UL-listed including UL991 tests/evaluations   Applicable standard: UL3121-1   Standards for additional tests/evaluations 

for applications: UL991, SEMI S2-0200

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание E3X-DA-N series

Страница 1: ...vel of LEDs used in sensors is prone to deteriorate with time and as a result detection becomes unstable Using the APC auto power control circuit for the first time as the fiber sensor the E3X DA N se...

Страница 2: ...W 1800mW This ECO label is indicated on products that meet the environmental standards established by OMRON Eco mode Setting teaching fine adjustment can be made at the fiber front end The Mobile Cons...

Страница 3: ...Connector order separately Control output Model NPN output PNP output Standard models Master E3X CN11 ON OFF output E3X DA6 E3X DA8 Slave E3X CN12 Monitor output models Master E3X CN21 ON OFF output...

Страница 4: ...s ac cessories Power supply provid ed by chargeable battery E3X MC11 C1 Mobile Console E3X MC11 H1 Head E39 Z12 1 Cable 1 5 m Straight connector L shaped connector In general amplifier units and conne...

Страница 5: ...ively Standard mode Operation reset 1 ms each 2 ms for operation and reset respectively Super long dis tance mode 4 ms for operation and reset respectively 7 ms for operation and reset respectively Se...

Страница 6: ...A9 E3X DAB8 E3X DAG8 E3X DAH8 E3X DA44V E3X DA8TW Connection method Connector type M8 connector Connector Weight Packed state Approx 55 g 65 g Approx 55 g Type Standard models Monitor out put models M...

Страница 7: ...0 1260 240 1680 1 mm dia 0 01 mm dia E32 ET21R 50 60 80 30 40 50 E32 T16WR 580 690 910 350 450 580 0 3 mm dia 3 3 The digital value is 1000 and the value can be detected in each detection area Refer t...

Страница 8: ...mode 270 500 s 1 2 4 10 20 30 50 100 200 ms selectable Both side edge detection mode 570 s 1 2 4 10 20 30 50 100 200 400 ms selectable Func tions Timer function OFF delay timer for L ON ON delay time...

Страница 9: ...2 4 3 T Incident light No incident light ON OFF ON OFF Operate Release Operation Indicator orange Between brown and black Output transistor Load relay Incident light No incident light ON OFF ON OFF Op...

Страница 10: ...transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Release Operation Indicator orange Between blue and black Output transistor Load relay Main circuit Load Load Monitor out...

Страница 11: ...Monitor output Orange E3X DA N 12 to 24 VDC 12 VDC 80 mA K3NX VD2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Use this service power supply for the Sensor with reference to the power consumption of eac...

Страница 12: ...ging the Display RUN Mode Manual Tuning Fine Sensitivity Adjustment in ADJ Mode Perform fine sensitivity adjustment after teaching and manual tuning without using the teaching function in the way show...

Страница 13: ...pper limit that is lower than the lower limit Setting lower limit for monitoring Alternates between A LO and setting value Factory setting Note It is not possible to set an lower limit that is lower t...

Страница 14: ...rating mode for the channel set with the channel selection switch can be changed SET CH1 CH2 Changed using the channel selection switch Channel 1 Channel 2 2s MODE TEACH TEACH TEACH TEACH TEACH TEACH...

Страница 15: ...to SET 2 Press the SET button once about 1 s 3 Setting is completed when the red level indicators are turned ON They then return to the digi tal incident level display 4 Set to RUN mode 5 The thresho...

Страница 16: ...ration mode and area de tection cannot be set Adjustment Mutual interference prevention function The digital display value may vary due to the light from the other sensor In that case low the sensitiv...

Страница 17: ...onnectors without separating them from other amplifier units first Mounting End Plate PFP M Depending on the installation an amplifier unit may move dur ing operation In this case use an end plate Bef...

Страница 18: ...t level display Threshold level display With Mounting Blanket Attached Mounting Holes prewired E3X DA11 N E3X DAG11 N E3X DA21 N E3X DAH11 N E3X DAB11 N E3X DAB41 N E3X DA41 N E3X DAG41 N E3X DA51 N E...

Страница 19: ...tached Mounting Holes Amplifier units with Cables Twin output Models E3X DA11TW E3X DA41TW 10 64 3 3 8 Two 2 4 dia 10 7 9 9 3 4 38 6 13 3 9 5 1 1 7 4 2 6 2 1 7 36 7 14 31 5 5 5 Hole for optical commun...

Страница 20: ...ts M8 Connectors Water resistant Models E3X DA14V E3X DA44V 10 64 3 3 8 Two 2 4 dia 10 7 9 9 3 4 38 6 13 3 9 5 1 1 7 4 2 6 2 1 7 36 7 14 31 5 5 5 Hole for optical communications 1 8 13 05 Incident lev...

Страница 21: ...insulated round cable conductor cross sectional area 0 2 mm insulation diameter 1 1 mm is used E3X CN22 A 4 dia 2 conductor vinyl insulated round cable conductor cross sectional area 0 2 mm insulatio...

Страница 22: ...use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems a...

Отзывы: