Do not use the product in atmospheres or environments that 
exceed product ratings.

Amplifier Units

Designing

Communications Hole

The hole on the side of the Amplifier Unit is a communications 
hole for preventing mutual interference when Amplifier Units 
are mounted side-by-side. The E3X-MC11 Mobile Console 
(order separately) cannot be used.
If an excessive amount of light is received via the Sensor, the 
mutual interference prevention function may not work. In this 
case, make the appropriate adjustments using the sensitivity 
adjuster.
The mutual interference prevention function will not operate 
when the E3X-SD/NA is used side-by-side with E3X-DA-N 
models.

Mounting

DIN Track Mounting/Removal

Mounting Amplifier Units

1. Mount the Amplifier Units one at a time onto the DIN track.

2. Slide the Amplifier Units together, line up the clips, and 

press the Amplifier Units together until they click into place.

Removing Amplifier Units

Slide Amplifier Units away from each other, and remove from 
the DIN track one at a time. (Do not attempt to remove 
Amplifier Units from the DIN track without separating them 
first.)

Fiber Connection and Disconnection

The E3X Amplifier Unit has a lock lever. Connect or 
disconnect the fibers to or from the E3X Amplifier Unit using 
the following procedures:

1. Connection

Open the Protective Cover, insert the fibers according to the 
fiber insertion marks on the side of the Amplifier Unit, and 
lower the lock lever.

2. Disconnection

Remove the Protective Cover and raise the lock lever to pull 
out the fiber.

Note:

To maintain the fiber properties, confirm that the lock is 

released before removing the fiber.

3. Precautions for Fiber Connection/Disconnection

Be sure to lock or unlock the lock lever within an ambient 
temperature range between 

10

°

C and 40

°

C.

Operating Environment

Ambient Conditions

If dust or dirt adhere to the hole for optical communications, it 
may prevent normal communications. Be sure to remove any 
dust or dirt before using the Units.

Other

Protective Cover

Be sure to mount the Protective Cover before use.

Precautions for Correct Use

Note 1.

The specifications for ambient temperature will vary according to the 
number of Amplifier Units used together. For details, refer to 

Ratings 

and Specifications

.

2.

Always turn OFF the power supply before mounting or removing 
Amplifier Units.

Click into
place

Clip

Lock le

v

er

Fi

b

er

Fi

b

er insertion mark

10.7 mm

Insertion position

Locked

Unlocked

Protecti

v

e Co

v

er

Содержание E3X-CN11

Страница 1: ...Stickers for Connectors are included as accessories Item Appear ance Cable length No of conductors Model Master Connector 2 m 3 E3X CN11 Slave Connector 1 E3X CN12 Combining Amplifier Units and Conne...

Страница 2: ...o 11 Amplifiers 25 C to 50 C Groups of 12 to 16 Amplifiers 25 C to 45 C Storage 30 C to 70 C with no icing or condensation Ambient humidity range Operating and storage 35 to 85 with no condensation In...

Страница 3: ...dels Reflective Fiber Units Size 15 10 3 mm Flat and flexible fiber models are easy to mount and will not break 20 mm Flat View E32 D15ZR Flexible fiber Conventional fiber Cladding Cores No Breaking F...

Страница 4: ...0 E39 F1 3000 E32 T11R E39 F1 2100 E32 T11 E39 F1 2000 E32 T14 1800 E32 T11L E32 T12L 700 E32 T11L E39 F2 500 E32 T11R E39 F2 220 E32 T11 E39 F2 360 E32 T21L E32 T22L 200 Ultracompact ultrafine sleeve...

Страница 5: ...xial small spot E32 CC200R 75 E32 CC200 150 E32 D32L 80 E32 C31 E32 D32 40 E32 C42 E39 F3A Spot diameter of 0 1 to 0 6 mm at 6 to 15 mm E32 D32 E39 F3A Spot diameter of 0 5 to 1 mm at 6 to 15 mm E32 C...

Страница 6: ...eration indicator orange Between brown and black leads Output transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Reset Operation indicator orange Between blue and black lea...

Страница 7: ...atmospheres or environments that exceed product ratings 6 Do not wire the product incorrectly such as using incorrect power supply polarity 7 Connect the load properly 8 Do not short circuit both end...

Страница 8: ...ection and Disconnection The E3X Amplifier Unit has a lock lever Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures 1 Connection Open the Protective Cove...

Страница 9: ...eparated press down on the lever on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Mounting End Plate PFP M Depending on how i...

Страница 10: ...s Center of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 T...

Страница 11: ...enter of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 Two...

Страница 12: ...lator diameter 1 1 mm Edge of amplifier Slave Connector E3X CN12 7 2 000 50 0 E3X CN12 2 6 dia 2 6 dia cable 1 conductor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator...

Страница 13: ...Description 999 10 times 110 min Stable incident light 100 90 to 110 Unstable incident light or Unstable interrupted light 0 90 max Stable interrupted light Displays 1 Operation indicator Excess gain...

Страница 14: ...MEMO 14...

Страница 15: ...may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control sys...

Страница 16: ...ed OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V...

Страница 17: ...00E E32 T14L E32 CC200 E32 DC200 E32 TC200A E32 C42 E32 D11R E32 D12 E32 D12F E32 D14L E32 D73 E32 DC200B E32 DC200B4 E32 DC200F E32 DC200F4 E32 G14 E32 L25 E32 L25A E32 L25L E32 R21 E32 T11L E32 T14...

Отзывы: