E3NX-FA
□□
Series
●
2-point Tuning
①
Detecting Presence/Absence of Workpiece
Workpiece is present
1-4
Mounting Fiber Unit
2-4
Channel switching
(2-output type: E3NX-FA21, E3NX-FA51, E3NX-FA7TW, E3NX-FA9TW, and E3NX-FA54TW)
Smart Tuning [Easy Sensitivity Setting]
2-5
1-3
Mounting the Amplifier Unit
■
Mounting on DIN Track
■
Removing from DIN Track
DIN Track
Tighten the screw
while pressing the End Plate.
Fiber Unit Connection Side Hook
1
2
3
B
A
4
5
■
Use Fiber Cutter
■
Mount Fiber Unit
・To mount the thin-diameter Fiber Unit, an attachment
(E39-F9) is required.(The attachment is included with
the applicable Fiber Unit.)
When mounting a coaxial reflective Fiber Unit, insert the
single-core Fiber Unit to the upper hole (Emitter side) and the
multi-core Fiber Unit to the lower hole (Receiver side).
(1) Open the cover.
(2) Raise the lock lever.(Release)
(3) Insert the Fiber Unit in the fiber unit hole to the
bottom.
(4) Return the lock lever to the original position and fix
the Fiber Unit.(Lock)
(1)
Insert a Fiber Unit into a fiber cutter hole.
(2)
Press down the blade at a single stroke to cut the
Fiber Unit.
9999
2500
■
OUT Selection Indicator switches to switch the settings.
OUT Selection Indicators (Output 1/Output 2) switch.
2.
Settings
2
●
Maximum Sensitivity Tuning
②
Increasing Resistance to Dust and Dirt
Workpiece is absent
Workpiece
Through-beam:
Workpiece is present
Reflective:
Workpiece is absent
●
Full Auto Tuning
③
Making Adjustment with Moving Workpiece without Stopping the Line
●
Position Tuning
④
Determining the Workpiece Position
●
Percentage Tuning
⑤
Detecting a Transparent or Microscopic Object (Setting a Threshold with Received Light Intensity Ratio)
●
Power Tuning
⑥
Restoring the Received Light Intensity Weakened due to Dust or Dirt / Restoring the Saturated Received Light Intensity
Workpiece
Workpiece
is absent
Workpiece is absent
Workpiece is absent
Percentage tuning setting
ON
per
Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.
Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.
Execution can be done even if the order of workpiece
exists/not exist is reversed.
Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.
Threshold setting: Set the light intensity of approximately 7% when the button pressed.
Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.
Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.
Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.
Threshold setting: Set to the same value as the received light amount Desirable detection position.
Received light intensity setting: Adjusts the light intensity level without the presence of a sensing object to the power tuning level.
Threshold setting: Set to (Light intensity level that has been set according to the setting above x Percentage tuning level).
Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.
Threshold setting: Not changed.
1pnt
2pnt
Release the button when "FULL" appears.
Release the button when the workpiece passed through.
0
0
It will become susceptible to the influence of
background objects.
When percent tuning setting is ON, only power tuning can be performed.
Other tunings cannot be performed.
Adjustment for a reflective type requires the presence of a workpiece.
Both thru-beam and reflective types require the presence of a workpiece
if the setting is made after position tuning.
9999
9999
1pnt
1500
1500
9999
1500
1pnt
+
©
OMRON Corporation 2012-2015 All Rights Reserved.
Smart Fiber Amplifier
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
Protective Label
Power Supply Connecting Terminal
Installation
1
1-1
Dimensions
Dimensions in parentheses () indicates the ones with related components.
The cover could come off if it is tilted by 170 degrees or more.
Input/Output Circuit Diagram
1-2
■E3NX-FA11/FA21/FA6/FA7TW
/FA11-5/FAH11/FAH6(NPN)
■E3NX-FA41/FA51/FA8/FA9TW/FA54TW
/FAH41/FAH8(PNP)
Fiber Cutter E39-F4
(Provided with
the Fiber Unit)
Thin-diameter Fiber
Attachment: E39-F9
Thin-diameter
Fiber Unit Hole x 2
Cover
Fiber Unit
Standard Fiber Unit
Hole (dia. 2.2 mm) x 3
1
3
Single Core
Multi Core
2
4
Lock Lever
Lock
Release
2
1
Workpiece
Workpiece
2-2
Output switching
Press button.
L/D
Reflective: Set to "Light ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns ON.
Through-beam: Set to "Dark ON" to turn the
output ON with a workpiece in the detection area.
[L/D Indicator] turns
ON.
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Hold for 3 seconds or longer
Hold for 7 seconds or longer
Refer to " Detailed Settings".
Hold for 3 seconds or longer
Hold both for 1 sec. or longer
2-3
Minute Adjustment of Threshold Level
UP/DOWN
Hold the key for high-speed level
adjustment.
Press button to adjust
the threshold level.
The threshold level
becomes higher.
The threshold level
becomes lower.
Moving the finger off the button displays "2Pnt".
Moving the finger off the button displays "2Pnt".
Desirable
detection
position
Hold for 1 seconds or longer
(2/4)
Warning Indications
WARNING
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Checking the Package Content
• Amplifier Unit: 1 • Instruction Sheet (this sheet): 1 (Japanese, English, Chinese and Korean
)
The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated
values
(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
· To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power
devices.
· High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in
the same duct may cause induction, resulting in malfunction or damage.
· Do not apply any load exceeding the ratings. Otherwise damage or fire may result.
· Do not short the load. Otherwise damage or fire may result.
· Connect the load correctly.
· Do not miswire such as the polarity of the power supply.
· If you use two or more units connected, always connect all of the units to the same power supply and turn on the power of
them at the same time. Otherwise functions for the connected units may be affected.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient
temperature and the power supply voltage. Attention must be paid during operation or cleaning.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
· Do not use the Sensor in water, rainfall, or outdoors.
· Use the product in the IP54 enclosure.
· UL Standard Certification
Only the sensors with Enhanced UL Certification Mark are certified by UL. They are intended to be supplied by a "Class
2 circuit". When used in United States and Canada, Please use the same Class 2 source for input and output.The
overcurrent protection current rating is 2A max. They were evaluated as Open type and shall be installed within a
enclosure.
· Be sure to mount the unit to the DIN track until it clicks.
· When using a connector type product, place a protective label (provided with the E3X-CN series) on the
power supply connecting terminals that are not used, to prevent electric shock or short circuit.
· The length for the cable extension must be 30 m or less (or less than 10 m for S-mark certified models).Be sure to use a cable
of at least 0.3 mm
2
for extension.The power voltage must be 24 to 30 V when connecting amplifier units with extension cable
and wire-saving connector.
· Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N
· Do not apply excessive force such as tension, compression or torsion to the amplifier unit with the fiber unit fixed to the
amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after the power is turned on
depending on use environment.
· The product is ready to operate 200 ms after the power supply is turned ON.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting in
malfunction of the unit. In such case, increase the threshold.
· The Communication Unit E3X-DRT21-S, E3X-CRT, E3X-ECT and E3NW cannot be connected.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the
product, turn off the power, and consult your dealer.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
· The amplifier unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit
(1,000,000times), the memory error appears, in which case you must replace the amplifier unit.Memory data rewrite occurs
when you perform zero reset, threshod change, tuning and so on.
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
■
Joining Amplifier Units
Up to 30 Amplifier Units can be joined.
Under
environments such as vibration, use an End Plate even
with a single amplifier unit. If mounting the product
without joining the amplifier unit, seal the side optical
communication part with lightproof tape.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
will result in minor or moderate injury, or may result in serious
injury or death.Additionally there may be significant property damage.
DIN track (PFP-
□
N) is sold separately.
Light-ON/Dark-ON can be switched with output 2.(Refer to 2-2)
For Output 2, light intensity is not adjusted during tuning. To adjust power tuning, switch to Output 1.
(1)
Mount the Amplifier Units one at a time onto the DIN track.
(2)
When using a wire-saving connector, mount the master
connector to A and slave connector to B.
(3)
Slide the Amplifier Unit until the Amplifier Unit is closely
attached.(Arrow 3) (For the wire-saving connector type, be
sure that a master connector and a slave connector, or a slave
connector and a slave connector are connected.)
(4)
Use End Plates (PFP-M: separately sold) at the both ends
of the grouped Amplifier Units to prevent them from
separating due to vibration or other cause.(Arrow 4)
(5)
Tighten the screw on the End Plates using a driver.(Arrow 5)
(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while performing step (1).
(1)
Let the hook on the Amplifier Unit's Fiber Unit
connection side catch the track.
(2)
Push the unit until the hook clicks into place.
●
Smart Tuning Error
Error / Display
Cause
Remedy
Near Error
Incident light level is too high.
Incident light level is too low.
Over Error
Low Error
err
err
err
・
Change the detection function to the mode of slower response time.
・
Narrow the distance between emitter and receiver. (Though-beam model)
・
Move the Fiber Head closer to the sensing object. (Reflection model)
・
Widen the distance between emitter and receiver. (Though-beam model)
・
Move the Fiber Head away from the sensing object. (Reflection model)
・
Use a thin-diameter Fiber.
・
Make the distance between emitter and receiver closer. (Through-beam model)
・
Move the Fiber Head closer to the sensing object. (Reflection model)
The light level difference
between Points 1 and 2 are
extremely small.
Blocking ON or Unblocking ON can be set on output 1 and
2 individually.
External input
setting tuning
Batch tuning setting
Percent tuning or
Power percent tuning*
External input
1500
per
1500
per
1500
per
● Batch Tuning
⑦
Tuning the linked amplifier simultaneously
※*Power percent tuning: After power tuning is done, percent tuning is executed.
External input signal
of ch No. 1 unit
Signal input time: 25 ms or longer
The linked units are tuned together.
For the two output type, both output are tuned.
"
⑤
Detailed Settings"
- Tuning type is determined by the batch tuning setting of each unit.
- If a tuning error occurs on either output 1 or 2, the corresponding error is displayed. For
the detailed of the error, refer to "Smart Tuning Errors."
- If setting batch tuning as other than OFF on a unit of ch No. 2 or higher, the external
input function of the unit is not usable.
During or directly after the following operation, tuning cannot be executed. Wait for a
while before executing tuning.
■ Operation disabling tuning:
In the setting mode, tuning, setting initialization, user resetting/saving, sensor OFF,
emission OFF
2-1
Setting and Display Overview
[L/D Indicator
:
Orange]
Displays Light ON/Dark ON setting.
[OUT Indicator
:
Orange]
[OUT Indicator
:
Orange]
[OUT Selection Indicators
:
Orange]
Turns ON when Output is ON.
[DPC Indicator
:
Green]
[ST Indicator
:
Blue]
Performs tuning and [ST Indicator]
turns ON.
Sensitivity Setting
【 】
Button
Setting Reset
Key Lock
Zero Reset
Solution Viewer
L/D
MODE
UP/DOWN
UP
Turns ON when Dynamic Power Control is
effective.
S.TUNE
E3NX-FA21, E3NX-FA7TW
E3NX-FA51, E3NX-FA9TW
E3NX-FA54TW
Green Digital
Display
Threshold Level
White Digital
Display
Incident Light
Level
Minute Threshold
Adjustment
The green digital value
changes.
[UP/DOWN
]
Button
Mode/OUT Switch
[
MODE
]
Button
Switches between SET mode and RUN mode by a
long press (3 seconds or longer) of the key. If pressed
and held for 1 second, OUT is switched (2 outputs).
Output Switch
[
L/D
]
Button
A single press switches between
Light ON/Dark ON. [L/D] Indicator
changes.
+ : Press both
Refer to " Convenient
Setting Features".
L/D
MODE
Lit up when the smart tuning function is effective. Put out
when the detection function is changed or the settings are
initialized.
In the [Detection Mode], press the button.
1.
Dispose of in accordance with WEEE Directive
+
CH3
CH2
CH1
■
E3NX-FA7/FA24(NPN)
■
E3NX-FA9/FA54(PNP)
10 to 30 VDC
0V
Brown
Pink *2
Blue
Black:
Control Output 1
Orange *1
Control Output 2
Load
Load
Overcurrent Protection Circuit
Sensor Main Circuit
10 to 30 VDC
0V
Brown
①
Pink *4
Blue
③
Black:
④
Control Output 1
Orange
②
*3
Control Output 2
Load
Overcurrent Protection Circuit
Sensor Main Circuit
Load
10 to 30 VDC
0V
Brown
①
Orange
②
Blue
③
Black:
④
Control Output 1
Load
Overcurrent Protection Circuit
Sensor Main Circuit
10 to 30 VDC
0V
Brown
①
Orange
②
Blue
③
Black:
④
Control Output 1
Sensor Main Circuit
Load
*1 E3NX-FA21/FA7TW only
*2 E3NX-FA21 only
*3 E3NX-FA51/FA9TW/FA54TW only
*4 E3NX-FA51 only
*①, ②, ③ and ④ are pin terminals of M8 Connector Type
Overcurrent Protection Circuit
External Input
External Input
External Input
External Input
E3NX-FA
□□
Series
Unit: mm
5.1
(16.5)
147.1
(Max. with the protective cover open)
20.5
16
(9.4)
3.4
(37) 33.5 (5.7)
(37.9)
71.8
(20.5)
4.3
170°
(Max. with the protective cover open)
φ4
12.7
104.8
(Max. with the protective cover open)
2-2.4 dia.
10
5.7
4.5
4.8
21.7
5.2
4.2
27.1
10
6.9
(13)
<Wire-saving Connector Type>
<Pre-wired Type>
OPTICAL
COMMUNICATION
POSITION
Mounting bracket E39-L143 (sold separately)
<M8 Connector Type>
①
②
③
④
12.7
10
With an thin-diameter fiber
attachment (E39-F9)
* 9 5 3 1 3 3 5 - 8 D *