E3NX-FA

□□

Series

● 

2-point Tuning

Detecting Presence/Absence of Workpiece

Workpiece is present

1-4

Mounting Fiber Unit

2-4

Channel switching

 (2-output type: E3NX-FA21, E3NX-FA51, E3NX-FA7TW, E3NX-FA9TW, and E3NX-FA54TW)

Smart Tuning [Easy Sensitivity Setting]

2-5

1-3

Mounting the Amplifier Unit

Mounting on DIN Track

Removing from DIN Track

DIN Track

Tighten the screw 

while pressing the End Plate.

Fiber Unit Connection Side Hook

1

2

3

B

A

4

5

Use Fiber Cutter

Mount Fiber Unit

・To mount the thin-diameter Fiber Unit, an attachment 

(E39-F9) is required.(The attachment is included with 

the applicable Fiber Unit.)

When mounting a coaxial reflective Fiber Unit, insert the 

single-core Fiber Unit to the upper hole (Emitter side) and the 

multi-core Fiber Unit to the lower hole (Receiver side).

(1) Open the cover.

(2) Raise the lock lever.(Release)

(3) Insert the Fiber Unit in the fiber unit hole to the 

bottom.

(4) Return the lock lever to the original position and fix 

the Fiber Unit.(Lock)

(1) 

Insert a Fiber Unit into a fiber cutter hole.

(2) 

Press down the blade at a single stroke to cut the 

Fiber Unit.

9999

2500

OUT Selection Indicator switches to switch the settings.

OUT Selection Indicators (Output 1/Output 2) switch.

2.

Settings

2

● 

Maximum Sensitivity Tuning

Increasing Resistance to Dust and Dirt

Workpiece is absent

Workpiece

Through-beam:

Workpiece is present

Reflective:

Workpiece is absent

● 

Full Auto Tuning

Making Adjustment with Moving Workpiece without Stopping the Line

● 

Position Tuning

Determining the Workpiece Position

● 

Percentage Tuning

Detecting a Transparent or Microscopic Object (Setting a Threshold with Received Light Intensity Ratio)

● 

Power Tuning

Restoring the Received Light Intensity Weakened due to Dust or Dirt / Restoring the Saturated Received Light Intensity

Workpiece

Workpiece 

is absent

Workpiece is absent

Workpiece is absent

Percentage tuning setting

ON

per

Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.

Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.

Execution can be done even if the order of workpiece 

exists/not exist is reversed.

Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.

Threshold setting: Set the light intensity of approximately 7% when the button pressed.

Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.

Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.

Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.

Threshold setting: Set to the same value as the received light amount Desirable detection position.

Received light intensity setting: Adjusts the light intensity level without the presence of a sensing object to the power tuning level.

Threshold setting: Set to (Light intensity level that has been set according to the setting above x Percentage tuning level).

Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.

Threshold setting: Not changed.

1pnt

2pnt

Release the button when "FULL" appears.

Release the button when the workpiece passed through.

   0

   0

It will become susceptible to the influence of 

background objects.

When percent tuning setting is ON, only power tuning can be performed. 

Other tunings cannot be performed.

Adjustment for a reflective type requires the presence of a workpiece.

Both thru-beam and reflective types require the presence of a workpiece

if the setting is made after position tuning.

9999

9999

1pnt

1500

1500

9999

1500

1pnt

© 

OMRON Corporation  2012-2015  All Rights Reserved.

Smart Fiber Amplifier

INSTRUCTION SHEET

Thank you for selecting an OMRON product. This sheet 

primarily describes precautions

required in installing and operating the product.

• A specialist who has the knowledge of electricity must treat 

the product. 

• Please read this manual carefully, and use it correctly after 

thoroughly understanding the product. 

• Please keep this manual properly for future reference 

whenever it is necessary.

Protective Label

Power Supply Connecting Terminal

Installation

1

1-1

Dimensions

Dimensions in parentheses () indicates the ones with related components.

The cover could come off if it is tilted by 170 degrees or more.

Input/Output Circuit Diagram

1-2

■E3NX-FA11/FA21/FA6/FA7TW

 /FA11-5/FAH11/FAH6(NPN)

■E3NX-FA41/FA51/FA8/FA9TW/FA54TW

 /FAH41/FAH8(PNP)

Fiber Cutter E39-F4 

(Provided with 

 the Fiber Unit)

Thin-diameter Fiber 

Attachment: E39-F9

Thin-diameter 

Fiber Unit Hole x 2

Cover

Fiber Unit

Standard Fiber Unit 

Hole  (dia. 2.2 mm) x 3

1

3

Single Core

Multi Core

2

4

Lock Lever

Lock

Release

2

1

Workpiece

Workpiece

2-2

Output switching

Press     button.

L/D

Reflective: Set to "Light ON" to turn the

output ON with a workpiece in the detection area.

[L/D Indicator]  turns          ON.

Through-beam: Set to "Dark ON" to turn the 

output ON with a workpiece in the detection area.

[L/D Indicator]  turns

   

ON.

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Hold for 3 seconds or longer

Hold for 7 seconds or longer

 Refer to "     Detailed Settings".

Hold for 3 seconds or longer

Hold both for 1 sec. or longer

2-3

Minute Adjustment of Threshold Level

UP/DOWN

Hold the key for high-speed level 

adjustment.

Press            button to adjust 
the threshold level.

The threshold level 

becomes higher.

The threshold level 

becomes lower.

Moving the finger off the button displays "2Pnt". 

Moving the finger off the button displays "2Pnt". 

Desirable 

detection 

position

Hold for 1 seconds or longer

(2/4)

Warning Indications

WARNING

Do not use the product with voltage in excess of the rated voltage.

Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply. Otherwise, 

explosion may result.

PRECAUTIONS FOR SAFE USE

PRECAUTIONS FOR CORRECT USE

Checking the Package Content

• Amplifier Unit: 1      • Instruction Sheet (this sheet): 1 (Japanese, English, Chinese and Korean

 

)

The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire.

· Do not install the product in the following locations.

  (1) Locations subject to direct sunlight

  

(2) Locations subject to condensation due to high humidity

  (3) Locations subject to corrosive gas

   

(4) Locations subject to vibration or mechanical shocks exceeding the rated 

values

  (5) Locations subject to exposure to water, oil, chemicals

  

(6) Locations subject to steam

  (7) Locations subjected to strong magnetic field or electric field

· Do not use the product in environments subject to flammable or explosive gases.

· Do not use the product in any atmosphere or environment that exceeds the ratings.

· To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power 

devices.

· High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in 

the same duct may cause induction, resulting in malfunction or damage.

· Do not apply any load exceeding the ratings. Otherwise damage or fire may result.

· Do not short the load. Otherwise damage or fire may result.

· Connect the load correctly.

· Do not miswire such as the polarity of the power supply.

· If you use two or more units connected, always connect all of the units to the same power supply and turn on the power of 

them at the same time. Otherwise functions for the connected units may be affected.

· Do not use the product if the case is damaged.

· Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient 

temperature and the power supply voltage. Attention must be paid during operation or cleaning.

· When setting the sensor, be sure to check safety such as by stopping the equipment.

· Be sure to turn off the power supply before connecting or disconnecting wires.

· Do not attempt to disassemble, repair, or modify the product in any way.

· When disposing of the product, treat it as industrial waste.

· Do not use the Sensor in water, rainfall, or outdoors.

· Use the product in the IP54 enclosure.

· UL Standard Certification

  Only the sensors with Enhanced UL Certification Mark are certified by UL. They are intended to be supplied by a "Class 

2 circuit". When used in United States and Canada, Please use the same Class 2 source for input and output.The 

overcurrent protection current rating is 2A max.  They were evaluated as Open type and shall be installed within a 

enclosure.

· Be sure to mount the unit to the DIN track until it clicks.

· When using a connector type product, place a protective label (provided with the E3X-CN series) on the 

power supply connecting terminals that are not used, to prevent electric shock or short circuit.

· The length for the cable extension must be 30 m or less (or less than 10 m for S-mark certified models).Be sure to use a cable 

of at least 0.3 mm

2

 for extension.The power voltage must be 24 to 30 V when connecting amplifier units with extension cable 

and wire-saving connector.

· Do not apply the forces on the cord exceeding the following limits:

Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N

· Do not apply excessive force such as tension, compression or torsion to the amplifier unit with the fiber unit fixed to the 

amplifier unit.

· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.

· It may take time until the received light intensity and measured value become stable immediately after the power is turned on 

depending on use environment.

· The product is ready to operate 200 ms after the power supply is turned ON.

· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.

· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.

· If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting in 

malfunction of the unit. In such case, increase the threshold.

· The Communication Unit E3X-DRT21-S, E3X-CRT, E3X-ECT and E3NW cannot be connected.

· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the 

product, turn off the power, and consult your dealer.

· Do not use thinner, benzine, acetone, and lamp oil for cleaning.

· The amplifier unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit 

(1,000,000times), the memory error appears, in which case you must replace the amplifier unit.Memory data rewrite occurs 

when you perform zero reset, threshod change, tuning and so on.

This product is not designed or rated for ensuring safety of persons 

either directly or indirectly. Do not use it for such purpose.

Joining Amplifier Units

Up to 30 Amplifier Units can be joined. 

Under 

environments such as vibration, use an End Plate even 

with a single amplifier unit. If mounting the product 

without joining the amplifier unit, seal the side optical 

communication part with lightproof tape.

WARNING

Indicates a potentially hazardous situation which, if not avoided, 

will result in minor or moderate injury, or may result in serious 

injury or death.Additionally there may be significant property damage. 

DIN track (PFP-

N) is sold separately.

Light-ON/Dark-ON can be switched with output 2.(Refer to 2-2)

For Output 2, light intensity is not adjusted during tuning. To adjust power tuning, switch to Output 1. 

(1) 

Mount the Amplifier Units one at a time onto the DIN track.

(2) 

When using a wire-saving connector, mount the master 

connector to A and slave connector to B.

(3) 

Slide the Amplifier Unit until the Amplifier Unit is closely 

attached.(Arrow 3) (For the wire-saving connector type, be 

sure that a master connector and a slave connector, or a slave 

connector and a slave connector are connected.)

(4) 

Use End Plates (PFP-M: separately sold) at the both ends 

of the grouped Amplifier Units to prevent them from 

separating due to vibration or other cause.(Arrow 4)

(5) 

Tighten the screw on the End Plates using a driver.(Arrow 5)

(1) Push the unit in the direction 1.

(2) Lift the unit in the direction of arrow 2 while performing step (1).

(1) 

Let the hook on the Amplifier Unit's Fiber Unit

     connection side catch the track. 

(2) 

Push the unit until the hook clicks into place.

Smart Tuning Error

Error / Display

Cause

Remedy

Near Error

Incident light level is too high.

Incident light level is too low.

Over Error

Low Error

err

err

err

Change the detection function to the mode of slower response time.

Narrow the distance between emitter and receiver. (Though-beam model)

Move the Fiber Head closer to the sensing object. (Reflection model)

Widen the distance between emitter and receiver. (Though-beam model)

Move the Fiber Head away from the sensing object. (Reflection model)

Use a thin-diameter Fiber.

Make the distance between emitter and receiver closer. (Through-beam model)

Move the Fiber Head closer to the sensing object. (Reflection model)

The light level difference 

between Points 1 and 2 are 

extremely small.

Blocking ON or Unblocking ON can be set on output 1 and 

2 individually.

External input

setting tuning

Batch tuning setting

Percent tuning or

Power percent tuning*

External input

1500

per

1500

per

1500

per

● Batch Tuning

Tuning the linked amplifier simultaneously

※*Power percent tuning: After power tuning is done, percent tuning is executed.

External input signal 

of ch No. 1 unit

Signal input time: 25 ms or longer

The linked units are tuned together.

For the two output type, both output are tuned.

"

 Detailed Settings"

- Tuning type is determined by the batch tuning setting of each unit.

- If a tuning error occurs on either output 1 or 2, the corresponding error is displayed. For 

the detailed of the error, refer to "Smart Tuning Errors."

- If setting batch tuning as other than OFF on a unit of ch No. 2 or higher, the external 

input function of the unit is not usable.

During or directly after the following operation, tuning cannot be executed. Wait for a 

while before executing tuning.  

■ Operation disabling tuning:

In the setting mode, tuning, setting initialization, user resetting/saving, sensor OFF, 

emission OFF

2-1

Setting and Display Overview

[L/D Indicator

Orange] 

Displays Light ON/Dark ON setting.

[OUT Indicator

Orange]

[OUT Indicator

Orange]

[OUT Selection Indicators

Orange]

Turns ON when Output is ON.

[DPC Indicator

Green]

[ST Indicator

Blue]

Performs tuning and [ST Indicator] 

turns ON.

Sensitivity Setting

【    】

 

Button

Setting Reset

Key Lock

Zero Reset

Solution Viewer

L/D

MODE

UP/DOWN

UP

Turns ON when Dynamic Power Control is

effective.

S.TUNE

E3NX-FA21, E3NX-FA7TW

E3NX-FA51, E3NX-FA9TW

E3NX-FA54TW

Green Digital

Display

Threshold Level

White Digital

Display

Incident Light

Level

Minute Threshold 

Adjustment

The green digital value 

changes.

[UP/DOWN

Button

Mode/OUT Switch

[

MODE

]

Button

Switches between SET mode and RUN mode by a 

long press (3 seconds or longer) of the key. If pressed 

and held for 1 second, OUT is switched (2 outputs).

Output Switch

[

L/D

Button

A single press switches between 

Light ON/Dark ON. [L/D] Indicator 

changes.

+ : Press both

 Refer to "     Convenient 

 Setting Features".

L/D

MODE

Lit up when the smart tuning function is effective. Put out 

when the detection function is changed or the settings are 

initialized.

In the [Detection Mode], press the         button.

1.

Dispose of in accordance with WEEE Directive

+

CH3

CH2

CH1

E3NX-FA7/FA24(NPN)

E3NX-FA9/FA54(PNP)

10 to 30 VDC

0V

Brown

Pink *2

Blue

Black:

Control Output 1
Orange *1

Control Output 2

Load

Load

Overcurrent Protection Circuit

Sensor Main Circuit

10 to 30 VDC

0V

Brown

Pink *4

Blue

Black:

Control Output 1
Orange 

*3

Control Output 2

Load

Overcurrent Protection Circuit

Sensor Main Circuit

Load

10 to 30 VDC

0V

Brown

Orange

Blue

Black:

Control Output 1

Load

Overcurrent Protection Circuit

Sensor Main Circuit

10 to 30 VDC

0V

Brown

Orange

Blue

Black:

Control Output 1

Sensor Main Circuit

Load

*1 E3NX-FA21/FA7TW only

*2 E3NX-FA21 only

*3 E3NX-FA51/FA9TW/FA54TW only

*4 E3NX-FA51 only

*①, ②, ③ and ④ are pin terminals of M8 Connector Type

Overcurrent Protection Circuit

External Input

External Input

External Input

External Input

E3NX-FA

□□

Series

Unit: mm

5.1

(16.5)

147.1

(Max. with the protective cover open)

20.5

16

(9.4)

3.4

(37) 33.5 (5.7)

(37.9)

71.8

(20.5)

4.3

170°

(Max. with the protective cover open)

φ4

12.7

104.8

(Max. with the protective cover open)

2-2.4 dia.

10

5.7

4.5

4.8

21.7

5.2

4.2

27.1

10

6.9

(13)

<Wire-saving Connector Type>

<Pre-wired Type>

OPTICAL

COMMUNICATION 

POSITION

Mounting bracket E39-L143 (sold separately)

<M8 Connector Type>

12.7

10

With an thin-diameter fiber 

attachment (E39-F9) 

* 9 5 3 1 3 3 5 - 8 D *

Содержание E3NX-FA21

Страница 1: ...IN E3X CN 30m S 10m 0 3mm2 24 30V 40N 0 1N m 20N 29 4N 200ms E3X MC11 E3X MC11 SV2 E3X MC11 S E3C E2C E3X E3X DRT21 S E3X CRT E3X ECT E3NW EEPROM 100 30 1 DIN 2 A B 3 4 PFP M 5 B A 2 Light ON Dark ON...

Страница 2: ...0ms 0 1ms 99 99 1 6 MODE UP DOWN ban ban ban per Eco on 10 Eco Lo 10 MODE n UP DOWN 17 EEPROM ON OFF 1 2 OUT A 0P 100P 1P 50P 300ms DPC EEPROM MODE UP DOWN e st init USE err func cfdr 150p a 2000 8000...

Страница 3: ...the IP54 enclosure UL Standard Certification Only the sensors with Enhanced UL Certification Mark are certified by UL They are intended to be supplied by a Class 2 circuit When used in United States a...

Страница 4: ...d then the indicators All turn ON with low brightness 5 When the number of connected units is 11 or more the ambient temperature is less than 50 h Suitability for Use s Omron Companies shall not be re...

Страница 5: ...0 3mm 24 30V 40N 0 1N m 20N 29 4N 200ms E3X MC11 E3X MC11 SV2 E3X MC11 S E3C E2C E3X E3X DRT21 S E3X CRT E3X ECT E3NW EEPROM 100 IP54 UL UL Class 2 Class 2 2A 1 DIN 2 A B 3 3 4 PFP M 4 5 5 DIN PFP N B...

Страница 6: ...20g 115g 75g 200g 160g 115g 75g 115g 75g 200g 160g 60g 20g 60g 20g 2 2 1 S TUNE ON OFF 25ms NPN PNP ON 0V 1mA OFF Vcc ON Vcc 3mA OFF 0V ON 1 5V 1mA OFF Vcc 1 5V Vcc 0 1mA ON Vcc 1 5V Vcc 3mA OFF 1 5V...

Страница 7: ...MC11 S E3C E2C E3X E3X DRT21 S E3X CRT E3X ECT E3NW EEPROM 100 AC 30 UP DOWN OUT 3 1 2 MODE L D ON Dark ON L D ST S TUNE 1 2 Near Error Over Error Low Error 2 Light ON Dark ON 2 2 2 1 L D 1 2 2 2 L D...

Страница 8: ...1 5V 1mA OFF Vcc 1 5V Vcc 0 1mA ON Vcc 1 5V Vcc 3mA OFF 1 5V 0 1mA 2 1 ON 9ms OFF 20ms NPN PNP E3NX FA21 E3NX FA51 2 1 E3NX FA6 E3NX FA8 1 E3NX FA7 E3NX FA9 1 1 E3NX FA7TW E3NX FA9TW 2 2m 5m 65g 25g E...

Отзывы: