E3NC-LA0
Protective Cap
©
OMRON Corporation 2013 All Rights Reserved.
Smart Laser Amplifier
E3NC-LA0
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
Compatible Communication Unit (Sold Separately)
E3NW Series Communication Unit, Distribution unit E3NW-DS
Installation
1
1-1
Dimensions
1-2
Mounting the Amplifier Unit
Unit: mm
Dimensions in parentheses () indicates the ones with related components.
The cover could come off if it is tilted by 152 degrees or more.
2.6
32.1
16
9.4
37
49.5
4.3
33.5
3.4
159.7
(Max. with the protective cover open)
152°
(Max. with the protective cover open)
39.5
102.4
29.9
26
30.2
5.2
4.2
27.8
10
6.9
DIN Track
Tighten the screw while pressing the End Plate.
Fiber Unit Connection Side Hook
1
2
3
4
5
2
1
Up to 30 Amplifier Units can be connected to
E3NW Series Communication Unit.
Under environments such as vibration, use an End Plate
even with a single amplifier unit.
■
Mounting on DIN Track
(1)
Let the hook on the Amplifier Unit's Sensor Head
connection side catch the track.
(2)
Push the unit until the hook clicks into place.
■
Removing from DIN Track
(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while
performing step (1).
1-3
Mounting the sensor head
Settings
2
Smart Tuning [Easy Sensitivity Setting]
2-4
2-1
Setting and Display Overview
[L/D Indicator
:
Orange]
Displays Light ON/Dark ON setting.
[OUT Indicator
:
Orange]
Turns ON when Output is ON.
[DPC Indicator
:
Green]
[ST Indicator
:
Blue]
Turns ON when Smart Tuning is in progress.
Turns ON when Dynamic Power Control is
effective.
[OUT Selection Indicators
:
Orange]
Green Digital Display
Threshold Level
White Digital
Incident Light
Level
(2/3)
PRECAUTIONS ON SAFETY
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Checking the Package Content
• Amplifier Unit: 1 • Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)
The following precautions must be observed to ensure safe operation of the product. Doing so may cause
damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
· To secure the safety of operation and maintenance, do not install the product close to high-voltage
devices and power devices.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such
as the ambient temperature and the power supply voltage. Use caution when operating or cleaning the
product.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
· Do not miswire such as the polarity of the power supply.
· Be sure to mount the unit to the DIN track until it clicks.
· To prevent electric shock or short circuit, put a protection cap on unused connection power supply
terminals.
· Do not apply excessive force (9.8N max.) such as tension, compression or torsion to the connector of the
sensor head that is fixed to the amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after
the power is turned on depending on use environment.
· The product is ready to operate 200 ms after the power supply is turned ON.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work
properly, resulting in malfunction of the unit. In such case, increase the threshold.
· Sensor communication unit E3NW can be used. E3X-DRT21-S and E3X-CRT/ECT cannot be used.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke,
immediately stop using the product, turn off the power, and consult your dealer.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
114
(Max. with the protective cover open)
10
5
19.2
3.9
11.5
13.8
■
Joining Amplifier Units
(1)
Mount the Amplifier Units one at a time onto the DIN track.
Slide the Amplifier Unit until the communication connector is
closely attached.(Arrow 3)
(2)
Use End Plates (PFP-M: separately sold) at the both
ends of the grouped Amplifier Units to prevent them from
separating due to vibration or other cause.(Arrow 4)
(3)
Tighten the screw on the End Plates using a driver.(Arrow 5)
Open the protection cover.
Fix the sensor head with M3 screws.
Apply tightening torque of 0.5N・m for fixing.
1.
2.
Lock Lever
Connector cover: Blue
Setting Reset
Key Lock
Zero Reset
Solution Viewer
L/D
L/D
MODE
MODE
UP/DOWN
UP
+:
Press both
Refer to " Convenient
Setting Features".
Performs tuning and [ST Indicator]
turns ON.
Sensitivity Setting
【 】
Button
S.TUNE
Minute Threshold
Adjustment
The green digital value
changes.
[UP/DOWN
]
Button
Output Switch
[
L/D
]
Button
A single press switches between
Light ON/Dark ON. [L/D] Indicator
changes.
Mode/OUT Switch
[
MODE
]
Button
Switches between SET mode and RUN mode by a
long press (3 seconds or longer) of the key. If Push
short, OUT is switched.
For settings with the Communication Unit,
refer to the User's Manual that comes with the Communication Unit.
2-2
Switching Control Output
2-3
Sensor Head Display
Set to "Dark ON" to turn ON the output without a sensing object.
[L/D Indicator] turns ON.
[STABILITY Indicator: Green]
Turns ON when output is stable.
[OUT Indicator
:
Orange]
Turns ON when Output is ON.
Press button.
L/D
Set to "Light ON" to turn the output ON with a workpiece in the detection area.
[L/D Indicator] turns ON.
Stable indication
(Green)
ON
OFF
ON
ON
OFF
OFF
ON
Operation indication (Orange)
L
•
ON
D
•
ON
Stable
operation
area
Stable
operation
area
Unstable
operation
area
Operation
level
Operation
level x1.1
Operation
level x0.9
Workpiece
ON
OFF
ON
OFF
Output
for Light-on
Output
for Dark-on
Light intensity
level
*
*
*
Setting to the stable area makes the operation more reliable against the
environmental changes (temperature, voltage, dust, setting deviation) after
installation. Be careful on environmental changes when using the sensor in an
application in which stable area cannot be obtained.
*
2-6
Minute Adjustment of Threshold Level
●
Smart Tuning Error
UP/DOWN
Hold the key for high-speed
level adjustment.
Press button to adjust
the threshold level.
The threshold level
becomes higher.
The threshold level
becomes lower.
Error / Display / Cause
Remedy
Error Origin Tuning Type
2-point Tuning
Full Auto Tuning
Positioning Tuning
All
Other than maximum
sensitivity tuning
The light level difference
between Points 1 and 2 are
extremely small.
Incident light level is too
high.
Incident light level is too low.
Near Error
Over Error
Low Error
・Change the detection function to the mode of slower response time.
・Move the Sensor Head closer to the sensing object.
・Move the Sensor Head away from the sensing object.
・Move the Sensor Head closer to the sensing object.
err
err
err
●
2-point Tuning
Basic Setting
Workpiece is present
2-5
Output switching
9999
■
OUT Selection Indicator switches to switch the settings.
Push short the [MODE] button in [Measurement Mode].
OUT Selection Indicators (Output 1/Output 2) switch.
1.
2.
OUT Selection Indicator (Output 1)
[Output 1]
OUT Selection Indicator (Output 2)
Push short the [MODE] button in [Measurement Mode].
[Output 2]
●
Maximum Sensitivity Tuning
Enhancing Durability of the Head against Dust and Stain
Workpiece is absent
Workpiece is absent
●
Full Auto Tuning
Setting for a Moving Workpiece
●
Position Tuning
Setting to Detect by Workpiece Position
●
Percentage Tuning
Detecting a Transparent or Microscopic Object
●
Power Tuning
Initializing Light Intensity Changed Due to Dust or Dirt
Workpiece
is absent
Workpiece is absent
Percentage tuning setting
ON
per
Execution can be done even if the order of workpiece
exists/not exist is reversed.
1pnt
1pnt
0
0
9999
9999
1pnt
1500
9999
5000
1500
2500
2pnt
Workpiece
Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.
Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.
Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.
Threshold setting: Set the light intensity of approximately 7% when the button is pressed.
Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.
Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.
Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.
Threshold setting: Set to the same value as the received light amount Desirable detection position.
Received light intensity setting: Adjust it to the received light intensity or power tuning level without detection object.
Threshold setting: Light amount without a workpiece x (1 + Percentage tuning level)
Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.
Threshold setting: Not changed.
When percent tuning setting is ON, only power tuning
can be performed. Other tunings cannot be performed.
L/D switching can be performed on Output 2 as well.(Refer to 2-2)
It will become susceptible to the influence of
background objects.
Desirable
detection
position
+
Moving the finger off the button displays "2Pnt".
Moving the finger off the button displays "2Pnt".
Workpiece
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
Hold for 3 seconds or longer
Release the button when "FULL" appears.
Hold for 7 seconds or longer
Release the button when the workpiece passed through.
Refer to " Detailed Settings".
Hold for 3 seconds or longer
Hold both for 1 sec. or longer
・
Do not touch the emitter and receiver
areas of the sensor head.
A fingerprint may prevent proper
measurement.
If you accidentally touch it, use a soft
cloth to wipe it out.
・
Fix the connector area so that it should
not be affected by oscillation and
impact.
Hold for 1 seconds or longer
OPTICAL COMMUNICATION
POSITION
DIN Track
SOLD SEPARATELY
PFP-□-N
Insert the sensor head, with the lock lever on
its connector area facing upward, all the way
into the connector port.
The color of the connector cover for E3NC-LH
is blue.
Make sure to avoid misconnection by
confirming the cover color in advance.
To remove it, press and hold the lock lever
then pull the sensor head out.
Meanings of Signal Words
Warning Indications
WARNING
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or in property damage.
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
WARNING
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
*
4 0 1
3
2 9 8
-
2
C *
Tuning with regressive reflection is not recommended as the variation of the light values may occur, resulting in malfunction of the product.
Diffuse reflection: Perform tuning with the presence of a
sensing object.
Regressive reflection: Perform tuning without the
presence of a sensing object.
After positioning tuning performed, a sensing object must
be present for both diffuse and regressive reflections.