manualshive.com logo in svg
background image

12

Standard Photoelectric Sensors

WARRANTY

OMRON’s exclusive warranty is that the products are free from de-
fects in materials and workmanship for a period of one year (or other
period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EX-
PRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MER-
CHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT 
THE BUYER OR USER ALONE HAS DETERMINED THAT THE 
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF 
THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDI-
RECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR 
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE 
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, 
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the in-
dividual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRAN-
TY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS 
UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PROD-
UCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND 
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, 
MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT 
SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR EN-
SURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED 
UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE 
FOR SUCH PURPOSES. Please refer to separate catalogs for OM-
RON's safety rated products.

OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of products in the

customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use that
apply to the products. This information by itself is not sufficient for a
complete determination of the suitability of the products in combina-
tion with the end product, machine, system, or other application or
use.

The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
of all possible uses of the products, nor is it intended to imply that the
uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or

electrical interference, or conditions or uses not described in this
document.

• Nuclear energy control systems, combustion systems, railroad sys-

tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate in-
dustry or government regulations.

• Systems, machines, and equipment that could present a risk to life

or property.

Please know and observe all prohibitions of use applicable to the
products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for
the user in determining suitability and does not constitute a warranty.
It may represent the result of OMRON’s test conditions, and the users
must correlate it to actual application requirements. Actual perfor-
mance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time
based on improvements and other reasons.

It is our practice to change model numbers when published ratings or
features are changed, or when significant construction changes are
made. However, some specifications of the product may be changed
without any notice. When in doubt, special model numbers may be as-
signed to fix or establish key specifications for your application on
your request. Please consult with your OMRON representative at any
time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for man-
ufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is
believed to be accurate; however, no responsibility is assumed for
clerical, typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a pro-
grammable product, or any consequence thereof.

In the interest of product improvement, specifications are subject to change without notice.

Cat. No. E59E-EN-01

OMRON EUROPE B.V.

Wegalaan 67-69, 
NL-2132 JD, Hoofddorp,  
The Netherlands
Phone: +31 23 568 13 00
Fax:

+31 23 568 13 88

www.industrial.omron.eu

Содержание E3F2-7B4-M1-S

Страница 1: ...gth please contact your OMRON sales representative Sensing method Sensing distance Connection method Order code PNP output NPN output Through beam 7 m 2 m 1 1 Pre wired connectors are available on request Contact your OMRON representative E3F2 7B4 S 2M E3F2 7C4 S 2M 1 E3F2 7B4 M1 S E3F2 7C4 M1 S Retro reflective with M S R 2 2 Order reflector separately 0 1 to 4 m adjustable 3 3 Measured with E39 ...

Страница 2: ...0 x 40 mm enhanced chemical resistance 5 m 100 mm E39 R7 84 mm 6 m 100 mm E39 R8 100 x 100 mm 5 m 100 mm E39 R40 80 x 80 mm Tape Reflectors 0 7 m 150 mm E39 RS1 35 x 10 mm 1 1 m 150 mm E39 RS2 35 x 40 mm 1 4 m 150 mm E39 RS3 80 x 70 mm Lens Cap E39 F31 Mounting Bracket Y92E B18 screw mount Cord Shape Cable type Model Standard Straight 2 m Four wire type M12 connector XS2F D421 D80 A 5 m XS2F D421 ...

Страница 3: ...een energized parts and case Vibration resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hrs each direction X Y Z Shock resistance Destruction 500 m s2 each direction X Y Z Degree of protection 1 1 The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure steam cleaning During the test 14 16l min water at 80 C is sprayed onto the sensor from different angles with 8000 ...

Страница 4: ...pical sensing distance E39 RS3 E39 R1S E39 R40 E39 R7 E39 R8 20 40 60 80 100 120 0 0 5 10 15 5 10 15 Distance Y mm Distance X mm 140 white paper 50 x 50 mm X Y Object 100 200 300 400 500 600 0 0 10 20 30 40 10 20 30 40 Distance Y mm Distance X mm Sensing distance adjustable between 0 and 550 mm Sensitivity adjusted to maximum Sensitivity adjusted to 400 mm white paper 100 x 100 mm X Y Object 2 4 6...

Страница 5: ...0 1000 0 100 10 1 0 1 Excess gain Distance X mm Grey paper 18 reflectivity White paper 90 reflectivity Sensitivity adjusted to maximum Sensing object 100 x 100 mm 0 2 4 6 0 50 100 150 Distance mm Spot diameter mm 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence movement 20 00 10 00 0 00 10 00 20 00 40 30 20 10 0 10 20 30 40 Incline Angle Sensing Distence moveme...

Страница 6: ...lack XS2F D42 D80 XS2F G42 G80 Main circuit 1 2 3 4 1 3 Connector Pin Arrangement 10 to 30 VDC 0 V Brown Blue Power indicator red Incident Interrupted ON OFF ON OFF Operate Release Output indicator red Output transistor Load relay Light indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD ZD VZ 36 V Stability ...

Страница 7: ... OFF Operate Release Output indicator orange Output transistor Load relay Output indicator Stability indicator Orange Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD ZD VZ 36 V Green Incident Interrupted ON OFF ON OFF Operate Release Output indicator orange Output transistor Load relay Output indicator Stability indica...

Страница 8: ...ngement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink ZD VZ 36 V Stability indicator Green Only on models E3F2 R4C4 and E3F2 D1C4 Incident Interrupted ON OFF ON OFF Operate Release Output indicator red Output transistor Load relay Output indicator Red Main circuit 1 2 3 4 1 2 3 4 Connector Pin Arrangement 10 to 30 VDC 100 mA max Load 0 V Mode selection Brown Black Blue Pink...

Страница 9: ... E39 R1S E39 R7 4 8 dia 37 42 3 64 9 Light indicator 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 Light indicator 4 8 dia 76 16 4 dia M12x1 6g 4 M18x1 6g 24 27 7 6 2 65 5 optical area 37 42 3 49 3 64 9 Light indicator Sensitivity adjustor 4 8 dia 16 4 dia 4 dia 4 M18x1 6g 24 27 7 6 2 optical area 37 42 3 49 3 Light indicator Sensitivity adjustor 4 8 dia 16 4 dia M12x1 6g 4 M18x1 6g 7...

Страница 10: ... Y92E B18 Note Hexagon bolt M5 x 32 Material plastic Lens Cap E39 F31 Reflectors f for M3 for M3 9 100 100 92 92 for M3 8 7 84 5 84 5 77 77 80 4 R1 70 0 6 Adhesive tape side 35 10 0 7 Adhesive tape Reflecting surface 4 x R1 40 35 0 7 Adhesive tape Reflecting surface 4 x R1 20 dia 4 max Metal rim Gasket E3F2 Glass plate ...

Страница 11: ...nlight 2 Locations subject to condensation due to high humidity 3 Locations subject to corrosive gas 4 Locations where the Sensor may receive direct vibration or shock Connecting and Mounting 1 The maximum power supply voltage is 30 VDC Before turning the power ON make sure that the power supply voltage does not exceed the maximum voltage 2 Laying Sensor wiring in the same conduit or duct as high ...

Страница 12: ...listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad sys tems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate in dustry or government regulation...

Отзывы: