A-457

E3C-LDA Series

E3C-L

DA Series

Amplifier Units

*1:

Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communications
function for the Mobile Console will not function.

*2:

The preset counter is available only with advanced, external-input models.

Nomenclature

Type

Advanced, twin-output models

Advanced, external-input models

Model NPN output

E3C-LDA11

E3C-LDA6

E3C-LDA21

E3C-LDA7

Item

PNP output

E3C-LDA41

E3C-LDA8

E3C-LDA51

E3C-LDA9

Supply voltage

12 to 24 VDC 

±

10%, ripple (p-p) 10% max.

Power consumption

1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)

Control output

Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector

Load current: 50 mA max.; residual voltage: 1 V max.

Response 

time

Super-high-speed mode

100 

µ

s for operation and reset

80 

µ

s for operation and reset

Standard mode

1 ms for operation and reset

High-resolution mode

4 ms for operation and reset

Functions

Power tuning, differential detection, timer, zero-reset, initial reset, mutual interference prevention (See note 1.), preset 

counter (See note 2.), reversed display

I/O settings

Output setting (Select from channel 2 output, area output, or 

self-diagnosis.)

External input setting (Select from teaching, power tuning, 

zero reset, light OFF, or counter reset.) 

Display

Operation indicator for channel 1 (orange), operation indica-

tor for channel 2 (orange)

Operation indicator (orange), Power Tuning indicator (orange)

Digital display

Select from the following: Incident level + threshold, incident 
level perc threshold, incident light peak level + no in-
cident light bottom level, minimum incident light peak level + 
maximum no incident light bottom level, long bar display, in-
cident level + peak hold, incident level + channel

Select from same displays as given at the left or a counter dis-

play.

Ambient illumination

(receiver side)

Incandescent lamp:10,000 lux max.

Sunlight:20,000 lux max.

Ambient temperature

Operating:Groups of 1 to 2 Amplifiers: 

25

°

C to 55

°

C

Groups of 3 to 11 Amplifiers: 

25

°

C to 50

°

C

Groups of 12 to 16 Amplifiers: 

25

°

C to 45

°

C

(with no icing or condensation)

Storage: 

30

°

C to 70

°

C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Connection method

Prewired 

cable

Separate connector

Prewired 

cable

Separate connector

Weight (packed state)

Approx. 100 g

Approx. 55 g

Approx. 100 g

Approx. 55 g

Materials

Case

Polybutylene terephthalate (PBT)

Cover

Polycarbonate

UP

SET

RUN

1

2

DOWN

MODE

L

D

1    Operation indicator

2    Main display (red)

3    Twin-output Models: Operation indicator for channel 2 
      External-input Models: Power tuning indicator

4    Sub-display (green)

7    Operation keys

5    SET/RUN switch

6    Twin-output Models: Channel selector
      External-input Models: Operation mode selector

    Lit when the output is ON.
     Twin-output Models: Lit when the output for channel 1 is ON.

 

2

   Displays the incident light level or the function name.

 

3

 

  Twin-output Models: Lit when the output for channel 2 is ON.

      External-input Models: Lit when power tuning is set.

 

4

 

  Displays supplemental detection information, the setting of a function, etc.

 5

 

  Used to switch the mode.

 6

 

  Twin-output Models: Used to select the channel to display or set.

     External-input Models: Used to select dark-ON or light-ON operation

 7

  

 Used to change the display, set functions, etc.

1

1

Содержание E39-P31

Страница 1: ...od Focus Model number Remarks Diffuse reflective Spot E3C LD11 Mounting a Beam Unit sold separately allows the use of line and area beams Line E3C LD21 This model number is for the set consisting of t...

Страница 2: ...fective area 23 23 mm E39 R12 Standard Effective area 7 7 mm E39 R13 Transparent detection Effective area 23 23 mm E39 R14 Sheet cuttable Effective area 195 22 mm E39 RS4 Sheet cuttable Effective area...

Страница 3: ...centage threshold incident light peak level no in cident light bottom level minimum incident light peak level maximum no incident light bottom level long bar display in cident level peak hold incident...

Страница 4: ...Changes the setting in reverse MODE key Depends on the MODE key setting Executes power tuning default set ting Executes a zero reset Switches the function to be set on the display Mode Main display r...

Страница 5: ...p to approximately 1 5 times the incident light level without power tuning Bottom Error The incident light level is too high for the power tuning target value The power can be decreased down to approx...

Страница 6: ...eaching for a Reflective Sensor Head is performed without a workpiece i e for the background A value about 6 greater than the incident light level is set as the threshold value This method is ideal to...

Страница 7: ...DOWN key for at least 3 seconds Threshold value RFCT Setting Errors RFCT OVER Flashes twice Teaching completed and previous display returns The threshold value that was set will flash twice Do one of...

Страница 8: ...he following and then repeat the operation Adjust the Head to decrease the incident light level Execute power tuning Do one of the following and then repeat the operation Adjust the Head to increase t...

Страница 9: ...ling edge are detected 250 s 500 s 500 s 1 ms 1 ms 2 ms 10 ms 20 ms 100 ms 200 ms Single edge This setting depends on the setting for the differential edge selection Switch to SET mode Double edge Sta...

Страница 10: ...ntage of the threshold value and the threshold value The incidient light peak level and no incident light bottom level The min incidient light peak level and max no incident light bottom level The dis...

Страница 11: ...and when the input turns OFF the average of these values is set as the threshold value Disabled if the detection function is set to DIFF differential operation A B A B Output for each channel 2OUT AR...

Страница 12: ...cified count value The count is decremented from the specified count value each time an ob ject is detected and the output is tur ned ON when the count reaches 0 A B Write results to EEPROM ON OFF Do...

Страница 13: ...pressing the MODE key The sub display will flash twice and key input will be disabled If a key is pressed while key operations are locked LOC will flash twice on the display to indicate that key oper...

Страница 14: ...n be joined 1 Mount the Amplifier Units one at a time onto the DIN Track 2 Slide the Amplifier Units together and press the Amplifier Units together until they click into place Secure the Units with a...

Страница 15: ...xternal input Blue E3C LDA21 and E3C LD7 NPN Models E3C LDA51 and E3C LD9 PNP Models Internal circuits Load 12 to 24 VDC Brown Black Orange Blue Output for chan Output for chan Output for chan Output...

Страница 16: ...nterest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into...

Отзывы: