background image

E3C-L

DA Series

A-455

E3C-LDA Series

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

E3C-LDA Series

• All seven laser types provide ample 

long distance, for the Diffuse Reflective 
Model 1.000 mm and for Retroreflec-
tive Models up to 7.000 mm.

• Coaxial Retroreflective Models provide 

detection performance equivalent to 
through-beam sensors, simplifying 
Sensor installation.

• Industry-first variable focal point and 

optical axis alignment mechanisms. 
Optimize for workpieces and improve 
inspection quality.

• Drive the laser with an Amplifier the 

same size as a Digital Fiber Amplifier.

Ordering Information

Sensor Heads

Note:

Select a reflector (sold separately) according to the application. 

Amplifier Units

Amplifier Units with Cables

Amplifier Units with Connectors

Sensing method

Focus

Model number

Remarks

Diffuse reflective

Spot

E3C-LD11

Mounting a Beam Unit (sold separately) allows the use of line and 

area beams.

Line

E3C-LD21

This model number is for the set consisting of the E39-P11 mount-

ed to the E3C-LD11.

Area

E3C-LD31

This model number is for the set consisting of the E39-P21 mount-

ed to the E3C-LD11.

Coaxial retroreflec-

tive

Spot (variable)

E3C-LR11 (See 

note.)

Mounting a Beam Unit (sold separately) allows the use of line and 

area beams.

Spot (2.0-mm fixed 

dia.)

E3C-LR12 (See 

note.)

---

Item

Appearance

Functions

Model

NPN output

PNP output

Advanced 

models

Twin-output 

models

Area output, self-diagno-

sis, differential operation

E3C-LDA11

E3C-LDA41

External-input 

models

Remote setting, counter, 

differential operation

E3C-LDA21

E3C-LDA51

Item

Appearance

Functions

Model

NPN output

PNP output

Advanced 

models

Twin-output 

models

Area output, self-diagno-

sis, differential operation

E3C-LDA6

E3C-LDA8

External-input 

models

Remote setting, counter, 

differential operation

E3C-LDA7

E3C-LDA9

Содержание E39-P31

Страница 1: ...od Focus Model number Remarks Diffuse reflective Spot E3C LD11 Mounting a Beam Unit sold separately allows the use of line and area beams Line E3C LD21 This model number is for the set consisting of t...

Страница 2: ...fective area 23 23 mm E39 R12 Standard Effective area 7 7 mm E39 R13 Transparent detection Effective area 23 23 mm E39 R14 Sheet cuttable Effective area 195 22 mm E39 RS4 Sheet cuttable Effective area...

Страница 3: ...centage threshold incident light peak level no in cident light bottom level minimum incident light peak level maximum no incident light bottom level long bar display in cident level peak hold incident...

Страница 4: ...Changes the setting in reverse MODE key Depends on the MODE key setting Executes power tuning default set ting Executes a zero reset Switches the function to be set on the display Mode Main display r...

Страница 5: ...p to approximately 1 5 times the incident light level without power tuning Bottom Error The incident light level is too high for the power tuning target value The power can be decreased down to approx...

Страница 6: ...eaching for a Reflective Sensor Head is performed without a workpiece i e for the background A value about 6 greater than the incident light level is set as the threshold value This method is ideal to...

Страница 7: ...DOWN key for at least 3 seconds Threshold value RFCT Setting Errors RFCT OVER Flashes twice Teaching completed and previous display returns The threshold value that was set will flash twice Do one of...

Страница 8: ...he following and then repeat the operation Adjust the Head to decrease the incident light level Execute power tuning Do one of the following and then repeat the operation Adjust the Head to increase t...

Страница 9: ...ling edge are detected 250 s 500 s 500 s 1 ms 1 ms 2 ms 10 ms 20 ms 100 ms 200 ms Single edge This setting depends on the setting for the differential edge selection Switch to SET mode Double edge Sta...

Страница 10: ...ntage of the threshold value and the threshold value The incidient light peak level and no incident light bottom level The min incidient light peak level and max no incident light bottom level The dis...

Страница 11: ...and when the input turns OFF the average of these values is set as the threshold value Disabled if the detection function is set to DIFF differential operation A B A B Output for each channel 2OUT AR...

Страница 12: ...cified count value The count is decremented from the specified count value each time an ob ject is detected and the output is tur ned ON when the count reaches 0 A B Write results to EEPROM ON OFF Do...

Страница 13: ...pressing the MODE key The sub display will flash twice and key input will be disabled If a key is pressed while key operations are locked LOC will flash twice on the display to indicate that key oper...

Страница 14: ...n be joined 1 Mount the Amplifier Units one at a time onto the DIN Track 2 Slide the Amplifier Units together and press the Amplifier Units together until they click into place Secure the Units with a...

Страница 15: ...xternal input Blue E3C LDA21 and E3C LD7 NPN Models E3C LDA51 and E3C LD9 PNP Models Internal circuits Load 12 to 24 VDC Brown Black Orange Blue Output for chan Output for chan Output for chan Output...

Страница 16: ...nterest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into...

Отзывы: