background image

D-186

Capacitive Sensors

Operation

Sensitivity adjustment

Remove the rear rubber cap of the E2K-C and turn the poten-

tiometer in the hole to adjust the sensitivity of the E2K-C.

The sensing distance increases by turning the potentiometer

clockwise and decreases by turning the potentiometer coun-

terclockwise. The potentiometer can make 15±3 valid turns

and then make slip turns because the potentiometer does not

have a stopper. The slip turns will not, however, damage the

potentiometer.

1. Slowly turn the potentiometer clockwise until the E2K-C

turns on with no sensing object.

2. Turn the potentiometer counterclockwise until the E2K-C

turns off with the sensing object located within the sensing

distance.

3. The E2K-C will be in stable operation if there is a difference

of 1.5 turns or more between the points the E2K-C is turned

on and off, otherwise the E2K-C will not be in stable oper-

ation.

4. Set the potentiometer midway between the two points.

5. If the distance of each sensing object varies, take step 2

with the sensing object located at the farthest sensing dis-

tance to be applied.

Remove this rubber 
cap and adjust the 
potentiometer.

Potentiometer

Stop turning the potentiometer 

at the moment the E2K-C turns off.

Potentiometer

Stop turning the potentiometer 

at the moment the E2K-C turns off.

The point the 

E2K-C turns on.

The point the 

E2K-C turns off.

Stable detection if the 

difference is 1.5 turns or more.

The point the 

E2K-C turns on.

The point the 

E2K-C turns off.

Midway

F502-EN2-04.book  Seite 186  Dienstag, 26. Juli 2005  5:48 17

Содержание E2K-C

Страница 1: ...er oil plastic etc without direct contact DC models acquire CE marking Ordering Information Sensors Accessories Order Separately Mounting Brackets Shape Sensing distance Model Output specifications Operating status NO NC DC 3 wire NPN DC 3 wire PNP E2K C25ME1 E2 KC25MF1 E2K C25ME2 E2K C25MF2 Shape Model Quantity Remarks Y92E A34 1 Supplied with the product 34 dia Unshielded 3 to 25mm ...

Страница 2: ...e length of 2 m Indicator lamp Detection indicator red LED Operating status with sensing object approaching E1 Y1 models NO E2 Y2 models NC Protective circuits Reverse connection protection surge absorber Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influence 15 max of sensing distan...

Страница 3: ...etweenblackandblue Operation indicator red Sensing object Main circuit Load Brown Brack 1 Output 2 Blue 4 4kW V 0V Tr 1 200 mA max load current 2 When a transistor is connected Yes No Operates Releases H L ON OFF Load betweenbrownandblack Output voltage betweenblackandblue Operation indicator red Sensing object Yes No Operates Releases H L ON OFF Load betweenbrownandblack Output voltage betweenbla...

Страница 4: ... off with the sensing object located within the sensing distance 3 The E2K C will be in stable operation if there is a difference of 1 5 turns or more between the points the E2K C is turned on and off otherwise the E2K C will not be in stable oper ation 4 Set the potentiometer midway between the two points 5 If the distance of each sensing object varies take step 2 with the sensing object located ...

Страница 5: ...ing Object Material The E2K C can detect almost any type of object The sensing distance of the E2K C how ever will vary with the electrical characteristics of the ob ject such as the conductance and inductance of the object and the water content and capacity of the object The max imum sensing distance of E2K C will be available if the ob ject is made of grounded metal Indirect Detection In the cas...

Страница 6: ...inyl insulated round cable cross sectional area of conductors 0 5 m u insulation diameter 1 9 mm Standard length 2 m 45 43 6 3 5 2 R2 6 Two elliptic holes for bracket mounting 35 2 23 5 15 Two M4 sensor clamping screws 42 30 35 6 E2K Proximity Sensor With Mounting Bracket Attached The holes are not drilled straight through Drill through the holes before using them Sensor mounting holes Two 5 5 dia...

Отзывы: