D-100
Inductive Sensors
Specifications
Brass type
Type
Ø
6,5
M8
Operating voltage
10 to 35 VDC
Rated supply voltage
24 VDC
Current consumption
max. 15 mA at 24 VDC
Sensing object
Ferrous metals
Mounting ((s)hielded, (n)on-shielded) *1
*1.
For detailed mounting instruction please refer to page D-105
s
n
s
n
Operating distance in mm
1,5
2,0
1,5
2,0
Tolerance of operating distance
±10%
Standard target size in mm (L x W x H in mm, FE 37)
6,5x6,5x1
8x8x1
Differential travel
1 % ... 15 % of operating distance
Max. response frequency in kHz
5,0
Control output
Type
E2EL-... E1 type: NPN-NO
E2 type: NPN-NC
F1 type: PNP-NO
F2 type: PNP-NC
Max-Load
200 mA
Max-on-state
Voltage drop
2,5 VDC (at 200mA load current and with 2 m cable)
Circuit protection
Reverse polarity, output short-circuit
Indicator
Operating indicator (yellow LED)
Ambient temperature
Operating: -25° to 70°C
Humidity
35 to 95 % RH
Influence of temperature
± 10 % max. of Sn at 23°C in temperature range of -25° to 70°C
Dielectric strength
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and
case
Electromagnetic compatibility EMC
EN 60947-5-2
Vibration resistance
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each
in X, Y and Z directions
Shock resistance
Destruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z
directions
Enclosure rating
IP 67 (EN 60947-1)
Connection *2
*2.
PUR cable and different length on request.
Pre-wired
2 m PVC-cable, 3 x 0,14 mm²
Connector
M8 plug
Weight in g
Pre-wired
long
45
50
short
43
48
Connector
long
10
15
short
8
13
Material
Case
Brass
Sensing face
PBTP