T Mode
Teaching Without Target Object
Step 1
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Set the operation
mode selector to T.
Press the TEACH
button once with no
target object
located.
If all the indicators
flash, press the
TEACH button
again.
Sensor Head
No target object
TEACH button
Sensor
Head side
Sensor
Head side
ON
Flashing
OK
No good
Step 2
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Set the operation
mode selector to
RUN.
Sensor Head
No target object
Operation mode selector
Sensor
Head side
OFF
Step 3
Status of target object
Control panel
Indicators
(Excess gain level indicators)
Move the target
object so that it
passes through the
sensing position
once.
Target
object
passing
Sensor Head
No switches are operated.
OFF after the
indicators are
ON for 1 s.
Sensor
Head side
OK
In
Operation
---
Sensitivity setting
position
---
---
p
ON
point
Target
object
Sensor Head
The ON point is set to a
distance that is approxi-
mately 1.2 times larger
than the distance between
the position where the
sample sensing object
passes and the sensing
surface of the Sensor
Head.
Note: After the E2CY is set to RUN mode, approximately 1.5 s will be required until the sensitivity is set from the moment the first target
object passes the sensing position. Therefore, move the next target object so that it passes through the sensing position 1.5 s after
the first target object passes the sensing position. Once the sensitivity adjustment is made, it will operate under the normal
response frequency.