manualshive.com logo in svg
background image

D-159

E2AU

E2A

U

Precautions

Safety Precautions

Power Supply

Do not impose an excessive voltage on the E2AU, otherwise it may
be damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.

Load Short-circuit

Do not short-circuit the load, or the E2AU may be damaged.

The E2AU’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.

Wiring

Be sure to wire the E2AU and load correctly, otherwise it may be
damaged.

Connection with No Load

Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2AU in operation, otherwise it may damage internal ele-
ments.

Do not expose the product to flammable or explo-
sive gases.

Do not disassemble, repair, or modify the product.

Correct Use

Designing

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.

Effects of Surrounding Metal

When mounting the E2AU within a metal panel, ensure that the
clearances given in the following table are maintained. 

(Unit: mm)

Note 1.

In the case of using the supplied nuts. 

If true flash mounting is necessary, apply a free zone of 
1.5 mm.

2.

In the case of using the supplied nuts. 

If true flush mounting is necessary, apply a free zone of 
4 mm.

Power OFF

The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power sup-
ply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.

Mutual Interference

When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.

(Unit: mm)

Type

Dimension

M12

M18

M30

Short 

barrel

Long 

barrel

Shielded

l

0


(See note 1.)


(See note 2.)

m

12

24

45

d

---

27

45

D

0

1.5

4

n

18

27

45

Non-
shielded

l

15

22

30

40

m

20

48

70

90

d

40

70

90

120

D

15

22

30

40

n

40

70

90

120

l

m

n

m

D

d dia.

l

Type

Dimension

M12

M18

M30

Short 

barrel

Long 

barrel

Shielded

A

30

60

110

B

20

35

70

Non-shiel-
ded

A

120

200

300

300

B

100

120

200

300

D10E-EN-01+E2AU+Datasheet.fm  Seite 159  Donnerstag, 12. Juni 2008  11:21 11

Содержание E2AU -

Страница 1: ...length Output configuration Operation mode NO M12 Shielded 4 0 mm Pre wired Brass 34 50 PNP E2AU M12KS04 WP B1 2M 56 72 PNP E2AU M12LS04 WP B1 2M M12 connector Brass 34 48 PNP E2AU M12KS04 M1 B1 56 7...

Страница 2: ...e g 02 2 mm 16 16 mm 8 Kind of connection WP pre wired PVC dia 4mm standard WS pre wired PVC dia 6mm WR pre wired PVC robotic cable dia 4mm WA pre wired PUR PVC PUR jacket dia 4mm WB pre wired PUR PV...

Страница 3: ...g object approaching B1 Protection circuit Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operati...

Страница 4: ...ect approaching B1 Protection circuit Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operating 40...

Страница 5: ...5 0 1 0 2 0 3 0 4 0 5 0 7 0 8 0 6 0 10 20 30 40 50 60 d t 1 mm X 0 4 8 12 16 20 10 20 30 40 50 60 70 80 d t 1 mm X Side length of sensing object d mm Brass Iron Sensing distance X mm Stainless steel S...

Страница 6: ...distance Sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 Load Brown Black See note 1 Blue V 0 V Note 1 With M8 connector models there is no output...

Страница 7: ...diameter 1 3 mm standard length 2 m 2 Operation indicator yellow Indicator See note 2 M12 1 17 72 3 56 7 4 M18 1 24 81 5 61 10 4 5 10 86 5 66 36 M30 1 5 See note 1 See note 1 See note 1 E2A M12LS04 WP...

Страница 8: ...yellow LED 4 90 Two clamping nuts Indicator See note Two clamping nuts Indicator See note Two clamping nuts Indicator See note 7 4 56 70 17 M12 1 M12 1 10 24 4 61 75 M18 1 M12 1 66 5 80 36 10 M30 1 5...

Страница 9: ...to the load Effects of Surrounding Metal When mounting the E2AU within a metal panel ensure that the clearances given in the following table are maintained Unit mm Note 1 In the case of using the supp...

Страница 10: ...ir the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and...

Отзывы: