D4JL/D4JL-SK40
28
<Slide Keys D4JL-SK40>
!
CAUTION
•
Do not drop the Switch. Doing so may prevent the Switch from
functioning to full capacity.
•
Mount the Switch securely to prevent it from falling. Otherwise,
injuries may occur.
•
Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction.
•
Make sure that the gap between the short bolt and guide is (±3
mm. Otherwise, excessive wear or damage may cause
malfunction.
•
To ensure safety, do not operate the Switch with anything other
than a Slide Key.
•
Be careful to avoid pinching your hand when operating the Switch.
•
Be sure to mount the Switch protective cover. Otherwise, your
hand may be injured by being pinched between the shot bolt and
Switch when closing the door with your hand on the Switch.
•
When opening the door, be sure to lower the disable-prevention
cover into position, attach a padlock, or take other steps to prevent
other people from operating the Switch.
•
The durability of the Switch is greatly influenced by the switching
conditions. Always test the Switch under actual working conditions
before application and use it in a switching circuit for which there
are no problems with performance.
•
The user must not maintain or repair equipment incorporating the
Switch. Contact the manufacturer of the equipment for any
maintenance or repairs required.
•
Do not shut the door while the shot bolt is extended. The Switch
may be damaged, preventing proper operation.
•
Do not apply excessive force in the direction of the slide. This may
damage the product and cause it to malfunction.
•
Insert the slide handle until the red operation indicator is
completely displayed in the operation display window.
•
Loose screws may result in malfunction. Use washers and tighten
the screws to the specified torques. Also, when mounting the
Switch to a door for disable-prevention purposes, purchase and
use tamper-resistant screws.
Tightening Torque
Technical Specifications
•
Do not store the Switch where corrosive gases (e.g., H
2
S, SO
2
,
NH
3
, HNO
3
, or CL
2
) or dust are present, or in locations subject to
high temperature or humidity.
•
Perform maintenance inspections periodically.
•
This product is for use only with OMRON Safety-door Switches.
Do not use it with door switches made by other manufacturers.
Incorrect operation may cause injury. Also, the product is
designed to be mounted so that it slides horizontally.
Do not mount the product in a vertically sliding configuration.
(excluding the D4NS-SK01)
Precautions for Safe Use
Precautions for Correct Use
Slide Key mounting screw (M6)
6.0 to 7.0 N·m
Switch mounting screw
(included with product)
3.2 to 3.
8
N·m
Switch protective cover mounting
screw (included with product)
1.2 to 1.4 N·m
Lever mounting screw
(included with product)
1.2 to 1.4 N·m
D4JL-SK40
Ambient operating temperature
−
10 to 55°C (with no icing)
Ambient operating humidity
95% max.
Mechanical durability
20,000 operations min.
Weight
Approx. 3.4 kg
(not including D4JL Guard Lock
Safety-door Switch)
Normal
Insufficient insertion
Operation display window