manualshive.com logo in svg
background image

 

Guard Lock Safety-door Switch

 D4JL

S

a

fe

ty D

o

o

r

Sw

it

c

h

e

s

P

recau

ti

on
s f
o

r

All Sa

fe

ty

 Do

o

r

Switch

e

s

D4
NS

D4
GS-

N

D

4

BS

D4
G

L

D4
JL

D

4

NL

D4
BL

D4
NH

D

4

0

B

D4
NS-

SK0

1

D4
NS-

SK3

0

D4
J

L

-SK3

0

67

G9SX-AD322-T15 (24 VDC) + D4JL-

@@@

A-

@@

 (Mechanical Lock Models)/Manual Reset

S3

OPEN

S6

41

42

11

12

S4

KM2

KM1

S7

OPEN

S10

41

42

11

12

S8

KM4

KM3

Motor controller 

(operation instruction)

S14

A2

S24 S34 S44 S54 L1 X1 X2

T11

A1

T12 T21 T22 T31 T32 T33

T41 T42

KM2

KM1

+24 V

Feedback loop

Stop signal 1

Guard

24 V

KM1 KM2

OFF

AND

PLCs, etc.

GND

G9SX-AD322-T15

Control circuits

Lock 
release 
signal 1

Lock 
release 
signal 1

S5

Open

(See 
note 2.)

Y1

Motor controller 

(operation instruction)

S14

A2

S24 S34 S44 S54 L1 X1 X2

T11

A1

T12 T21 T22 T31 T32 T33

T41 T42

KM4

KM3

+24 V

Feedback loop

Stop signal 2

Guard

+24 V

KM3 KM4

OFF

AND

PLCs, etc.

GND

G9SX-AD322-T15

Control circuits

S9

Open

(See 
note 2.)

Y1

S14

A2

S24

L1 L2

X1 X2

T11

A1

T12 T21 T22 T31 T32 T33 Y1

S2

12

11

21

22

+24 V

PLCs, etc.

S1

+24 V

S34

M1

KM2 

KM1

Motor controller

Open 

GND

G9SX-BC202

Control circuits

S34

M2

KM4

KM3

Motor controller

51

52

21

22

51

52

21

22

Logical AND 

connection

G9SX-BC 
Basic Unit

Emergency 
stop switch

Emergency stop switch

Safety Door 
Switch

Safety Door 
Switch

Advanced Unit
G9SX-AD

Advanced Unit
G9SX-AD

Machining section doors

Machining section doors

Tool changer door

Tool changer door 

No.

OFF-DELAY

0.5

0.4

0.3

0.2

15

10

7

5

4

3

2

1.5

1

0.6

0.7

0

S54

S44

S34

S24

S14

L1

A2

T42

T41

T22

T21

A1

X2

X1

Y1

T12

T11

T33

T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T15

No.

OFF-DELAY

0.5

0.4

0.3

0.2

15

10

7

5

4

3

2

1.5

1

0.6

0.7

0

S54

S44

S34

S24

S14

L1

A2

T42

T41

T22

T21

A1

X2

X1

Y1

T12

T11

T33

T31

T1

ERR

EI

AND

FB

ED

T2

PWR

T32

G9SX-AD322-T15

No.

T1

T2

FB

ERR

EI

PWR

L2

L1

S24

S14

A2

X2

T22

T21

A1

X1

T12

T11

Y1

T32 T33

T31

G9SX-BC202
24VDC

Application Example

Machining Center

• The entire machining center will stop when 

the emergency stop button is pressed.

• Power will not be supplied to the 

corresponding motor when a door is open.

S1: Emergency 

stop 

switch

S3 and S7: 

Guard Lock Safety-door Switches

S2, S5, and S9: 

Reset switches

S6 and S10: 

Lock release switches

S4 and S8: 

Safety-door Limit Switches with direct opening contacts

KM 1, KM 2, KM3, and KM4: Magnetic contactors
M1 and M2: 

3-phase motors

Содержание D4JL-1NFA-C5

Страница 1: ...page 55 for a list of models OMRON also offers Trapped Key Switches on mechanical lock models only The door can be opened only by supplying power to the solenoid and then turning the trapped key to un...

Страница 2: ...ical lock 24 VDC solenoid release G 24 VDC Solenoid lock Mechanical release 5 Indicator C 24 VDC green LED indicator D 24 VDC orange LED indicator 6 Release Key Type 5 Special release key See note 3 6...

Страница 3: ...D4JL 2NFG C5 1 2 14NPT D4JL 3NFG C5 M20 D4JL 4NFG C5 2NC 1NO 3NC PG13 5 D4JL 1PFG C5 G1 2 D4JL 2PFG C5 1 2 14NPT D4JL 3PFG C5 M20 D4JL 4PFG C5 3NC 2NC 1NO PG13 5 D4JL 1QFG C5 G1 2 D4JL 2QFG C5 1 2 14N...

Страница 4: ...FA C6 1 2 14NPT D4JL 3NFA C6 M20 D4JL 4NFA C6 2NC 1NO 3NC PG13 5 D4JL 1PFA C6 G1 2 D4JL 2PFA C6 1 2 14NPT D4JL 3PFA C6 M20 D4JL 4PFA C6 3NC 2NC 1NO PG13 5 D4JL 1QFA C6 G1 2 D4JL 2QFA C6 1 2 14NPT D4JL...

Страница 5: ...A C7 01 G1 2 D4JL 2PFA C7 01 1 2 14NPT D4JL 3PFA C7 01 M20 D4JL 4PFA C7 01 3NC 2NC 1NO PG13 5 D4JL 1QFA C7 01 G1 2 D4JL 2QFA C7 01 1 2 14NPT D4JL 3QFA C7 01 M20 D4JL 4QFA C7 01 3NC 3NC PG13 5 D4JL 1RF...

Страница 6: ...ils UL See note UL 508 CSA C22 2 No 14 CQC CCC GB14048 5 Application scheduled Item Utilization category AC 15 DC 13 Rated operating current Ie 3 A 0 27 A Rated operating voltage Ue 240 V 250 V Rated...

Страница 7: ...tacts door open closed detection and lock monitor Contact forms Operating pattern Remarks Lock monitor Door open closed detection D4JL NF 2NC 1NO 2NC 1NO NC contacts 11 12 and 21 22 have a certified d...

Страница 8: ...is supplied to the solenoid The door is unlocked manually E1 E2 Solenoid ON 41 12 NC 51 22 NC Door open closed detection and lock monitor contacts 31 32 NC Door open closed detection contact 33 34 NO...

Страница 9: ...ase button Terminal No and function Door open The door will lock when the door closes Door closed The door is locked Door open The door can be opened Door closed No power is supplied to the solenoid T...

Страница 10: ...he Key is not inserted The door will not lock when the door closes Door closed The Key is not inserted The door is not locked Door closed The Key is inserted The door is locked Door closed The Key is...

Страница 11: ...ples Mechanical Lock Models Solenoid Lock Models Operation Key removed Operation Key inserted Door locked Solenoid ON Door unlocked B B OFF Cross sectional view B B Cross sectional view B B B B OFF Cr...

Страница 12: ...Key inserted solenoid OFF and trapped key inserted Status Door locked and trapped key cannot be removed Cross sectional view B B OFF B B Cross sectional view B B OFF B B Cross sectional view B B OFF B...

Страница 13: ...L F D5 Operating characteristics Model D4JL F C5 D4JL F D5 Key insertion force Key extraction force 20 N max Approx 6 N Pre travel distance 14 mm max Movement before being locked 3 3 mm min Black Red...

Страница 14: ...6 21 B B Cross sectional view B B Cross sectional view A A Cap screw Conduit cap 2 conduits A A Four 5 4 dia holes Trapped key Manual release screw Head cap Six cover mounting screws 5 2 10 0 40 51 1...

Страница 15: ...tolerance of key hole 0 8 22 Black Red Black Red 22 51 7 5 Horizontal insertion radius R 270 Vertical insertion radius R 270 Center tolerance of key hole 0 8 Center tolerance of key hole 0 8 Operatio...

Страница 16: ...4 KM1 KM2 KM1 KM2 M 44 54 62 K2 K2 6 K3 1 a b OffDelay Timer Control Circuit K4 a b Operation instruction Feedback loop KM1 KM2 S3 Motor controller S1 Safety door Switch with direct opening contact S2...

Страница 17: ...34 M2 KM4 KM3 Motor controller 51 52 21 22 51 52 21 22 Logical AND connection G9SX BC Basic Unit Emergency stop switch Emergency stop switch Safety Door Switch Safety Door Switch Advanced Unit G9SX AD...

Страница 18: ...tioning to its full capability Make sure the Switch is mounted securely to prevent it from falling off Otherwise injury may result Mount the Operation Key so that it will not come into contact with pe...

Страница 19: ...it to the LOCK setting before resuming operation The release key is set in the unlock position at the factory for the D4JL A 5 and D4JL A 6 and in the lock position for the D4JL G 5 and D4JL A 7 If th...

Страница 20: ...er the machine stops operating Mounting Methods Tightening Torque Be sure to tighten each screw of the Switch properly Loose screws may result in malfunction Switch and Operation Key Mounting Mount th...

Страница 21: ...to a suitable torque The conduit cap is provided with the Switch Recommended Connectors Use a connector with a screw section not exceeding 9 mm Otherwise the screws will protrude into the case interi...

Страница 22: ...d Lock Safety door Switch will heat when power is supplied to the solenoid Do not touch these Switches Perform maintenance inspections periodically In the interest of product improvement specification...

Отзывы: