Precautions

Do not insert the Operation Key to the switch with the door open.
Machine may start operating and injury may be caused.

NOTICE

Do not use the D4GS-N

#

 Switch or D4GS-NK

#

 Operation Key (rub-

ber color: red) in combination with the D4GS-

#

 Switch or D4GS-K

#

Operation Key (rubber color: black).

Mount the Operation Key at a location where it will not come in con-
tact with users when the door is opened or closed.

When operating the D4GS-N as a part of a safety category circuit to
prevent injury, operate the NC contacts that have a direct opening
mechanism in direct opening mode. For safety purposes, tighten the
switch body and Operation Key with one-way screws or equivalents
or install a switch protection cover and warning label for safety pur-
poses to prevent easy removal of the D4GS-N.

Connect the fuse to the D4GS-N in series to prevent it from short-cir-
cuit damage. The value of the breaking current of the fuse must be
calculated by multiplying rated current by 150% to 200%. When
using the D4GS-N with EN ratings, use 10-A fuse Type gI or gG that
complies with IEC60269.

Do not supply electric power when wiring.

Do not use the D4GS-N where explosive gas, flammable gas, or any
other dangerous gas may be present.

Keep the electrical load below the rated value.

Never wire to a wrong terminal.

Be sure to evaluate the D4GS-N under actual working conditions
after installation.

Do not drop the D4GS-N. Excessive shock or vibration can cause
malfunction or damage to Switch characteristics. Do not disassem-
ble the internal switch, there are no user-serviceable parts inside.

Do not use the D4GS-N as a stopper. When mounting the D4GS-N,
be sure to locate a stopper as shown in the following illustration to
prevent the top of the Operation Key from hitting the switch head.

Cables should not be bent repeatedly. A cable is fixed with sealing
materials on the bottom of the D4GS-N. When excessive force may
be imposed on the cable, fix the cable with a fixing unit at the dis-
tance of 5 cm from the bottom of the D4GS-N as shown. When
bending the cable, secure the cable with more than 45-mm bending
radius so as not to cause damage to the insulator or sheath of the
cable. Do not fasten or loosen the conduit at the bottom of the
D4GS-N. When wiring, be sure not to allow a liquid such as water or
oil into the tip of cable.

Correct Use

Operating Environment

Do not use the D4GS-N in the following locations:

Locations subject to severe temperature changes

Locations subject to high temperatures or condensation

Locations subject to severe vibration

Locations subject to metal chips, oils, and chemicals inside a pro-
tective door

Life Expectancy

The life of the D4GS-N will vary with the switching conditions. Before
applying the D4GS-N, test the D4GS-N under actual operating con-
ditions and be sure to use the D4GS-N in actual operation within
switching times that will not lower the performance of the D4GS-N.

Mounting

Mounting hole dimensions for mounting the main body are as shown
below.

Tightening Torque

Be sure to tighten each screw of the D4GS-N properly, otherwise the
D4GS-N may malfunction.

Note: Mount securely, using screws of the specified size together with washers

(e.g., plain or spring washers).

Operation Key Mounting Holes

Stopper

5 cm

Fixing unit

Conduit

Bending radius 
more than 45 mm

Type

Torque

Size

Body mounting 
screw

0.75 to 1.15 N·m

M4 screw

Operation Key 
mounting screw

0.75 to 1.15 N·m

M4 screw

Two, M4

20

±

0.1 or 22

±

0.1

14

±

0.1

Two, M4

Two, M4

D4GS-NK1/NK2

D4GS-NK4

Содержание D4GS-N -

Страница 1: ...them is indicated with the mark Key Mounting Hole The key mounting hole is designed with rubber to absorb vibration and shock IP67 Degree of Protection Applicable to main body only Operation Key insertion face meets IP00 The D4GS N uses rust resistant materials and incorporates a drain opening as effective countermeasures against problems caused by water Note IP67 is based on the test method speci...

Страница 2: ...5 D4GS N3R 5 D4GS N4R 5 Vertical 1 m D4GS N1T D4GS N2T D4GS N3T D4GS N4T 3 m D4GS N1T 3 D4GS N2T 3 D4GS N3T 3 D4GS N4T 3 5 m D4GS N1T 5 D4GS N2T 5 D4GS N3T 5 D4GS N4T 5 Type Model D4GS NK1 D4GS NK2 D4GS NK4 1 1 2 3 Switch 1 Built in Switch 3 Cable Length 1 Operation Key Type D4GS NK Operation Key D4GS N 1 1NC 1NO slow action 2 2NC slow action 3 2NC 1NO slow action 4 3NC slow action 2 Direction of ...

Страница 3: ...69 as a short circuit protection device UL CSA UL508 CSA C22 2 No 14 C300 Q300 Agency Standard File No TÜV Rheinland EN60947 5 1 GS ET 15 UL see note UL508 CSA C22 2 No 14 E76675 Item AC 15 DC 13 Rated operating current Ie 0 75 A 0 27 A Rated operating voltage Ue 240 V 250 V Rated voltage Carry current Current A Voltage VA Make Break Make Break 120 VAC 2 5 A 15 1 5 1 800 180 240 VAC 7 5 0 75 Rated...

Страница 4: ...note 2 Mechanical 1 000 000 times min Electrical 100 000 times min 1 A resistive load at 125 VAC see note 3 Operating speed 0 1 to 0 5 m s Contact gap 2 x 2 mm min Operating frequency 30 operations minute Direct opening force see note 4 60 N min Direct opening travel see note 4 10 mm min Insulation resistance 100 MΩ min at 500 VDC between terminals of the same polarities between terminals of diffe...

Страница 5: ...ition Extraction completion position NC contacts 11 12 and 31 32 have an approved direct opening mechanism The terminals 11 12 and 31 32 can be used as unlike poles Stroke ON Operation Key insertion comple tion position Extraction completion position Only NC contacts 11 12 and 21 22 have an approved direct opening mechanism The terminals 11 12 21 22 and 33 34 can be used as unlike poles Stroke ON ...

Страница 6: ...ck D4GS N T Red Black Key insertion force 15 N max Key extraction force 30 N max Operating characteristics Model 22 mm min Direct opening force 60 N min Direct opening stroke 10 mm min 8 4 Operation Key center position 2 15 0 05R mounting hole Operation Key center position UL Style 2464 AWG22 Finishing O D 7 2 mm 2 15 0 05R mounting hole UL Style 2464 AWG22 Finishing O D 7 2 mm Movement before bei...

Страница 7: ...Black Red Black 27 1 See note Key insertion face Key insertion face 41 1 See note 41 1 See note 27 1 See note 13 5 to 16 Key insertion position Key insertion radius R 170 13 5 to 16 Key insertion position Key insertion face 13 5 to 16 Key insertion position Key insertion radius R 160 Note Mount with dimen sion of 26 4 for 160 R 240 Key insertion radius R 160 Key insertion face Note Mount with dime...

Страница 8: ... the tip of the operation key is positioned to the cen ter of the key insertion hole of the Switch Note 2 The operation key cannot be inserted or adjusted in a direction different from the one shown above Use the D4GS NK1 or D4GS NK2 if necessary 5 4 to 7 9 Key insertion position Key insertion radius R 160 21 1 See note Key insertion face 5 4 to 7 9 Key insertion positio 21 1 See note Key insertio...

Страница 9: ...4GS N be sure to locate a stopper as shown in the following illustration to prevent the top of the Operation Key from hitting the switch head Cables should not be bent repeatedly A cable is fixed with sealing materials on the bottom of the D4GS N When excessive force may be imposed on the cable fix the cable with a fixing unit at the dis tance of 5 cm from the bottom of the D4GS N as shown When be...

Страница 10: ...e white brown white or orange white means that the cover is blue brown or orange with a white line Terminal Numbers Identify terminal numbers based on the color of the insulation on the wire The safety and auxiliary contacts of D4GS N models of three termi nal contact construction and those of two terminal contact construc tion are described below The auxiliary contacts orange can be used as safet...

Отзывы: