F-34

Small Sealed Switch 

D4E-

@

N

Ratings

Note: 1.

The above current ratings are for a standard current and the values in parentheses are for models with a connector.

2.

Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3.

Lamp load has an inrush current of 10 times the steady-state current.

4.

Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Note: 1.

The above values are initial values.

2.

The above ratings may vary depending on the model. Contact your OMRON representative for further details.

3.

Durability values are calculated at an operating temperature of 5

°

C to 35

°

C, and an operating humidity of 40% to 70%. Contact your

OMRON sales representative for more detailed information on other operating environments.

Rated voltage

General-purpose

Micro load

Non-inductive load

Inductive load

Non-inductive load

Resistive load

Lamp load

Inductive load

Motor load

Resistive load

NC

NO

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC

5 (1) A

1.5 (1) A

3 (1) A

2 (1) A

1 (1) A

0.1 A

250 VAC

5 (1) A

1.5 (1) A

3 (1) A

1 A

0.5 A

---

8 VDC

5 (1) A

---

1.5 (1) A

---

0.1 A

14 VDC

5 (1) A

---

1.5 (1) A

---

0.1 A

30 VDC

5 (1) A

---

1.5 (1) A

---

0.1 A

125 VDC

0.5 A

---

0.05 A

---

---

250 VDC

0.25 A

---

0.03 A

---

---

Inrush current

NC

10 A max.

NO

10 A max.

Degree of protection

IP67

Durability (see note 3)

Mechanical: 10,000,000 operations min.
Electrical:

500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)

Operating speed

0.1 mm to 0.5 m/sec

Operating frequency

Mechanical: 120 operations/min
Electrical:

30 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M

 min. (at 500 VDC)

Contact resistance

15 m

 max. (initial value)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal parts 
and ground, and between each terminal and non-current-carrying metal part

Rated insulation voltage (Ui)

250 VAC

Switching overvoltage

1,000 VAC max. (EN60947-5-1)

Pollution degree 
(operating environment)

3 (EN60947-5-1)

Short-circuit protective device (SCPD)

10 A fuse (type gG or gI, IEC269 approved)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional enclosed thermal current 
(I

the

)

5 A (EN60947-5-1)

Protection against electric shock

Class II (grounding not required with double insulation)

Vibration resistance

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Destruction: 1,000 m/s

2

 min.

Malfunction: 300 m/s

2

 min.

Ambient temperature

Operating: –10

°

C to 80

°

C (with no icing)

Ambient humidity

Operating: 95% max.

Weight

Approx. 86 g (in case of roller plunger)

Содержание D4E-1A20N

Страница 1: ...acteristics between D4E N and D4E models Model Number Structure Model Number Legend 1 Rated Current 1 5 A at 125 VAC 1 A at 125 VAC 30 VDC for model with a connector 2 0 1 A at 125 VAC 0 1 A at 125 VAC 30 VDC for model with a connector 2 Actuator A Roller plunger B Crossroller plunger C Plunger D Sealed roller plunger E Sealed crossroller plunger F Sealed plunger G Roller lever H One way action ro...

Страница 2: ...oad with cable D4E 1A 0N D4E 2A 0N D4E 1A20N see note 2 D4E 2A20N D4E 1A21N D4E 2A21N D4E 1B 0N D4E 2B 0N D4E 1B20N see note 2 D4E 2B20N D4E 1B21N D4E 2B21N D4E 1C 0N D4E 2C 0N D4E 1C20N see note 2 D4E 2C20N D4E 1C21N D4E 2C21N D4E 1D 0N D4E 2D 0N D4E 1D20N see note 2 D4E 2D20N D4E 1D21N D4E 2D21N D4E 1E 0N D4E 2E 0N D4E 1E20N see note 2 D4E 2E20N D4E 1E21N D4E 2E21N D4E 1F 0N D4E 2F 0N D4E 1F20N ...

Страница 3: ... 10 A 60 A 6 A 7 200 VA 720 VA 240 V 30 A 3 A Model Applicable category and ratings Thermal current Ithe Indicator I II III IV 1 00 AC 14 0 5 A 125 VAC 5 A 1 10 DC 12 0 5 A 30 VDC 5 A 1 20 21 22 AC 15 2A 250 VAC DC 12 2A 48 VDC 5 A 1 23 24 L AC 15 2A 250 VAC 5 A Neon lamp 1 23 24 L1 DC 12 2A 12 VDC 5 A LED 1 23 24 L2 DC 12 2A 24 VDC 5 A LED 1 23 24 L3 DC 12 2A 48 VDC 5 A LED 2 00 AC 14 0 1A 125 VA...

Страница 4: ...10 A max NO 10 A max Degree of protection IP67 Durability see note 3 Mechanical 10 000 000 operations min Electrical 500 000 operations min 5 A at 250 VAC resistive load 5 000 000 operations min 10 mA at 24 VDC resistive load Operating speed 0 1 mm to 0 5 m sec Operating frequency Mechanical 120 operations min Electrical 30 operations min Rated frequency 50 60 Hz Insulation resistance 100 MΩ min a...

Страница 5: ... 0 1 mm 0 1 mm 0 1 mm 0 1 mm 0 1 mm OP 31 4 0 8 mm 31 4 0 8 mm 25 4 0 8 mm 41 3 0 8 mm 41 3 0 8 mm Model D4E 1F N D4E 2F N D4E 1G N D4E 2G N D4E 1H N D4E 2H N OF max 11 77 N 3 92 N 3 92 N RF min 4 90 N 0 78 N 0 78 N PT max 1 5 mm 2 mm 2 mm OT min 3 mm 4 mm 4 mm MD reference value 0 1 mm 0 3 mm 0 3 mm OP 30 0 8 mm 23 1 0 8 mm 34 3 0 8 mm AC DC COM NO NC COM NC NO COM NO NC 2 3 4 1 COM 2 3 4 1 NO NC...

Страница 6: ...D4E has a space of 7 5 mm horizontally Screw terminal incorporates a M3 screw with a toothed washer The actuator strength has been increased to 4 903 N D4E 294 N in order to prevent faulty resetting of the bearing which may occur when the roller is pressed with excessive force Switch cover ensures high insulation between the terminals and die cast Double insulation means that grounding is unnecess...

Страница 7: ... 10 46 6 5 0 5 57 4 2 0 2 0 4 7 holes 16 dia 4 7 holes Roller Plunger 4 7 holes 16 dia 4 7 hole Roller Plunger Cross Roller Plunger Cross Roller Plunger D4E 1A00N D4E 1A10N D4E 2A00N D4E 2A10N D4E 1A20N See note 4 D4E 2A20N See note 4 D4E 1A21N See note 3 D4E 2A21N See note 3 0 4 2 0 2 dia holes Two panel mounting nut 2 5 mm thickness 17 mm width across flats 11 dia x 4 7 stainless sintered alloy ...

Страница 8: ...ger Sealed Roller Plunger Sealed Roller Plunger D4E 1C00N D4E 1C10N D4E 2C00N D4E 2C10N D4E 1C20N See note 4 D4E 2C20N See note 4 D4E 1C21N See note 3 D4E 2C21N See note 3 D4E 1D00N D4E 1D10N D4E 2D00N D4E 2D10N D4E 1D20N See note 4 D4E 2D20N See note 4 D4E 1D21N See note 3 D4E 2D21N See note 3 0 4 2 0 2 dia holes Two panel mounting nut 2 5 mm thickness 17 mm width across flats 7 8 dia stainless s...

Страница 9: ...holes Sealed rubber Sealed Cross Roller Plunger Sealed Cross Roller Plunger Sealed Plunger Sealed Plunger D4E 1E00N D4E 1E10N D4E 2E00N D4E 2E10N D4E 1E20N See note 4 D4E 2E20N See note 4 D4E 1E21N See note 3 D4E 2E21N See note 3 D4E 1F00N D4E 1F10N D4E 2F00N D4E 2F10N D4E 1F20N See note 4 D4E 2F20N See note 4 D4E 1F21N See note 3 D4E 2F21N See note 3 0 4 2 0 2 dia holes 11 dia x 4 7 stainless sin...

Страница 10: ...ne way Action Roller Lever One way Action Roller Lever Operating direction Operating direction D4E 1G00N D4E 1G10N D4E 2G00N D4E 2G10N D4E 1G20N See note 4 D4E 2G20N See note 4 D4E 1G21N See note 3 D4E 2G21N See note 3 D4E 1H00N D4E 1H10N D4E 2H00N D4E 2H10N D4E 1H20N See note 4 D4E 2H20N See note 4 D4E 1H21N See note 3 D4E 2H21N See note 3 0 4 2 0 2 dia holes 9 5 dia x 4 8 stainless sintered allo...

Страница 11: ... when the Switch is not operating Because of the molded terminal model any change to the Switch wiring cannot be made AC Operation A neon lamp indicator is provided The operating voltage is 90 to 250 VAC There is no difference in operating characteristics between D4E AC Models and corresponding D4E Standard Models There is no difference in dimensions between D4E AC Models and D4E Standard Models E...

Страница 12: ... the table below Internal Circuit Note An external 24VDC power supply can be used eg OMRON S8VS Example When ordering a D4E DC Model add the following suffix to the model number Basic Model The model number of the D4E 1A23N with a built in 12 V LED indicator is D4E 1A23L1N Type Voltage rating Lamp current Internal resistance L1 12 V Approx 2 4 mA 4 3 kΩ L2 24 V Approx 1 2 mA 18 kΩ L3 48 V Approx 2...

Страница 13: ...crews and washers The tightening torque applied to each terminal must be 1 18 to 1 37 N m Tighten the screws to the specified torque An excessive tightening torque may damage the Switch and cause a malfunction Mounting Holes When mounting the panel mount type Switch with screws on a side surface remove the hexagonal nuts from the actuator When mounting the panel mount type on a panel tighten the h...

Страница 14: ...wn below No Type Torque 1 Terminal screw M3 0 24 to 0 44 N m 2 Switch mounting screw M4 1 18 to 1 37 N m 2 1 In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No C028 E1 05 ...

Отзывы: