background image

Manual P/N 99983-0020 022016 Rev.C

©2016 Omron Scientific Tetchnologies, Inc. All rights reserved.

EU Declaration of Conformity

The manufacturer named below herewith declares that the product 

fulfills the provisions of the directive(s) listed below and that the 

related standards have been applied.

OMRON Scientific Technologies Inc.

6550 Dumbarton Circle

Fremont, CA 94555, U.S.A.

Directives applied:

Machinery directive 2006/42/EC

EMC directive 2004/108/EC (valid until 19th April 2016)

EMC directive 2014/30/EU (valid from 19th April 2016)

RoHS Directive 2011/65/EC

Standards applied:

EN 60947-5-3:2013

EN 60947-5-1:2004+AC:2005+A1:2009

EN 60947-1:2007+A1:2011

EN ISO 13849-1:2008:+AC:2009

EN 62061:2005+AC:2010+A1:2013

EN ISO 14119:2013

Fremont, Date: August 12, 2015

Marty Krikorian

Director, Quality Control

Standards:  ISO14119  EN60947-5-3  EN60204-1

ISO13849-1  UL508

:

a

t

a

D

 

y

ti

li

b

a

il

e

R

 

d

n

a

 

n

o

it

a

c

if

i

s

s

a

l

C

 

y

t

e

f

a

Dielectric Withstand:  250VAC

Insulation Resistance:  100 Mohms

Switching Distance:  S

ao

 1mm Close

S

ar

  10mm Open

Switching Frequency:  1.0 Hz maximum

Approach Speed:  200mm/m   to   1000mm/s

Body Material:  D40ML-P__   = Plastic

D40ML-M__  = Die-Cast Metal

D40ML-SS__= 316 Stainless Steel

Temperature Range:  -25C to +40C

Vibration:   10Hz to 55Hz, 1mm amplitude.

Shock:   11ms 30g

Enclosure Protection:  IP67 (Plastic or Metal)

IP69K (Stainless Steel) with flying leads

Cable Type:  PVC   8 core   6mm OD

Mounting Bolts:  2 x M5  Tightening torque 1.0 Nm

Mounting Position:  Any

Power Supply:  +24VDC  ± 10% (selv / pelv)

Holding Force:  SS2: F1max (typical): 600N Fzh: 450N

SS1: F1max (typical): 950N Fzh: 700N

P2 & M2 Version: F1max (typical

)

: 900N Fzh: 675N

P1 & M1 Version: F1max (typical

)

: 1500N Fzh: 1150N

Max. Switched Current (Outputs):  200mA (min. internal resistance 8.5 Ohms)

Characteristic Data according to EN ISO13849-1:

Performance Level  e  If both channels are used in combination 

with a SIL3/PLe control device

Category  Cat. 4 

MTTFd  1100a 

Diagnostic Coverage DC  99% (high)

Number of operating days per year:  dop = 365d

Number of operating hours per day:  hop = 24h

B10d:  Not mechanical parts implemented

When the product use deviates from these assumptions (different load, operating 

frequency, etc.) the values must be adjusted accordingly.

Information with regard to UL508

Use LVLC or Class 2 supply. Type 1 enclosure.

WARNING: Hot surface – risk of burn if used at ambient temperature of +40C degrees.

             

Affix a warning label to the switch.

D40ML Series

Operating Instructions for D40ML Series

Quick Connect (QC)  

250mm  (10”) 

M12  8 -Way 

Male Plug

Conductor

Colors  

Function

Power  

Ratings  

Blue  

0VDC  

50mA max. (sensing)

 

Red 

24VDC 

Orange  

Lock Applied (+24VDC)   500mA max. (locked)

 

Black  

Safety Output 1

200mA max.

White 

Safety Output 1

Yellow  

Safety Output 2

200mA max.

Green  

Safety Output 2

Brown  

Auxiliary Signal

+24 VDC 200mA

 

Connection Colors

LED Operation and Switch Status Indication:

The D40ML switch uses 2 LED to indicate all the different possible 

switch states. The LED are in a clearly visible location at either side of 

the cable exit point.

Switch Status 

Guard 

Green LED 

Yellow LED 

Locked 

Closed 

Steady 

Off 

Solenoid Power OFF (unlocked)

 

Closed 

Flashing 

Off 

Guard Open 

Open 

Off 

Steady 

Door Forced Open 

Open 

Off 

Flashing 

Actuator Operating 