manualshive.com logo in svg
background image

CSM_CK3W-MD71_0_DS_E_DITA_1_1

1

Digital I/O Unit

CK3W-MD71

@

0

Digital I/O units 
for CK3M Controller

Features

• Built-in 16 DC inputs and 16 transistor outputs
• Two different models: PNP and NPN

CK3W-MD71

@

0

EtherCAT

®

 is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
The product photographs and figures that are used in this catalog may vary somewhat from the actual products.

Содержание CK3W-MD71 0 Series

Страница 1: ...odels PNP and NPN CK3W MD71 0 EtherCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany Other company names and product names in this document are the tra...

Страница 2: ...pply Unit Unless the Expansion Master Unit CK3W EXM01 is connected adjacent to the right side of the CPU Unit the Sys Status register CK3WConfigErr becomes 5 Letter Configuration Remarks A Power Suppl...

Страница 3: ...D Unit Analog Input Unit You can add 4 or 8 voltage inputs G End Cover Must be connected to the right end of the CPU Rack and Expansion Rack The CPU Unit and the Expansion Slave Unit are each provided...

Страница 4: ...o 95 with no condensation or icing Atmosphere Must be free of corrosive gases Ambient Storage Temperature 25 to 70 C with no condensation or icing Vibration Resistance Conforms to IEC 60068 2 6 5 to 8...

Страница 5: ...min OFF voltage OFF current 5 VDC max 1 mA max ON OFF response time 20 s max 400 s max Isolation method Isolation by Photocoupler between input and internal circuit Circuit configuration NPN type PNP...

Страница 6: ...4 VDC Maximum load current 0 5 A point 2 A Unit Maximum inrush current 4 0 A point 10 ms max Leakage current 0 1 mA max Residual voltage 1 0 V max ON OFF response time 0 1 ms max 0 8 ms max Isolation...

Страница 7: ...esidual voltage 1 0 V max ON OFF response time 0 1 ms max 0 8 ms max Isolation method Isolation by Photocoupler between output and internal circuit Load short circuit prevention Provided Circuit confi...

Страница 8: ...dicator Shows the power supply status C Digital input output status indicator Shows the digital input output status D Terminal block Connects the digital input output E Unit connector Connector that c...

Страница 9: ...ires and crimping tools are listed in the following table Using Twisted or Solid Wires Required Tools Use a flat blade screwdriver to remove wires The recommended screwdriver is as follows Dimensions...

Страница 10: ...ogrammable Multi Axis Controller The following information is provided on the CK3M series Pro grammable Multi Axis Controller Details of commands Details of data structure Power PMAC IDE User Manual O...

Страница 11: ...ERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remot...

Отзывы: