Input Signal Types
Section 3-3
35
3-3-3
Pulse & Direction
In this configuration, count pulses are applied to input A. The direction of counting
is controlled by the level of the signal applied to input B. If input B is high, the
Counter increments on the rising edges of input A. If input B is low, the Counter
decrements on the rising edges of input A.
Note
For Counter Reset options refer to section Section 3-6
Input A
Input Z
Input B
Counter
Increment encoder
or other pulse
generator
Sensor or
switch
Count pulse
Direction
control
Count pulse
Direction control:
High = Increment
Low = Decrement
1
2
3
2
1
2
3