Omron CJ1M-CPU12 Скачать руководство пользователя страница 7

 11

CJ1M CPU Units

CJ1M-CPU12/13
CJ1M-CPU22/23

Cu

CPU Units

Dimensions

Model

Number of 

I/O points

Maximum 

number of 

Expansion 

Racks

Maximum 

number of 

connectable 

Units

Program 

capacity

Data memory 

capacity

LD 

instruction 

processing 

speed

Built-in 

ports

Mountable 

options

Built-in I/O

CJ1M-CPU12

320

None

10 Units

10 Ksteps

32 Kwords 
(DM only, no 
EM)

100 ns

Peripheral 
port and RS-
232C port

Memory 
Card (com-
pact flash)

None

CJ1M-CPU13

640

1 Unit

CPU Rack: 
10 Units
Expansion 
Rack: 10 Units

20 Ksteps

CJ1M-CPU22

320

None

10 Units

10 Ksteps

10 inputs and 6 outputs
Inputs: 4 interrupt inputs 
(pulse catch); 2 high-
speed counter inputs
(Phase differential: 
50 kHz; Single phase: 
100 kHz)
Outputs: 2 pulse outputs 
(2 points for positioning, 
100-kHz speed control, 
and PWM output)

CJ1M-CPU23

640

1 Unit

CPU Rack: 
10 Units
Expansion 
Rack: 10 Units

20 Ksteps

CJ1M-CPU12/13

CJ1M-CPU22/23

65

73.9

90

2.7

2.7

31

90

2.7

2.7

65

49

83.6

83.7

CJ1W-CIF11

Weight: 120 g

Weight: 170 g

CPU Unit

14.7

End Plate

(Provided with 
the CPU Unit.)

RS-422A  
Converter

34

38.8

Weight: 20 g

Rack Dimensions

35.4

27

27.6

65

90

W

Содержание CJ1M-CPU12

Страница 1: ...1 02 Printed in Japan 1002 3M Note Do not use this document to operate the Unit OMRON Corporation FA Systems Division H Q 66 Matsumoto Mishima city Shizuoka 411 8511 Japan Tel 81 55 977 9181 Fax 81 55...

Страница 2: ......

Страница 3: ......

Страница 4: ...A computer is not required at the production site enabling downsizing and cost reductions...

Страница 5: ......

Страница 6: ...W KS001 E See below CX Programmer Ver 3 0 WS02 CXPC1 EV3 XW2Z 200S CV for IBM PC AT or compatible XW2Z 500S CV for IBM PC AT or compatible 5 m CX Simulator Ver 1 3 WS02 SIMC1 E Serial Communications U...

Страница 7: ...Unit CPU Rack 10 Units Expansion Rack 10 Units 20 Ksteps CJ1M CPU22 320 None 10 Units 10 Ksteps 10 inputs and 6 outputs Inputs 4 interrupt inputs pulse catch 2 high speed counter inputs Phase differe...

Страница 8: ...Bus S Master Units I O Units with 31 mm width Basic I O Units other than the above Special I O Units CPU Bus Units Model Current consumption at 5 V Current consumption at 24 V CJ1M CPU12 CPU13 0 58 A...

Страница 9: ...0000 to CIO 0999 I O bits are allocated to Basic I O Units These bits can be used as work bits when not used for the applications de scribed on the left Built in I O Area 10 input bits CIO 296000 to C...

Страница 10: ...the PLC is turned OFF or the operating mode is changed Index Registers IR0 to IR15 Store PLC memory addresses for indirect addressing Task Flag Area 32 TK0000 to TK0031 Task Flags are read only flags...

Страница 11: ...ks Clock Provided on all models Accuracy 1 5 min mo at 25 C Note 1 The accuracy varies with the temperature 2 Used to store time when power is turned ON and when errors occur Power OFF detection time...

Страница 12: ...purpose output 4 General purpose output 5 Pulse output CW CCW Pulse output 0 CW Pulse output 0 CCW Pulse output 1 CW Pulse output 1 CCW Pulse direc tion Pulse output 0 pulse Pulse output 1 pulse Pulse...

Страница 13: ...d counter 0 A531 bit 01 high speed counter 1 Item Specification Output frequency 1 Hz to 100 kHz 1 to 100 Hz 1 Hz units 100 Hz to 4 kHz 10 Hz units 4 to 100 kHz 100 Hz units Frequency acceleration dec...

Страница 14: ...nts IN0 to IN5 IN6 to IN9 IN0 to IN5 IN6 to IN9 Input voltage 20 4 to 26 4 VDC Conforms to RS 422 line driver equivalent to AM26LS31 The power supply voltage on the connected side must be 5 V 5 Input...

Страница 15: ...r point for 10 ms max Leakage current 0 1 mA max Residual voltage 0 6 V max ON response time 0 1 ms max OFF response time 0 1 ms max Fuse None External power supply 10 2 to 26 4 VDC 50 mA min Circuit...

Отзывы: