31
Memory Allocation
Section 4-1
4-1-3
DM Allocation Chart
Dedicated DM (Read Only)
General DM (Read and Write)
DM m
DM (m+1)
DM (m+2)
DM (m+3)
DM (m+4)
DM (m+5)
DM (m+6)
DM (m+7)
DM (m+8)
DM (m+9)
DM (m+10)
(m = 1000 + 100 x Unit no.)
DM number
Data item
Leading DM number for cam data storage
Number of cam data storage combinations (1 to 8)
Transfer of data permitted/not permitted for number
of revolutions required for a single process
Bank 1
Bank 2
Bank 3
Bank 4
Bank 5
Bank 6
Bank 7
Bank 8
Setting data for number
of revolutions required
for a single process
The DM 1000 data block is for reading
only. Therefore data cannot be written
by means of the program. Set the data
with a peripheral device such as the
the Programming Console.
DM x
DM (x+1)
DM (x+2)
DM (x+3)
DM (x+4)
DM (x+5)
DM (x+6)
DM (x+7)
DM (x+8)
DM (x+9)
DM (x+10)
DM (x+11)
DM (x+12)
DM (x+13)
DM (x+14)
(x=0000 to 0999
−
15 x number of cam data storage combinations)
Bank no.
Cam no.
Step no. 1
Step no. 1
Step no. 2
Step no. 2
Step no. 3
Step no. 3
Step no. 4
Step no. 4
Step no. 5
Step no. 5
Step no. 6
Step no. 6
Step no. 7
Step no. 7
ON data
OFF data
ON data
ON data
ON data
ON data
ON data
ON data
OFF data
OFF data
OFF data
OFF data
OFF data
OFF data
DM number
Data item
The 15 words shown on the left
constitute a single block. Bank
numbers and cam numbers can
be changed, and data can be set
or retrieved for a total of eight
blocks from DM (x + 15) onwards.
Содержание C200H-CP114
Страница 1: ...23 5 7 21 0 18 Cat No W224 E1 2 SYSMAC C200H CP114 Cam Positioner Unit...
Страница 2: ......
Страница 3: ...C200H CP114 Cam Positioner Unit Operation Manual Revised January 2001...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 59: ...45 SECTION 5 Troubleshooting This section provides possible errors and corrections Error Detection 46...
Страница 70: ......