background image

FRANÇAIS

ENGLISH

INSTRUCTION MANUAL

®

5 series 

Blood Pressure Monitor

Model BP742CANN

Содержание BP742CANN

Страница 1: ...FRAN AIS ENGLISH INSTRUCTION MANUAL 5 series Blood Pressure Monitor Model BP742CANN...

Страница 2: ...d Time 14 3 USING THE DEVICE 15 3 1 Applying the Arm Cuff 15 3 2 How to Sit Correctly 17 3 3 Taking a Measurement 18 3 4 Using the Memory Function 22 Care and Maintenance 4 ERROR MESSAGES AND TROUBLES...

Страница 3: ...ic monitor does not need a stethoscope so the monitor is simple to use Intended Use This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient popula...

Страница 4: ...reading Do not use the device on the injured arm or the arm under medical treatment Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion Consult your physician...

Страница 5: ...Do not use this device on infants or persons who cannot express their intentions Do not use the device for any purpose other than measuring blood pressure Use only the approved arm cuff for this devic...

Страница 6: ...e only an OMRON AC adapter designed for this device Use of unsupported adapters may damage and or may be hazardous to the device Battery Usage Do not insert the batteries with their polarities incorre...

Страница 7: ...tion with the monitor not the tube itself Do not drop the monitor or subject device to strong shocks or vibrations Do not inflate the arm cuff when it is not wrapped around your arm Do not use the dev...

Страница 8: ...itor Arm cuff A Display B Up Down buttons C USER ID selection switch D Date Time setting button E START STOP button F Memory button G Battery compartment H Air jack I AC adapter jack for optional AC a...

Страница 9: ...ssure P Low battery symbol Q Heartbeat symbol Flashes during measurement R Memory symbol S Average value symbol T Date Time display U Movement error symbol V Irregular heartbeat symbol W Blood pressur...

Страница 10: ...irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow the directions of your physician Movement Error Symbol The movement error symbol is di...

Страница 11: ...delines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels These are from statistical values for blood pressure Office Home Systolic Blood...

Страница 12: ...ments should be taken in a quiet place 4 Remove tight fitting clothing from your arm 5 Sit on a chair with your feet flat on the floor Rest your arm on a table so that the arm cuff is at the same leve...

Страница 13: ...display turn the monitor off then replace all batteries at the same time Long life alkaline batteries are recommended The measurement values continue to be stored in memory even after the batteries ar...

Страница 14: ...and then the month flashes Repeat the same steps to change the month day hour and minute 3 Press the START STOP button to turn the monitor off Notes If the batteries have been replaced the date and t...

Страница 15: ...rm Do not place the arm cuff over thick clothes 1 Insert the air plug into the air jack securely 2 Wrap the arm cuff firmly in place around your left upper arm The bottom edge of the arm cuff should b...

Страница 16: ...w Be careful not to rest your arm on the air tube The blood pressure can differ between the right arm and the left arm and the measured blood pressure values can be different OMRON recommends to alway...

Страница 17: ...e room temperature Avoid bathing drinking alcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your feet flat on the floor Sit upright with your...

Страница 18: ...nt press the START STOP button once to deflate the arm cuff Remain still and quiet while taking a measurement The monitor is designed to take measurements and store the measurement values in the memor...

Страница 19: ...olic pressure is more than 210 mmHg After the arm cuff starts to inflate press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure Notes...

Страница 20: ...nitor off The monitor automatically stores the measurement result in its memory It will automatically turn off after 2 minutes Note Wait 2 3 minutes before taking another measurement Waiting between m...

Страница 21: ...r 2 Release the START STOP button when the Date Time display turns off The arm cuff will start to inflate automatically DO NOT adjust medication based on measurement results from this blood pressure m...

Страница 22: ...en within 10 minutes Notes If there are only 2 measurement values in the memory for that period the average will be based on these 2 values If there is 1 measurement value in the memory for that perio...

Страница 23: ...r User ID 1 or 2 2 Press the button The Memory number appears for a second before the pulse rate is displayed The newest set is numbered 1 3 Press the or button to view the values stored in memory To...

Страница 24: ...1 or 2 2 Press and hold the button for more than 3 seconds Notes If the previous measurement was taken without setting the date and time the average value is not calculated If there are no measuremen...

Страница 25: ...deleted by USER ID 1 Select your User ID 1 or 2 2 Press the button while the memory symbol appears 3 While holding the button down press the START STOP button for more than 3 seconds Note You cannot...

Страница 26: ...surement Repeat the steps in section 3 3 If this error continues to appear contact your physician Movement during measurement Carefully read and repeat the steps in section 3 3 The batteries are low Y...

Страница 27: ...ff has not been inflated sufficiently Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 If E2 appears repeatedly inflate the arm cuff manually until it is 30 to 4...

Страница 28: ...Movement during measurement Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 Clothing is interfering with the arm cuff Remove any clothing interfering with the...

Страница 29: ...batteries with new ones Check the battery installation for proper placement of the battery polarities Refer to section 2 1 Measurement values appear too high or too low Blood pressure varies constant...

Страница 30: ...ot wash the device and any components or immerse them in water Do not use gasoline thinners or similar solvents to clean the device Use a soft and dry cloth or a soft and moistened cloth and neutral s...

Страница 31: ...he arm cuff Note Do not bend or crease the air tube excessively Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct sunli...

Страница 32: ...2 5 MAINTENANCE AND STORAGE 5 3 Optional Medical Accessories Arm cuff Arm circumference 7 9 17 22 cm Arm circumference 9 17 22 42 cm CD CS9 Model HEM CS24 CD WR17 Model HEM RML31 AC Adapter HEM ADPTW5...

Страница 33: ...rt the AC adapter plug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical o...

Страница 34: ...Operating temperature humidity 50 F to 104 F 10 C to 40 C 15 to 90 RH Storage temperature humidity air pressure 4 F to 140 F 20 C to 60 C 10 to 95 RH 700 to 1060 hPa Weight Monitor Approximately 10 5...

Страница 35: ...specifications are subject to change without notice In the clinical validation study the 5th phase was used on 85 subjects for determination of diastolic blood pressure This device has not been valida...

Страница 36: ...stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 37: ...arranty To obtain warranty service contact Customer Service by calling 1 800 634 4350 for the address of the inspection center and the return shipping and handling fee Enclose the original printed rec...

Страница 38: ...al rights and you may have other rights that vary by jurisdiction Because of special local requirements some of the above limitations and exclusions may not apply to you FOR CUSTOMER SERVICE Visit our...

Страница 39: ...thcare conform to this IEC60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than those specified by O...

Страница 40: ...emissions CISPR 11 Group 1 The OMRON BP742CANN including AC adapter uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference i...

Страница 41: ...1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial and or hospital environment Voltage dips short interru...

Страница 42: ...d mobile RF communications equipment should be used no closer to any part of the OMRON BP742CANN including AC adapter and cables than the recommended separation distance calculated from the equation a...

Страница 43: ...be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in t...

Страница 44: ...communications equipment Output Power of Transmitter in Watt Separation distance according to frequency of transmitter in meter 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 5GHz d 2 3...

Страница 45: ...LTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A www omronhealthcare ca 2015 OMRON HEALTHCARE INC M...