6
6.
Securely connect the battery connectors.
①
For the BN150R, fit the battery cables into the clamps on the battery cover.
7.
Attach the front panel.
Insert the front panel from the left side (for the BN75R) or right side (for the BN150R and
BN300R), and fix it with the 2 screws.
Battery replacement is complete.
5.
Attach the battery cover.
<BN75R>
Insert the battery cover from the right side, slide it to the left to align the screw holes, and then
fix the battery cover with the 2 removed screws.
<BN150R and BN300R>
Insert the battery cover from the top side, and slide it to the right to fit into the tabs on the side
of the UPS. Fix the battery cover with the 2 removed screws. Be careful not to tighten the
screws too much; may strip the screw heads.
You may hear a “pop” sound when you connect the battery if it is replaced after the UPS’s
operation is stopped, but this sound is not abnormal.
①
①
<Be sure to reset the battery life counter after replacing the battery.>
After replacing the battery, reset the battery life counter from the “Control” - “Reset B.life
counter” screen in the LCD menu of the UPS.
If you do not reset the battery life counter, a battery replacement alarm may occur earlier
than the expected battery life.
Write the battery replacement date on the included battery replacement date label, and
attach the label to the UPS.
Or, enter the battery replacement date from the “Setting” - “Battery Settings” - “Battery
Installation” screen in the menu on the LCD.