4-139
4-4 Communication Function
4
Func
tions
4-4 Communication Function
• This function allows the Inverter to communicate with an external controller via the RS485 interface
from the TM2 terminal on the Inverter's control terminal block board.
Communication Specifications
Item
ASCII method
ModBus-RTU method
Note
Transmission speed
2400/4800/9600/19200 bps
Select using
the Digital Operator.
Communication
method
Half-duplex communication
Synchronous system
Start-stop synchronous system
Asynchronous system
Transmission code
ASCII code
Binary
Transmission mode
LSB first
Compatible interface
RS-485
Data bit length
7 or 8 bits
8 bits
Select using
the Digital Operator.
Parity
No parity/Even/Odd
Select using
the Digital Operator.
Stop bit length
1 or 2 bits
Select using
the Digital Operator.
Starting method
One-side start using host command
Wait time
10 to 1000 [ms]
0 to 1000 [ms]
Set using
the Digital Operator.
Connection
1:N (N = 32 max.)
Use the Digital Operator
to select a station No.
Error check
Overrun/Framing
BCC/Vertical/Horizontal parity
Overrun/Framing
CRC-16/Horizontal parity
Содержание 3G3RX Series
Страница 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Страница 2: ......
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Страница 22: ......
Страница 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Страница 48: ......
Страница 108: ......
Страница 324: ......
Страница 325: ...Chapter 5 Maintenance Operations 5 1 Protective Functions and Troubleshooting 5 1 5 2 Warning Function 5 10 ...
Страница 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Страница 348: ......
Страница 349: ...Chapter 7 Specifications 7 1 Standard Specification List 7 1 7 2 Dimensional Drawing 7 6 7 3 Options 7 14 ...
Страница 358: ...7 9 7 2 Dimensional Drawing 7 Specifications 3G3RX A2300 A4300 368 79 265 310 10 510 540 2 φ10 195 45 80 265 ...
Страница 360: ...7 11 7 2 Dimensional Drawing 7 Specifications 3G3RX A2550 380 670 700 2 φ12 12 380 480 250 352 79 ...
Страница 361: ...7 12 7 2 Dimensional Drawing 7 Specifications 3G3RX A4750 A4900 2 φ12 2 12 300 390 268 700 79 670 357 ...
Страница 362: ...7 13 7 2 Dimensional Drawing 7 Specifications 3G3RX A411K A413K 2 φ12 2 12 380 480 270 740 79 710 480 ...
Страница 369: ...7 20 7 3 Options 7 Specifications 3G3AX RBC4001 3G3AX RBC6001 100 150 280 300 5 70 100 70 150 390 410 5 ...
Страница 392: ......
Страница 393: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 41 Appendix 3 Life Alarm Output App 42 ...
Страница 436: ......
Страница 437: ...Index ...
Страница 441: ......