Model
3G3AX-MX2-EIP-A
INSTRUCTION SHEET
Thank you for purchasing an OMRON product. Read this
thoroughly and familiarize yourself with the functions and
characteristics of the product before using it. Keep this
instruction sheet for future reference.
OMRON Corporation
© 2011 OMRON Electronics LLC All rights reserved
I37I-E-01
■
General Precautions
The user must operate the product according to the performance
specifications described in this instruction sheet and in the operation
manual of the inverter.
Before using the product under conditions which are not described in the
inverter manual or applying the product to nuclear control systems,
railroad systems, aviation systems, vehicles, combustion systems,
medical equipment, amusement machines, safety equipment, and other
systems, machines, and equipment that may have a serious influence on
lives and property if used improperly, consult your OMRON
representative.
Make sure that the ratings and performance characteristics of the product
are sufficient for the systems, machines, and equipment, and be sure to
provide the systems, machines, and equipment with double safety
mechanisms.
•
The MX2-A
□
inverter with a mounted 3G3AX-MX2-EIP-A option
board is a general purpose product combination. It is a system
component and is used in conjunction with other items of industrial
equipment such as PLCs.
•
A detailed system analysis and job safety analysis should be
performed by the system designer or system integrator before
including the inverter option board combination in any new or
existing system. Consult your OMRON representative for
application specific system integration information if required.
•
The product will be used to control an adjustable speed drive
connected to high voltage sources and rotating machinery that is
inherently dangerous if not operated safely. Interlock all energy
sources, hazardous locations, and guards in order to restrict the
exposure of personnel to hazards. The adjustable speed drive may
start the motor without warning. Signs on the equipment installation
must be posted to this effect. A familiarity with auto-restart settings
is a requirement when controlling adjustable speed drives. Failure of
external or ancillary components may cause intermittent system
operation, i.e., the system may start the motor without warning or
may not stop on command. Improperly designed or improperly
installed system interlocks and permissives may render a motor
unable to start or stop on command.
•
This Instruction Sheet does not contain illustrations of the product
with protective covers removed from the MX2-A
□
inverter. Make
sure that these protective covers are on the inverter before use.
■
Safety Precautions
Definition of Precautionary Information
WARNING
Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury. Additionally, there may be
severe property damage.
Caution
Indicates a potentially hazardous situation,
which, if not avoided, may result in minor or
moderate injury, or property damage.
■
Warnings and Cautions
WARNING
Do not attempt to take an option board apart or
touch any internal parts while the power is
being supplied. Doing so may result in electric
shock.
WARNING
Do not touch the conductive parts such as the
internal PCB or connector while power is being
supplied. Doing so may result in electrical
shock.
WARNING
Do not attempt to disassemble, repair, or
modify an option board. Any attempt to do so
may result in malfunction, fire, or electric
shock.
WARNING
Wiring, maintenance or inspection must be
performed by authorized personnel. Not doing
so may result in electrical shock or fire.
WARNING
Turn OFF the power supply before performing
wiring, maintenance or inspection. Wait for the
time specified on the Inverter front cover for
the capacitors to discharge. Not doing so may
result in electrical shock.
WARNING
Provide safety measures in external circuits,
i.e. not in the option board. This ensures safety
in the system if an abnormality occurs due to
malfunction of the option board or another
external factor affecting the option board
operation. Not doing so may result in serious
accidents.
WARNING
Refer to the section “MX2 Inverter Safety
(ISO 13849-1)” for details if the safety
measures mentioned in the previous warning
are to be ensured using the Gate Suppress
function of the MX2-A
□
inverter.
WARNING
Emergency stop circuits, interlock circuits,
limit circuits, and similar safety measures
must be provided in external control circuits.
WARNING
Fail-safe measures must be taken by the
customer to ensure safety in the event of
incorrect, missing, or abnormal signals
caused by broken signal lines, momentary
power interruptions, or other causes. Not
doing so may result in serious accidents.
Caution
Do not touch the inverter during power-on,
and immediately after power-off. Hot surface
may cause injury.
■
Operating Environment Precautions
Caution
Do not operate the MX2-A
□
inverter with a mounted
3G3AX-MX2-EIP-A option board in the following
locations (doing so may result in malfunction,
electric shock or burning):
•
Locations subject to direct sunlight
•
Locations subject to temperatures or humidity outside the range
specified in the specifications
•
Locations subject to condensation as the result of severe changes in
temperature
•
Locations subject to corrosive or flammable gases
•
Locations subject to dust (especially iron dust) or salts
•
Locations subject to exposure to water, oil, or chemicals
•
Locations subject to shock or vibration
Caution
Take appropriate and sufficient countermeasures
when installing systems in the following locations
(doing so may result in malfunction):
•
Locations subject to static electricity or other forms of noise
•
Locations subject to strong electromagnetic fields
•
Locations subject to possible exposure to radioactivity
•
Locations close to power supplies
Caution
The operating environment of the MX2-A
□
inverter
with a mounted 3G3AX-MX2-EIP-A option board
can have a large effect on the longevity and
reliability of the system. Improper operating
environments can lead to malfunction, failure, and
other unforeseeable problems with the system.
Make sure that the operating environment is within
the specified conditions at installation and remains
within the specified conditions during the life of the
system.
■
Application Precautions
WARNING
Failure to abide by the following precautions
could lead to serious or possibly fatal injury.
Always read these precautions.
•
Always connect the grounding cable to one of the ground terminals of
the MX2-A
□
inverter.
•
Check any user program in the system that acts as a EtherNet/IP
master before actually running it. Not checking the program may
result in unexpected operation.
Caution
Failure to abide by the following precautions could
lead to faulty operation of the option board or the
inverter, or could damage either of the two. Always
read these precautions.
•
Install external breakers and take other safety measures against
short-circuits in external wiring. Not observing this may result in
burning.
•
Be sure that all the cable connector screws are tightened to the
torque specified in the relevant manuals. Incorrect tightening torque
may result in malfunction.
•
Do not allow metal clippings to enter either option board or inverter
when wiring or installing the unit.
•
Follow the network configuration and wiring instructions provided in
the “EtherNet/IP Operation Manual” (Cat. No. W465).
o
Wire the EtherNet/IP cables correctly. Incorrect wiring may result
in burning.
o
Wire the EtherNet/IP connectors correctly. Incorrect wiring may
result in burning.
o
Apply termination at both ends of a EtherNet/IP cable segment.
Do not apply termination anywhere else.
•
Be sure that the option board is mounted correctly. Improper
mounting may result in malfunction.
•
Disconnect the grounding cable when performing withstand voltage
tests. Not disconnecting the grounding cable may result in burning.
•
Check the inverter settings for proper inverter behaviour before
actually operating the inverter remotely via the EtherNet/IP network.
•
Check the network related inverter settings regarding EtherNet/IP
node address and EtherNet/IP remote I/O allocation. Not doing so
may result in unexpected operation.
•
Check the inverter’s EzSQ program and its interaction with the
EtherNet/IP master before actually running it on the inverter. Not
checking the program may result in unexpected operation.
•
When replacing an inverter be sure that all inverter settings of the
inverter being replaced are restored to the replacement.
•
Parameters for the module are stored in the module and must be
restored if the module is replaced. The setup parameters for the
3G3AX-MX2-EIP-A are not stored in the drive. Always check the
node address and other network related inverter settings after
restore.
•
Confirm that no adverse effect will occur at the moment the
EtherNet/IP master stops communicating with the inverter or at the
moment the EtherNet/IP master has not yet started communicating to
the inverter.
•
Confirm that no adverse effect will occur in the inverter before force-
setting/force-resetting any bit in the system that acts as a EtherNet/IP
master.
■
Handling, Storage and Disposal
•
Before touching the option board or inverter, be sure to first touch a
grounded metallic object in order to discharge any static built-up. Not
doing so may result in malfunction or damage.
•
When transporting or storing the option board, cover the PCBs with
electrically conductive materials to prevent electronic components
from being damaged by static electricity. Also keep the product within
the specified storage temperature range.
•
Never dispose electrical components by incineration. Contact your
state environmental agency for details on disposal of electrical
components and packaging in your area.
■
Compliance with EC Directives
•
This product complies with EC Directives when mounted on an
MX2-A
□
inverter and having connected the grounding cable. For
grounding, cable selection, and any other conditions for EMC
compliance, refer to the MX2 User’s Manual for installation.
■
References
Please be sure to read the related user manuals to use the
3G3AX-MX2-EIP-A option board safely and properly. Be sure you
are using the most current version of the manual.
Name
Cat No.
3G3AX-MX2-EIP-A Option Board User’s Manual
I36I
MX2 User’s Manual
I570
EtherNet/IP Operation Manual
W465
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes,
or regulations that apply to the combination of products in the customer’s
application or use of the products.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE
RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also product catalogs for Warranty and Limitations of Liability
.