background image

 

 

Connection manual of XDesignerPlus external devices

 

3 / 12 

2. Selecting TOP model and external devices 

Select the external devices to connect to TOP.. 

 

 

 

Settings details 

Contents 

TOP 

Series 

Select the name of a TOP series that is to be connected to PLC. 
efore downloading the settings, install the OS version specified in the table below according to 
TOP series. 

Series 

Version name 

XTOP / HTOP 

V4.0 

 
 

Name 

Select the model name of TOP product. 

External device 

Vendor 

Select the vendor of external devices to be connected to TOP. 
Select “OMRON Industrial Automation”. 

PLC 

Select the model series of external devices to be connected to TOP. 
Select “CAM Positioner Series 3F88L-160/162”.   
Please check, in the “1. System configuration”, if the relevant external device is available to set a 
system configuration.. 

Содержание 3F88L-160

Страница 1: ...l devices Page 3 Select a TOP model and external devices 3 Example of system settings Page 4 Explains an example of settings for communication interface between the devices and the relevant external t...

Страница 2: ...and OMRON Corporation CAM Positioner Series 3F88L 160 162 is as follows Series CPU Link I F Communicati on method Systemsettings Cable CAM Positioner 3F88L 160 162 Communication Port on CPU Unit RS 23...

Страница 3: ...S version specified in the table below according to TOP series Series Version name XTOP HTOP V4 0 Name Select the model name of TOP product External device Vendor Select the vendor of external devices...

Страница 4: ...BPS 9600 User settings Serial data bit Bit 7 User settings Serial stop bit Bit 2 User settings Serial parity bit Bit EVEN User settings 1 XDesignerPlus settings After setting the below details in Proj...

Страница 5: ...rnal devices as shown below Please refer to the User s Manual of external devices for more detailed settings 1 Set Function No b Parameter No 6 as 1 Set the Parity bit 9600 bps factory setting 2 Switc...

Страница 6: ...erface settings Details Contents Signal level Select a serial communication method between TOP External devices COM1 supplies RS 232C only Baud rate Select a serial communication speed between TOP Ext...

Страница 7: ...1 mSec Set the TOP s wait time between receiving the response from external devices transmitting the next command request at 0 5000 x 1 mSec TOP COM 2 1 It is the interface settings of TOP for externa...

Страница 8: ...It is an error in the settings of a TOP external device and cable reference communication check sheet Communication check sheet Please check the settings shown in the sheet below if there is an error...

Страница 9: ...s seen at the connection area of cable connection connector B XTOP COM 2 port 15pin XTOP COM2 Cable connection PLC PIN arrangement Note1 Signal name Pin number Pin number Signal name PIN arrangement N...

Страница 10: ...rigin compensation value 4 digit BCD from 0000 to 0359 0719 Address 0002 Leftmost byte Address 0003 Rightmost byte X 0004 0005 Backlash Compensation value Backlash compensation value 4 digit BCD from...

Страница 11: ...s for bank1 Address 0070 to 0073 Bank 7 cam data protect setting Address 0074 to 0077 Bank 7 one direction function setting Address 0078 to 007B Bank 7 rotation direction setting X 0080 to 008B Bank8...

Страница 12: ...for Bank 8 Same as for Bank 1 X Note1 The 8 digits of data can be read when the P0000 address uses 32BIT Controller Status Read RUN PRGM SET S Address Name Detailed information 32 BIT available Status...

Отзывы: