SCCB Interface
Version 1.1, December 7, 2004
Proprietary to OmniVision Technologies
41
O
mni
ision
10.1.1 Register Reset
All registers can be reset to their default values by using the RESET pin (RESET to VDD_IO) or by
using the SCCB interface (see register
[7] (0x12)). OmniVision suggests putting the reset
register setting (set register
(0x12) to 0x80) at the beginning of the sensor initialization. After
software reset, wait 1 ms for the next register access (there is no limitation for other register
settings).
10.1.2 Standby Mode Enable
The OV9650 C
AMERA
C
HIP
can be placed in Standby mode by using the PWDN pin (PWDN to
VDD_IO) or by using the SCCB interface (see register
[4] (0x09)). Note that using the PWDN
pin results in lower Standby current (see Electrical Characteristics in the
OV9650 Datasheet
).
Setting register
[3] (0x39) to high before standby can reduce the current a little bit.
10.1.2.1 Standby Mode Using the PWDN Pin
Internal device clock is halted and all internal counters are reset to their default values and all SCCB
registers remain unchanged.
10.1.2.2 Standby Mode Using the SCCB Interface
Suspends internal circuit activity but does not halt the device clock.
10.1.3 Tri-state Enable
This bit control will immediately tri-state the data outputs. However, all internal signals will continue
to be generated and transfer to the output as if it were active. It is the user’s responsibility to ensure
that the tri-state command is used after all functions have completed their operation.
If the device is put into Standby mode, all outputs, including data and clock, are automatically
tri-stated.