Omnitronix DATA-LINK DL50 Скачать руководство пользователя страница 21

 

Manual Rev. 1.01 

Page 19 

Chapter 4    

Setup 

4.1 -  Main Menu 

Overview 

The setup menu contains all of the configuration options available on the DL50.  It is organized in 
a logical tree structure with all settings classified under the following groups: 

 

Data-Link DL50 - Main Setup Menu 

A) Network Settings 

B) Serial Settings 

C) Modem Settings 

D) Passwords/Security 

E) Alarm Definitions 

F) Action Definitions 

G) System Date/Time 

H) Polling/Other Settings 

 

Each subsequent section in this chapter will go over one of the above setup branches, outlining 
each option within. 

Note:  

Pressing <CTRL + C> while in the setup menu will immediately exit the menu tree and display 
the command prompt. 

Since this product allows for multiple simultaneous command processes, two administrators could 
conceivably change the same option at the same time, but due to the multitasking nature of the 
DL50, the changes are processed in the order received. 

Note:  

The DL50 processes setup changes in real time.  In other words, the unit implements changes to its 
setup as soon as they are entered.  There is no need to exit the setup menu or reboot the unit to 
apply changes.  The only exception to this rule is that of IP-specific network settings.  Changes to 
these settings are implemented only after all open Telnet  command processors are closed. 

Option Types 

There are several different types of inputs employed within the setup menu.  The most common is 
the string type entry: 

A) 

Unit ID

                             [Data-Link] 

When selected, this setting will provide a prompt requesting a new value.  At this point, press 
<ENTER> to abort the option entry or press <SPACE> and <ENTER> to delete the current value 
and leave it blank.  Some numerical or required settings will not allow an administrator to leave an 
option blank, so be aware when attempting to delete a setting’s value. 

Содержание DATA-LINK DL50

Страница 1: ...t Seattle Washington 98109 U S A Tel 206 624 4985 Fax 206 624 5610 info omnitronix com www omnitronix com User s Manual User s Manual User s Manual User s Manual Installation and Operation Guidelines...

Страница 2: ...nly and is subject to change without notice Examples data and names used in this manual are examples and fictitious unless otherwise noted No part of this document may be reproduced or transmitted by...

Страница 3: ...gs 25 4 5 Passwords Security 26 4 6 Alarm Definitions 27 4 7 Action Definitions 32 4 8 System Date Time 33 4 9 Polling Other Settings 33 Chapter 5 Programming Data Alarms 35 5 1 Introduction 35 5 2 In...

Страница 4: ...Omnitronix DL50 User s Manual Page 2...

Страница 5: ...Female DB9 Null Modem serial cable Included PC running Omnitronix AlarmManager software Software may be obtained at http www omnitronix com or by contacting Omnitronix Technical Support Data checklis...

Страница 6: ...Data Alarm 2 OFF Full 01 Release mode LINE Modem NONE Duplex FULL Network Yes Password ON IP Add 192 168 105 12 Compress OFF MAC Add 00 11 C3 A1 2F 0F Port 1 Port 2 Baud Rate 19200 19200 Parity etc 8...

Страница 7: ...nical support 6 Verify the PC running AlarmManager by repeating step 3 with the IP address of that computer The output from this command should be similar to that of the previous ping 1 4 Data Alarms...

Страница 8: ...and enter Data Alarm 1 10 Select Actions and enter T1 to cause this data alarm to send a trap to SNMP manager 1 as configured in the SNMP managers menu 11 Select Alarm Equation and enter test_field t...

Страница 9: ...lowing methods can be used to either access the command port or provide a pass through connection to devices attached to the serial ports All methods of connecting to the unit can be secured via passw...

Страница 10: ...thernet adapter 33 6Kbps modem or external modem adapter 48VDC power receptacle no power supply 5VDC power receptacle and power supply The DL50 may come with any of the following accessories as well d...

Страница 11: ...ates green and red These LEDs can be used to verify that a cable is connected the LED is lit and that data is being transmitted or received the LEDs flicker between red and green I O 2 has a CTS2 LED...

Страница 12: ...connection of the cable with the DL50 serial port connectors Default settings for the serial ports are 19200 baud 8 bit word length no parity and one stop bit 19200 8N1 Use either the internal setup...

Страница 13: ...able outlines the functionality of Dipswitches B1 through B6 in switching the baud rate and port settings of I O 2 Baud Rate SW1 SW2 SW3 Word Parity Stop SW4 SW5 SW6 9600 OFF OFF OFF 7 Bits None 1 OFF...

Страница 14: ...s Remote Access The DL50 provides an administrator with transparent access to devices connected to the serial ports of the unit via pass through connections These can be accessed via the command proce...

Страница 15: ...the DL50 allows is PING and FTP push Password Protection The DL50 has two different access levels available user and administrator The unit allows for up to two different user level passwords Each of...

Страница 16: ...Omnitronix DL50 User s Manual Page 14...

Страница 17: ...hes B7 and B8 are off in order to enable command mode By default serial port command processor access is not password protected Once connected the command line is available in system administrator mod...

Страница 18: ...tions PORT Function 21 Internal FTP server reserved for future use 23 Telnet to local command port 2001 Telnet to local command port 210n The n corresponds to the serial port number to connect a pass...

Страница 19: ...me are displayed for user informational purposes Memory indicates the amount of data ready memory installed on the DL50 Full indicates the percent of the memory installed that is currently occupied by...

Страница 20: ...ord length parity and stop bit settings for each installed serial port File Records shows the number of carriage return delimited records stored within the unit File Bytes represents the number of byt...

Страница 21: ...at the same time but due to the multitasking nature of the DL50 the changes are processed in the order received Note The DL50 processes setup changes in real time In other words the unit implements c...

Страница 22: ...ctions require T followed by the number s of the trap managers to be used as they are defined in the network setup menu Valid options are 1 and 2 as there are two different SNMP managers definable wit...

Страница 23: ...ress and other network settings should often be set only once and then only changed if the unit is moved or the network architecture is changed Usually the default value of 255 255 255 0 is appropriat...

Страница 24: ...Minutes Between Push Attempts has a valid range of 1 to 9999 minutes FTP Push Setup Select Files to Push brings up the menu in the following example Each item in the menu is a toggle for the specifie...

Страница 25: ...al Time Socket Setup Show Answer String on Connection toggles a standard answer string that can appear upon connection to an RTS Real Time Socket Setup Require Password on Connection toggles password...

Страница 26: ...igures whether or not the newest data received on the port will overwrite the oldest in the event that the file reaches its capacity Time Stamping adds the date and time received to each record as it...

Страница 27: ...s a toggle with the following options Command Data and Inline Command allows for serial command processor access Data configures the port as an inbound data port just like port 1 and Inline causes the...

Страница 28: ...connected without any activity This setting is measured in minutes If set to zero this feature is disabled 4 5 Passwords Security This setup branch controls all of the primary access and security issu...

Страница 29: ...matically granted admin access Dialback Security Setup brings up the following menu Data Link DL50 Dialback Security Menu A User 1 Phone Number B User 2 Phone Number C Dialback Security Enable OFF Bot...

Страница 30: ...15 OFF P Alarm 16 OFF Q Setup Alarm Fields R Display Alarm Status In the example above alarms four through fourteen were cut out for brevity Data Alarm n Settings Alarm n contains the settings for eac...

Страница 31: ...to be delivered via serial port 2 during a serial action for this alarm Alarm n Clear This Alarm Counter Now allows the administrator to clear the counter for the selected data alarm manually Data Ala...

Страница 32: ...Add Exclusion O Delete Exclusion 01 01 07 04 09 02 11 28 12 25 No Data 1 Alarm Settings Alarm Enable toggles the no data monitor on or off No Data 1 Alarm Settings Alarm Actions defines actions to pe...

Страница 33: ...Message Event 1 Default Message D Event Time Sunday DISABLED E Event Time Monday DISABLED F Event Time Tuesday DISABLED G Event Time Wednesday DISABLED H Event Time Thursday DISABLED I Event Time Frid...

Страница 34: ...previous attempts fail Callout Delay is the number of seconds to wait between callout attempts Modem Callout Number n sets the phone number to call for each modem action Pager Number n brings up the...

Страница 35: ...t 2 00 a m local standard time which becomes 3 00 a m local daylight time On the last Sunday in October clocks are set back one hour at 2 00 a m local daylight time which becomes 1 00 a m local standa...

Страница 36: ...toggle controlling whether the unit will automatically delete each record as it is successfully polled via Xmodem or CBB CBB DLE Stuffing is a CBB specific configuration option CBB Retransmits is a C...

Страница 37: ...gurable collections of 16 data alarms Each of these collections is referred to as a data alarm family in this manual A port may only be monitored by one family at a time but it is possible to assign f...

Страница 38: ...ed operators and their function Operator Function Greater Than Less Than Greater Than or Equal to Less Than or Equal to or Not Equal to Equal to Single character wildcard matches any character or spac...

Страница 39: ...e for this Data Alarm The name entered is most beneficial if descriptive of the particular data portion monitored for alarms 4 Select Alarm Equation and enter the following Test_Field Sesame 5 Toggle...

Страница 40: ...Omnitronix DL50 User s Manual Page 38...

Страница 41: ...ax DUPLEX FULL HALF Set the command processor echo setting for the current connection method Command EXIT Function EXIT CONSOLE MODE Syntax EXIT Ends the console session Command HELP Function SHOW HEL...

Страница 42: ...leges Command USER Function SWITCH TO USER PRIVILEGES Syntax USER Change the user level to basic user with no password prompt 6 2 Data Release Commands The following settings are accessible by all use...

Страница 43: ...released or display current state Command FREE Function CHECK FREE SPACE Syntax FREE Display the amount of remaining memory in the record database Command NEXT Function SEND NEXT DATA BLOCK Syntax NEX...

Страница 44: ...x WAIT ON OFF Enable disable waiting for NEXT command to release data or display current state 6 3 Setup Commands The following settings are accessible only with administrative privileges Command DEFA...

Страница 45: ...ALLY Syntax BYPASS port number Provide pass through operation between the console port and the specified port If no port is specified uses the port associated with the current ACCESS file Command COLD...

Страница 46: ...CLEAR UNIT Syntax ZAP Clear all data and restore all settings to factory default values Records are recoverable Requires confirmation if Confirm Before Deletion menu option is enabled Command ZERO Fu...

Страница 47: ...l Tab 10 LF Line Feed 11 VT Vertical Tab 12 FF Form Feed 13 CR Carriage Return 14 SO Serial In Shift Out 15 SI Serial Out Shift Out 16 DLE Data Link Escape 17 DC1 XON Device Control 1 18 DC2 Device Co...

Страница 48: ...59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E ASCII Value Character 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _ 96 97 a 98 b...

Страница 49: ...e telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notification is not possible you will be notified as soon as possible Your telephone...

Страница 50: ...Omnitronix DL50 User s Manual Page 48...

Страница 51: ...make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate The Load Number LN assigned to each terminal device denotes the percenta...

Страница 52: ...s ensemble Cette pr caution est particuli rement importante dans les r gions rurales Avertissement L utilisateur ne doit pas tenter de faire ces raccordements lui meme il doit avior recours a un serv...

Страница 53: ...ervice under this warranty This warranty applies if your DL50 fails to function properly under normal use and within the manufacturer s specifications This warranty does not apply if in the opinion of...

Страница 54: ...Omnitronix DL50 User s Manual Page 52...

Страница 55: ...0 40 40 40 COLDSTART COLDSTART COLDSTART COLDSTART 43 43 43 43 Command Line 4 Command Processor 16 Compress 18 Compressed Line Mode 12 33 34 Confirmation 33 34 43 44 COUNT COUNT COUNT COUNT 41 41 41 4...

Страница 56: ...USHTEST 43 43 43 43 Q Queued Alarms 42 R Rack Mount 8 Real Time Socket 15 16 21 22 23 26 27 Real Time Socket 15 Release Mode 17 33 34 Remote Access 12 Remote File Names 22 RESEND RESEND RESEND RESEND...

Страница 57: ...USER 13 40 40 40 40 User Access 15 26 User Level Passwords 13 W Wildcard 36 Word Length 18 Wrap 24 25 WRA WRA WRA WRAP P P P 44 44 44 44 X Xmodem 12 17 18 34 43 Xon Xoff 23 24 Z ZAP ZAP ZAP ZAP 44 44...