00031461.DOC, Version 1.1
53/56
9.5.5 Individual title sequence
1. Activate program mode with button Program. The display indicates
PROGRAM
[e]
, the title number
[
c
]
of
the first title and the storage space number
[
j
]
.
2. Select the first title for the sequence.
3. Confirm with button Enter. The display indicates the next storage space number 2
[
j
]
.
4. Repeat steps 2 and 3 until the desired title sequence has been programmed.
5. To start the title sequence, press button
►
/
II
. The display indicates
MEMORY
[k]
.
6. The
buttons
allow for selection of each title of the sequence. By keeping one of the buttons
pressed, fast forward or reverse within a title can be activated.
7. After replaying the title sequence or by pressing the Stop/Eject button once, the CD player is set to stop.
To start the replay of the title sequence again, press button
►
/
II
.
8. Press button Program, to return to normal operating mode. The indication
MEMORY
[k]
on the display
goes off. The program is now deleted.
9.5.6 Repeat functions/ function Shuffle
After switching on the unit, mode
REPEAT ALL
is always activated. Further repeat functions and the replay in
random order (function Shuffle) can be selected by pressing button RPT/SHUF repeatedly. The selected
function is shown on the display by the corresponding indication
REPEAT
[k]
or
SHUFFLE
[k].
1. keystroke (indication
SHUFFLE
): replay in random order (function Shuffle)
next keystroke: function Shuffle deactivated, no repeat function activated
next keystroke (indication
REPEAT 1
): repeat of current title
next keystroke (indication
REPEAT
): repeat of all titles of the current folder in case of MP3 CDs
next keystroke (indication
REPEAT ALL
): repeat of all titles
9.6 Wireless microphone HM-105
1. Keep the On/Off button pressed for 2 seconds to switch on the microphone. The power indicator lights
red. The display indicates
O
n
, followed by the channel adjusted and the battery status.
The display goes
off if no button is pressed within 5 seconds. It can be switched on again by pressing any button.
2. To select a transmission channel keep the Set button pressed until the channel indication starts flashing.
It keeps flashing for approx. 10 seconds. During that time, the channel can be adjusted with buttons
▲
and
▼
. Press the Set button to confirm the channel selection (within 10 seconds) otherwise the
microphone returns to the channel previously adjusted.
3. The display can indicate the radio frequency for the adjusted channel. As long as one of the buttons
▲
and
▼
is pressed, the display indicates the frequency instead of the channel. (Please refer to chapter
11.1 Channel configuration
for a table listing which channel is assigned to which frequency).
4. The sensitivity of the microphone can be adjusted in two steps with the Sensitivity switch (upper position:
high sensitivity, central position: low sensitivity). Thus, the volume level of the microphone can be
readjusted. Reduce the sensitivity if the volume of the microphone signal is too high and thus distorted.
Increase the sensitivity if the volume is too low and a poor S/N ratio results.
5. To mute the microphone during operation, set the Mute switch to its lower position. Then, no sound will
be transmitted.
6. To switch off the microphone, keep the On/Off button pressed for approx. 2 seconds until the display
indicates
OFF
. If the display indicates
Err
(Error) when switching off, press buttons Set,
▲
and
▼
simultaneously to switch off the microphone. If the microphone is microphone is switched off
automatically after a short time, keep buttons On/off, Set
▲
and
▼
pressed simultaneously, until the
display indicates
O
n
. Then, normal operation is possible again. If it is not possible to eliminate the fault by
these measures of if other malfunctions occur, remove the batteries and reinsert them.