8 PROBLEM CHART
PROBLEM
CAUSE
REMEDY
The power does not
turn on.
•
The power cable is not connected.
•
Connect the cable to a power outlet.
There is little or no
sound.
•
The input selector switch is in the
wrong position.
•
The rear input selector switch
PH/LINE is set to LINE although a
turntable is connected.
•
The connection cable was not
connected properly or not connected at all.
•
The terminal or plug is dirty.
•
The master level is too low.
•
Set the selector switch to the correct
signal source.
•
Set the input selector switch PH/LINE
to PH.
•
Connect the cable properly.
•
Clean and reconnect.
•
Increase the level with the master
control or control.
There is noise or
distortion.
•
The master level is too high.
•
The input level is too high.
•
The rear input selector switch
PH/LINE is set to PH although a unit
with line level output is connected.
•
Via the output meter, adjust the
master level to an optimum level with
the master control.
•
Via the level indication, adjust the
channel to an optimum level with the
gain control.
•
Set the input selector switch PH/LINE
to LINE.
Crossfading does not
work.
•
The assignment of the assignment
switches overlaps.
•
Select the correct signal sources for
crossfading with the assignment
switches.
Содержание PM-3010