background image

English

9

INPUTS
A good cable run improves the sound quality remarkably. Input cables should be short and direct, since high
frequencies will be mostly be absorbed if the cables are unnecessarily long. Besides that a longer cable may
lead to humming and noise trouble. If long cable runs are unavoidable, you should use balanced cables.
The inputs of your OMNITRONIC PA 240 are equipped with 6.35mm and Cinch jacks.

OUTPUTS
The high damping factor of your amplifier supplies a clear sound reproduction. Unnecessarily long and thin
cables will influence the damping factor and thus the low frequencies in a negative way. In order to safeguard
good sound quality, the damping factor should lie around 50. The longer a cable has to be, the thicker it
should be.
The outputs of your OMNITRONIC 200 are equipped with Screw/clamp jacks.

CONNECTION TO THE MAINS
Connect the OMNITRONIC PA 240 only after having made sure that the right voltage (220/230V) is supplied
and that the ground lead is earthed. This device falls under potection class I. Do not detach the ground lead
from the housing!
This device features a 4A fuse.

STEREO OPERATION
Connect the input signal to the input jacks on the rearpanel.
Connect your speakers to the Screw/clamp jacks Output Channel 1 and Output Channel.
Caution! The impedance of the speakers must be between 4 and 16 Ohm.
Caution! Before switching on your amplifier, please refer to the explanations under Operation.
Adjust the level of each channel with Gaincontrol CH1 and CH2 on the frontpanel.
Caution! Increase the level of each channel only so far that the Clip LED lights up shortly. Thus, you avoid
that the output signal is distorted and your speakers are damaged.

OPERATION
After having connected your amplifier to the mains, turn both gain controls counter-clockwise to null-position.
The last device to be switched on is the amplifier. The "power on" LED lights up now. If it does not, check if
the amplifier is connected to the mains correctly.
After the turn-on delay the speakers are activated.
After having set the volume controls of the pre-amplifier in null-position, turn the gain controls of your amplifier
to mid-position. You must not hear any loud humming. If there is humming nevertheless, check the connec-
ting cables between the pre-amplifier and the amplifier. Now adjust the volume with the gain controls CH1 and
CH2.
All important operating modi of the amplifier are displayed on the frontpanel.

CLIP

short-circuit or impedance too low or signal distorted

-20 dB

input signal available

PROTECT

active during stabilisation period after switching on or when one of the 
protective circuits started

POWER

amplifier is online

THERMAL

when overheated

If you want to switch off the system, switch off the amplifier first and then the pre-amplifiers in order to
avoid acoustic shocks on the speakers.

MAINTENANCE
The ventilation grille has to be cleaned regularly. Never use aggressive detergents - simply use a damp cloth
instead

Содержание PA-240

Страница 1: ......

Страница 2: ...n English The rear panel printing of the power amplifier next to the output sockets is unclear The occupation of the channels A and B is as illustrated in the illustration above The minimum impedance...

Страница 3: ...NITRONIC PM 520 PRO Pro Mixer 10006821 OMNITRONIC PM 640 PRO Pro Mixer 10006840 PLATTENSPIELER TURTABLES PLATINES OMNITRONIC DD 1215 incl System 10603027 OMNITRONIC DD 1220 incl System 10603030 OMNITR...

Страница 4: ...ndler in Verbindung SICHERHEITSHINWEISE Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen m...

Страница 5: ...eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind GER TEBESCHREIBUNG Die OMNITRONIC PA 240 ist f r den professionellen Anwendungsbereich vorgesehen Die Anschl sse be finde...

Страница 6: ...t Channel 2 an Achtung Die Impedanz der angeschlossenen Lautsprecher mu zwischen 4 und 16 Ohm liegen Achtung Bevor Sie die Endstufe einschalten beachten Sie bitte die Erl uterungen unter Bedienung Ste...

Страница 7: ...r TECHNISCHE DATEN OMNITRONIC PA 240 Spannungsversorgung 230 V 50 Hz Spannungsfestigkeit 230 V 10 207 V 253 V Gesamtanschlu wert max 350 W Kurzfristige Spitzenleistung bei 1 KHz 170 W 4 Ohm Maximallei...

Страница 8: ...STRUCTIONS This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the sa...

Страница 9: ...rear panel the gain controls on the front panel The OMNITRONIC PA 240 is sustained short circuit proof protected against overtemperature and features turn on delay and load independent clipping LEDs...

Страница 10: ...lifier please refer to the explanations under Operation Adjust the level of each channel with Gaincontrol CH1 and CH2 on the frontpanel Caution Increase the level of each channel only so far that the...

Страница 11: ...wer consumption max 350 W Momentary music peak power at 1 KHz 170 W 4 Ohms Maximum power output 2 x 170 W 4 Ohms Nominal power output 2 x 120 W 4 Ohms Power output sine Stereo 4 Ohm 2 x 120 W Stereo 8...

Страница 12: ...de montage ou d utilisation n est pas couvert par la garantie L appareil ne devrait pas tre mis en service lorsqu il a t transport d un endroit froid un endroit chaud Il se forme de la condensation qu...

Страница 13: ...A 240 sont quip s avec douilles VIS DE SERRAGE CONNEXION AU SECTEUR Brancher le OMNITRONIC PA 240 seulement au r seau apr s avoir assur une tension de r seau de 220 230V et une protection de terre L a...

Страница 14: ...ux 1 KHz 100 dB Tension minimale de l entr e 0 6 V Impedance de l entr e 50 kOhm Resistance interne 0 25 Ohm Douilles d entr e 2 douilles jack 2 douilles cinch Douilles de sortie 2 zones d enceintes a...

Отзывы: