10603004X31NXS_V_1_0.DOC
23/43
Make sure that the scale ring points to the front.
Adjusting the counterweight
• Remove the stylus cover.
• Set the Anti-skating-wheel to the 0 position.
• Set the tonearm lift to the down position
• Release the tonearm from the armrest and move it to a position between the turntable and the armrest.
Make sure that you do not damage the stylus.
• Carefully hold the tonearm and adjust the counterweight by turning it clockwise or anti-clockwise
respectively. The tonearm should be balanced to a horizontal position.
• Move the tonearm back to the armrest and clamp it.
• Put the stylus cover on the stylus.
• Set the scale on the counterweight to the 0 position without turning the counterweight.
Caution:
Hold the counterweight with one hand in order not to change the balanced setting (stylus pressure = 0). Only
move the scale ring.
• Turn the counterweight clockwise until the scale shows the value corresponding to the pressure of the used
stylus. Please follow the pick-up system manufacturer's instructions.