iConverter
TM3 Transport Module
Quick Start Guide
PRODUCT OVERVIEW
This document describes the basic installation and configuration of the TM3 Transport
module.
The
iConverter
Modular T1/E1 Multiplexer transports up to sixteen T1/E1 circuits and
10/100/1000 Ethernet over a fiber transport link or CWDM channel. This flexible and scalable
system is comprised of an
iConverter
TM3 fiber transport module, and one or more
iConverter
4xT1/E1 MUX modules installed in a 2, 5 or 19-module chassis.
For the complete User Manual on this product, access Omnitron’s secure download site
and request access.
http://www.omnitron-systems.com/login.php
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Module in Chassis and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation
1) CONFIGURE DIP-Switches
DIP-SWITCH BANK 1
The function of DIP-switch Bank 1 is outlined in Figures 1 and 2 below.
Switch Down (Default)
Up
SW6
SW7
SW8
Link Mode
1
AN:
P1 Auto-neg.
Man:
P1 Manual
Down Down Down
Link Segment (LS)
2
AN:
P2 Auto-neg.
Man:
P2 Manual
Up
Down Down
Link Propagate (LP)
3
1000:
P2 1000Mbps
10-100:
P2 10 or 100Mbps
Down
Up
Down Remote Fault Link
Segment (RFD+LS)
4
100:
P2 100Mbps
10:
P2 10Mbps
Up
Up
Down Remote Fault Link
Propagate (RFD+LP)
5
FDX:
P2 Full-Duplex
HDX:
P2 Half-Duplex
Down Down
Up
Symmetrical Fault Detect (SFD)
6
Link Modes (see Figure 2)
Up
Down
Up
Asymmetrical Link Propagate Port
1 to Port 2 (ALP P1 P2)
7
Down
Up
Up
Asymmetrical Link Propagate Port
2 to Port 1 (ALP P2 P1)
8
Up
Up
Up
Asymmetrical Link Propagate Port
1 to Port 2 + Port 1 Remote Fault
Detect (ALP P1 P2 + P1 RFD)
Figure 1: DIP-switch Bank 1
Figure 2: Link Mode Settings
3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE
To access the Command Line Interface (CLI), connect the TM3 RS-232 Serial Console
Port to the COM port of a computer equipped with terminal emulation software such as
HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can be
changed to a DB-9 connector with the included adapter. The TM3 Console Port is a standard
RS-232 asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:”
window. Set the serial port to the following:
Bits Per Second
57,600
Data Bits
8
Stop Bits
1
Parity
NONE
Hardware Flow Control
NONE
Once connected, press <ENTER> to bring up a command line prompt on the attached PC.
A new TM3 module does not have a password, and will skip the Password Entry screen and
go straight to the Management Options screen. If a password has been set, the Password
Entry screen will be displayed. Type the password and press <ENTER>, the TM3 will respond
with the Management Options screen.
The CLI interface enables detailed configuration of the module.
4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is
operational by viewing the LED indicators.
LED Function
“Legend”
Color
OFF State
ON/Blinking State
Power
“PWR”
Green
No power
ON: Module has power
P1 Link Activity
“100”
Green
Port not linked at 100M
ON: Port linked at 100M
Blinking: Data activity
P1 Link Activity
“1000”
Green
Port not linked at 1000M
ON: Port linked at 1000M
Blinking: Data activity
P1 Link Activity
“100” and “1000”
Green
Port not linked at 10M
ON: Port linked at 10M
Blinking: Data activity
Test/Alarm
“Tst/Alm”
Green
Reserved
Reserved
Management Mode
“Msr/Slv”
Green
Slave Mode
ON: Master (normal)
5 Hz Blinking: Secure Slave
P2 Link Activity
“100”
Green
Port not linked at 100M
ON: Port linked at 100M
Blinking: Data activity
P2 Link Activity
“1000”
Green
Port not linked at 1000M
ON: Port linked at 1000M
Blinking: Data activity
P2 Link Activity
“100” and “1000”
Green
Port not linked at 10M
ON: Port linked at 10M
Blinking: Data activity
Figure 5: LED Indicators
040-2420T-002C 06/13