Page 12

2) Installing the Module

Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters 

(6.6 feet) from the floor.  Use the four mounting holes on the module to secure the 

module to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side 

and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on 

the module. 

Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8260-0).  

Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper 

installation guidelines.
Follow the same guidelines above when rack mounting the module.

3) Apply Power

AC Power

Secure the ground wire to the ground screw.  See the figure below for the location 

of the grounding screws.
Route the power cord through the provided strain relief for additional support and  

connect the barrel connector at the end of the wire on the AC/DC adapter to the 

barrel connector on the module.  Connect the AC/DC adapter to the AC outlet.  

Confirm that the module has powered up properly by checking the Power LED 

located on the front of the switch.

AC Models Rear View: Barrel Connector for AC/DC Power Adapter

NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

Page 11

DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.

Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

The 6 Port G/M re12 to +57VDC inclusive of tolerances( 0.68A @ 12VDC 

max rated power).  The 10 Port G/M re12 to +57VDC inclusive of tolerances 

(0.75A  @  12VDC  max  rated  power).  See  specification  table  for  specific  model 

requirements. 
Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

DC Models Rear View: 2-Pin Terminal for DC Power

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

Содержание OmniConverter G/M

Страница 1: ...can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option r...

Страница 2: ...ssible DIP switches or using Web Telnet SSH SNMPv1 v2c v3 or Serial Console management interfaces These management interfaces provide access to filtering and security options such as broadcast storm p...

Страница 3: ...set Button A reset button is available on the front of the module to restore the module to factory default values Press and hold the reset button for more than 5 seconds to restore the module to facto...

Страница 4: ...configured for Directed Switch Mode traffic from all the RJ 45 user ports is only forwarded to the uplink port F1 preventing the broadcast traffic from flooding other network ports Incoming traffic f...

Страница 5: ...P Redundant Mode return to primary F1 Uplink Redundancy Page 10 When configured for Uplink Redundant Mode no return to primary the uplink ports operate as redundant links A fault on the primary Port F...

Страница 6: ...LED located on the front of the switch AC Models Rear View Barrel Connector for AC DC Power Adapter NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY OPENING THE CHASSIS MAY CAUSE SERIOUS...

Страница 7: ...re isolated This provides support of positive or negative power connections Power Options WARNING Note the wire colors used in making the positive negative and ground connections Use the same color as...

Страница 8: ...g at 1Hz Port linked at 100Mbps and in redundant secondary mode Amber Blinking at 1Hz Port linked at 100Mbps and receiving Far End Fault Indicator FEFI 1000 OFF No link Green ON Port linked at 1000Mbp...

Страница 9: ...Fiber Fixed ST SC LC 1000BASE X Fiber SFP 10 100 1000BASE T SGMII Copper Transceiver or 1000BASE X Fiber Transceiver Serial RJ 45 RS 232 Cable Types Copper EIA TIA 568A B Cat 5 UTP and higher Fiber M...

Страница 10: ...s product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support omnitron systems com URL www omnitro...

Отзывы: