Omnitron Systems FlexPoint 4385 Скачать руководство пользователя страница 4

Page 8

Page 7

removal and installation steps must be strictly followed in order to prevent serious 

injury or death or serious damage to your equipment.  Removal of power supplies 

or modules will result in access to hazardous electricity.

WARNING!!!

NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE

POWER SUPPLY OR FAN MODULE. OPENING THE CHASSIS

MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR SERVICEABLE

PARTS IN THIS UNIT.

Removal of DC Power Supply

Determine which power supply needs replacing by observing the LEDs in the front 

left of the chassis.  The top LED indicates the power status of the right power supply.  

The bottom LED indicates the power status of the left power supply.

14-Module Chassis Showing Power Supply Location and Power LEDs

If the LEDs are ON, it indicates that the power supply is operational.  If the LEDs 

are OFF, it may indicate that the DC power is not applied. Please verify that your 

DC power source is providing power.
Once you determine that your DC source is connected properly, and the power 

supply LED is still not ON, determine which is the faulty power supply unit and 

proceed to the next step.
Locate the DC circuit breaker, and switch the circuit breaker to the OFF position.
Remove the DC power cables from the faulty power supply unit and loosen the 2 

screws securing the power supply to the chassis.  Remove the faulty power supply.

Installation of DC Power Supply

Unpack the power supply carefully. Inspect for any damage.  If any damage is 

observed, do not use the power supply and call 949-250-6510 to report the damage.
Attach the power supply to the chassis. Insure that the power supply switch is in 

the OFF position.
Locate the DC circuit breaker and make sure that the switch is in the OFF position.
Reconnect the DC power source to the power supply.
Locate the DC circuit breaker and switch the circuit breaker to the ON position and 

turn the chassis power supply ON.
Observe the LED in the front of the chassis indicating that the power has been 

restored.

Specifications

Regulatory Compliances

UL, CE, FCC Class A

Environmental

RoHS, WEEE, REACH

Power Requirements

38 to 60VDC, 3.0A @ 48VDC

3-Pin Terminal 

Dimensions  (W x D x H)

19.0" x 9.5" x 3.5"  (482.6 mm x 241.3 mm x 88.9 mm)

Weight

6 lbs.  (2.72 kg.)

Temperature

Commercial:
Wide:
Storage:

0 to 50°C
-40 to 60° C (-25° C cold start)
-40 to 80°C

Humidity

5 to 95% (non-condensing)

Altitude

 - 100 to 4,000m

MTBF (hrs)

1 Power Supply:
2 Power Supplies:

43,000
172,000

Warranty

Lifetime warranty with 24/7/365 free Technical Support

Mechanical

Отзывы: