background image

Page 5

Installation Procedure

1) Configure DIP-switches

2) Installing the Module
3) Apply Power
4) Connect Cables
5) Verify Operation

1) Configure DIP-switches

DIP-switches are located on the side of the module.  The DIP-switches are used to 

configure modes of operation, networking features and PoE reset. 

DIP-switch Bank Locations

The table below provides a description of each DIP-switch position and function.

Switch

Position

Legend

Function

SW1

DOWN

Single Switch

Mode of Operation

UP

Dual Switch

SW2

DOWN

Switch

UP

Directed Switch

SW3

DOWN

Off

Uplink Redundancy

UP

Link Protection

SW4

DOWN

No Return

UP

F1 Return

SW5

DOWN

MAC Learning

MAC Learning Enabled (factory default)

UP

Off

MAC Learning Disabled

SW6

DOWN

Off

Pause Disabled (factory default)

UP

Pause

Pause Enabled

SW7

DOWN

L2CP Tunnel

L2CP Tunnel (factory default)

UP

Discard

L2CP Tunnel Discard

SW8

DOWN

Off

PoE Reset Disabled (factory default)

UP

PoE Reset

PoE Reset Enabled

DIP-switch Definitions

Page 6

SW1 and SW2:  Mode of Operation

The module supports Switch, Directed Switch and Dual Device mode.
The modes are described with MAC learning enabled.  When MAC learning is 

disabled, unicast packets are forwarded to all ports. 

SW1

SW2

Function

DOWN

DOWN

Switch Mode (factory default)

DOWN

UP

Directed Switch Mode

UP

DOWN

Dual Device Mode - Switch Mode

UP

UP

Dual Device Mode - Directed Switch Mode

Modes of Operation

Switch Mode

When  configured  for  Switch  Mode  (factory  default),  the  module  operates  as  a 

standard layer 2 switch.  Data flow will follow MAC address mapping.

Directed Switch Mode

When configured for Directed Switch Mode, traffic from all the RJ-45 user ports is only 

forwarded to the uplink port F1, preventing the broadcast traffic from flooding other 

network ports.  The data traffic on the additional uplink port (F2) is also forwarded 

to port F1. Incoming traffic from F1 follows MAC address mapping.  

Directed Switch Mode Dual Uplink Port

When  configured  for  Directed  Switch  Mode  and  Uplink  Redundancy  (per  DIP-

switches 3 and 4), traffic is forwarded to both the primary and secondary uplink 

ports.  The secondary port will block all traffic while the primary port is active.  When 

the primary port goes down, the secondary port will be active and all traffic will be 

forwarded out the secondary port (F2).

Содержание OmniConverter 10GPoE+/Sx

Страница 1: ...r can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option...

Страница 2: ...NING Potential damage to equipment and personal injury WARNING Risk of electrical shock OmniConverter 10GPoE Sx User Manual Product Overview The OmniConverter 10GPoE Sx are compact PoE PoE 10Gigabit E...

Страница 3: ...witch and Dual Device mode The modes are described with MAC learning enabled When MAC learning is disabled unicast packets are forwarded to all ports SW1 SW2 Function DOWN DOWN Switch Mode factory def...

Страница 4: ...F1 Uplink Redundancy When configured for Uplink Redundant Mode no return to primary the uplink ports operate as redundant links A fault on the primary Port F1 will cause a fail over to the secondary...

Страница 5: ...Rack Mount Shelf 8260 0 Refer to the Rack Mount Shelf user manual 040 08260 001x for the proper installation guidelines Follow the same guidelines above when rack mounting the module 3 Apply Power AC...

Страница 6: ...on the module and the negative lead of the power source to the terminal on the module as shown above Power Options WARNING Note the wire colors used in making the positive negative and ground connecti...

Страница 7: ...ault or FEFI Green single blink Port linked at 10M 100M or 1G Green two blinks Port linked at 2 5G Green three blinks Port linked at 5G Green four blinks Port linked at 10G SFP Uplink Ports LED Indica...

Страница 8: ...ondensing Altitude 100m to 4 000m operational MTBF hours Module Only 287 000 AC DC Adapter 100 000 Warranty 5 year product warranty with 24 7 365 free Technical Support 2 year AC power adapter warrant...

Отзывы: