TABLE 1: WIRE GAGE SPECIFICATIONS 

SPECIFICATIONS  

 

 

Electrical Characteristics:

 

Distance 

Gage 

5 Conductor 

6 Conductor 

 

 200 ft. (61m) 

22 

Alpha 1295C 

Alpha 1296C 

 

300 ft. (91m) 

20 

Alpha 58126 

Alpha 58126 

 

 500 ft. (153 m) 

18 

Alpha 58136 

Alpha 58136 

 

Note: Recommended cable is only a guideline, use any 

manufacturer that meets the gage and shield specifications. 

Power Supply Type: 

Linear type Recommended 

Operating Voltage Range: 

5.0 – 16 VDC (Operational down to 4.25 VDC) 

Maximum input current: 

OP10, OP20, OP90 

Standby: 35 mA 
Read: 50 mA 

   

OP30, OP40, OP45 

HOW TO TEST AND OPERATE THE READER 

   Standby: 

35 

mA 

The reader should be tested after wiring it to a  power supply 

and the host.  Do this by  performing  the following steps: 

   Read: 

100 

mA 

Tamper Output 

Open collector, active low, max.sink current is 16 mA  

1.

 

Power up the reader.  The LED and beeper will 

activate three times. This indicates that the 

reader is working properly. 

Maximum Cable Distance to Host: 

500 ft. (150 meters)

 

2.

 

Present the appropriate type of ID card to the 

reader. (See Table 2 for the correct card type 

based on the reader model.) The LED will 

momentarily flash green and a short beep will be 

emitted. This indicates that the card was read 

properly by OmniProx.  

Card Read Distance: 

See Table 2

 

Regulatory Approvals: 

USA:   UL 294 Listed & FCC Part 15 B 

       

(Model OP90 is not yet UL listed)

 

Europe: CE Listed 

3.

 

After the card data is processed by the host, the 

host can then turn the LED green or yellow. 

Refer to the host description of the LED 

operation if the reader LED is controlled by the 

host. 

Operating Temperature Range: 

-25° F to 145° F (-31°C to 63°C) 

Operating Humidity:

 

0 to 95% (non condensing) 
Suitable for outdoor use 

Dimensions:

 

 

OP10: 

Table 2: Model Number vs. Feature Matrix 

3.15” (80mm) L x 1.58” (40mm) W x 0.50” (12.8mm) D  

Model 

Number 

UL Listing 

Part # 

Card 

Type 

Output 

Format 

Read 

Range

(Max.) *

 

OP10-FW AY-K10  HID  Wiegand  3” 
OP20-FW AY-J10  HID  Wiegand  4” 
OP30-FW AY-L10  HID  Wiegand  5” 
OP40-FW AY-H10  HID  Wiegand  4” 
OP45-FW AY-M10  HID  Wiegand  4” 
OP90-FW AY-Q10  HID  Wiegand  1.5” 

*

Measured using HID Corp. Prox Card II (P/N 1326LSSMV) 

or equivalent and the corresponding OmniProx reader 

powered at 12 volts. Range also depends on electrical 

environment and/or proximity to metal. 

OP20: 

4.73” (120mm) L x 1.65” (42mm) W x 0.55” (14mm) D  

OP30: 

5.71” (145mm) L x 1.69” (43mm) W x 0.79” (20mm) D 

OP40: 

4.33” (110mm) L x 2.96” (75mm) W x 0.59” (15mm) D 

OP45: 

3.5” (89mm) L x 3.5” (89mm) W x 0.59” (15mm) D 

OP90: 

4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D 
 

For additional information on the Wiegand™ Protocol, see 
“Access Control Standard – Wiegand Card Reader Interface
SIA AC-01 (1996.10)” which can be purchased from SIA (see 
www.siaonline.org)

 

 

 

OmniProx models with HID
compatibility are capable of reading
genuine HID cards under the terms of
a license agreement between HID 
Corp. and the ADEMCO Group.

 