17. Specifications
54 www.sinetech.co.za
17. Specifications
MODEL
2KW
3KW
3KW Plus
RATED POWER
2000 W
3000 W
PV INPUT (DC)
Maximum DC Power
2250 W
3200 W
4500 W
Nominal DC Voltage
300 VDC
360 VDC
Maximum DC Voltage
350 VDC
500 VDC
Start-up Voltage / Initial Feeding Voltage
80 VDC / 120 VDC
116 VDC / 150 VDC
MPP Voltage Range
150 VDC to 320 VDC
250 VDC to 450 VDC
Maximum Input Current
15 A
13 A
18 A
Isc PV (absolute maximum)
15 A
13 A
18 A
Max. inverter back-feed current to the
array
0 A
0 A
GRID OUTPUT (AC)
Nominal Output Voltage
101/110/120/127 VAC 208/220/230/240 VAC
Output Voltage Range
88 - 127 VAC
184 - 265 VAC
Output Frequency Range
47.5 to 51.5 Hz or
57.5 to 61.5 Hz
47.5 to 51.5 Hz or
59.3to 60.5Hz
Nominal Output Current
18 A*
13 A*
Inrush Current
23 A
17 A
Maximum Output Fault Current
69 A
51 A
Maximum output Overcurrent Protection
69 A
51 A
Power Factor Range
0.9 lead to 0.9 lag
AC INPUT
AC Start-up Voltage
60 to 70 VAC
120 to 140 VAC
Auto Restart Voltage
85 VAC
180 VAC
Acceptable Input Voltage Range
80-130 VAC/80-150VAC
170 - 280 VAC
Nominal Frequency
50 Hz / 60 Hz
AC Input Power
2400VA/2400W
5100VA/5100W
Maximum AC Input Current
30 A
30 A
30 A
Inrush Input Current
30 A
30 A
30 A
BATTERY MODE OUTPUT (AC)