6. Electrical Connection 

6.1 

Safety 

 

 

 

 

6.2 

AC Side Connection 

 

1.

  Integrated RCD and RCM 

The  Omniksol  inverter is equipped with integrated RCD (Residual Current Protective 
Device) and RCM

 (

Residual Current Operated Monitor).  The current sensor will detect 

the volume of the leakage current and compare it with the pre-set value, if the leakage 

DANGER 

DANGER to life due to potential fire or electricity shock. 

NEVER

 connect or disconnect the connectors under load. 

NOTICE 

Electrical connections shall be carried out in accordance with 
the applicable regulations, such as conductor sections, fuses, 
PE connection. 

DANGER 

DANGER to life due to potential fire or electricity shock. 

With 

the inverter powered, comply with all prevailing national 
regulations on accidents prevention.

                  

This inverter 

will be directly connected with HIGH VOLTAGE power 
generation device, the installation must be performed by 
qualified personnel only in compliance with national and local 
standards and regulations.

 

Содержание Omniksol-1.5k-TL-M

Страница 1: ...User Manual V1 1 User Manual Installation Operation Omniksol 1k TL M Omniksol 1 5k TL M Omnik New Energy Co ltd...

Страница 2: ...2...

Страница 3: ...Packing checklist 14 4 1 Assembly parts 14 4 2 Product Appearance 15 4 3 Product Identification 16 4 4 Further Information 16 5 Installation 17 5 1 Safety 17 5 2 Mounting Instructions 18 5 3 Safety Cl...

Страница 4: ...4 7 3 Set Language 36 7 4 Instructions of Safety Standard selection when power up 37 7 5 State Information 38 8 Recycling and Disposal 39 9 Troubleshooting 40 10 Abbreviation 41 11 Contact 42...

Страница 5: ...eep this user manual all time available in case of emergency 1 2 Symbols Used CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury WARNING WARNIN...

Страница 6: ...re only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter NOTICE Hereby qualified personnel means he she has the valid license from the local authority...

Страница 7: ...ions including modification of product functionality of any form will affect the validation of warranty service Omnik may deny the obligation of warranty service accordingly DANGER DANGER due to elect...

Страница 8: ...h electricity generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating CAUTION The...

Страница 9: ...man Grid Regulations Certified Safety The inverter complies with the requirements of the Equipment and Product Safety Act in Europe Standards Association of Australian The inverter complies with the r...

Страница 10: ...10 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...

Страница 11: ...nables more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of pr...

Страница 12: ...V Nominal Grid Frequency 50Hz 60Hz 50Hz 60Hz Max AC Current 5 0A 6 25A Grid Voltage Range 185 276V 185 276V Grid Frequency Range 45 55Hz 55 65Hz 45 55Hz 55 65Hz Power Factor 0 99 0 99 Total Harmonic D...

Страница 13: ...P 65 According to IEC 60529 IP 65 According to IEC 60529 Cooling Concept Natural convection Natural convection Mounting Information Wall bracket Wall bracket General Data Operating Temperature Range 2...

Страница 14: ...mpleteness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 Omnik inverter B 1 p...

Страница 15: ...15 4 2 Product Appearance Front Object Description A LED light Green RUN B LED light Red FAULT C Function key for displays and choice of language Bottom A B C C A B...

Страница 16: ...type of the inverter as well as inverter specifications are specified on the side name plate The name plate is on the middle part of the right side of the inverter housing And the following figure is...

Страница 17: ...r Do not expose to rain and snow cover to enhance inverter life time The installation site MUST have good ventilation condition DANGER DANGER to life due to potential fire or electricity shock DO NOT...

Страница 18: ...re the wall you selected is strong enough to handle the screws and bear the weight of the inverter Ensure the device is properly fixed to the wall It is not recommended that the inverter is exposed to...

Страница 19: ...e following minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle Direction Minimum clearance Ab...

Страница 20: ...all mounting bracket in the carton box 2 First according to the marks drill 2 holes in the wall Then place two expansion tubes in the holes using a rubber hammer Next make 2 screws through the mountin...

Страница 21: ...21 3 Align both sides of the radiator on the hooks of the back panel move the inverter from left to right horizontally until the hooks completely into the slot of the radiator...

Страница 22: ...the left side of the inverter as the picture showed below Recommended padlock dimension A Shackle Diameter 3 5 mm B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger a...

Страница 23: ...ctricity shock NEVER connect or disconnect the connectors under load NOTICE Electrical connections shall be carried out in accordance with the applicable regulations such as conductor sections fuses P...

Страница 24: ...h of AC cable terminal length x about 14mm 0 55 of the inner wrapper then dress the conductor terminals with ferrules or tin soldering 2 Check that all parts of AC connector are present Then slide hex...

Страница 25: ...and PE conductor terminal to the appointed holes use a cross screwdriver to tighten it with tightening torque 1Nm 4 Insert the connector to clamp ring with two click sound and then tighten the hex nu...

Страница 26: ...the locker according to the direction instructed by the marks on the locker 6 If you need to separate the connectors please use a screwdriver to press the lock tongue rotate the locker according to t...

Страница 27: ...compliance with the technical data can be guaranteed For protection against electric shock PV connectors must be isolated from the power supply while being assembled or disassembled The end product mu...

Страница 28: ...he roof surface See the MC catalogue 2 Solar line for technical data and assembled parts PV Female cable coupler PV Male cable coupler Optional PV KBT4 PV KST4 PV SSH4 Touch protection mated unmated I...

Страница 29: ...6 Open end spanner A F 15 mm ill 7 Torque screwdriver A F 12 mm ill 8 Test plug PV PST Order No 32 6028 Cable preparation ill 9 Important Cables with class 2 5 or 6 construction can be connected It is...

Страница 30: ...ngages Pull lightly on the lead to check that the metal part has engaged Assembly control ill 13 Insert the test pin with the corresponding side into the socket or plug to the end position If the cont...

Страница 31: ...ntil they engage Check correct engagement by pulling on the coupling Unplugging ill 16 Compress the two snap in springs X by hand or with the PV MS tool and separate the coupling Plugging and unpluggi...

Страница 32: ...communications that is up to 50 Omnik inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at t...

Страница 33: ...check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Omnik inverter is not an aligned measuring instrument for current voltage or power consumpti...

Страница 34: ...Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table NOTICE Mak...

Страница 35: ...State information Pac xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set Language Pac xxxx W Frequency Pac xxx...

Страница 36: ...present grid current Frequency The grid frequency Model The type of the inverter Ver The Firmware version Set Language Several languages are provided for users reference to 7 3 for further information...

Страница 37: ...KWh 2 Operation steps are as following 2 1 Power on the inverter with only DC side connected while disconnecting cables of AC side 2 2 Press the Function button until the LCD displays inverter s model...

Страница 38: ...y Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC inje...

Страница 39: ...the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved coll...

Страница 40: ...s 1 Grid is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temperature 1 T...

Страница 41: ...aximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1...

Страница 42: ...86 512 6295 6676 Fax 86 512 6295 6682 Email info omnik solar com www omnik solar com Omnik German Service Center An der Pikardie 6 01277 Dresden Deutschland Tel 49 179 9762 654 Email service de omnik...

Отзывы: