Omnicomm LLS-AF 4 Sensor Setting
In the tab “Settings” under “Custom parameters”:
“Filtration” – set the output signal filtration parameters:
“No” – filtration is not performed. Applies for cases when filtration is carried out by
an external device
“Minimum” – filtration applies for cases when the device is installed in stationary
fuel storages and objects
“Average” – filtration applies for cases when vehicles operate under regular road
conditions
“Maximum” – filtration applies for cases when vehicles operate under severe road
conditions
“Severe operating conditions” – switch on if measurement values require additional
filtration with account for severe operating conditions.
“Type of signal” – select “Analog” or “Frequency”.
For the analog signal:
“Max. voltage value (5 … 20) V” – set the maximum voltage value. Default value – 5
V
“Min. voltage value (0 … 15) V” – set the minimum voltage value. Default value – 0
V
For the frequency signal:
“Max. frequency value (100 to 2000) Hz” - set the maximum frequency value. Default
value – 2000 Hz
“Min. frequency value (30 to 1900) Hz” - set the minimum frequency value. Default
value – 30 Hz
“Pull-up resistor”. Select “On” if, according to the manufacturer's instructions, the
voltage signal is connected to the input of an external device. Select “Off” if the
type of the connected signal is “dry contact” or “transistor NPN key”
For the Omnicomm Terminals:
Please select Frequency-based output in range 30…1053 Hz.
Setting
Omnicomm LLS-AF 4 Fuel Level Sensor
10