1. Introduction

1.1. Application

RCP002 is a universal remote control panel for various modes of RCPs. The user interface is designed 
for convenience, with a menu with accessible functions on the touch screen for a detailed view and clear 
functions and values.
RCP002 operates based on Ethernet using TCP/IP or Serial communication protocol. RCP002 can control 
8 different type of RCPs, directly from different manufacturers at the same time.

1.2. Features

 

•  Uses IP connectivity: generic IT Network infrastructure via standard Ethernet 10/100 Mb/s

 

•  Supports serial communication protocol connected to Omnicam4Sky RCP control unit.

 

•  Provides a remote diagnosis of RCP and the operation of the transmission.

 

•  Comfortable and ergonomic, with great flexibility and programmable buttons.

 

•  Touch screen LCD with backlight and adjustable tilt to facilitate to the maximum reading

 

•  Brightness control of LCD and led front panel.

 

•  Easy configuration and selection of the RCP number.

 

•  Support for multi-RCPs.

 

•  Mini Joystick that, depending on the mode of the RCP selected, controls the Pan & Tilt movements or 

OSD navigation.

1.3.  Use of this manual

The RCP002 can control multiple types of RCPs of various brands. This guide only includes general 
configuration functionalities.
Depending on the type of RCP that is connected to RCP002, not all elements and/or functionality may be 
available. The values available are also dependent on the RCP. The menu system only shows the relevant 
elements.
See the manual specific to the type of RCP that is connected with the RCP002. Are available for:

 

•  BMD Teranex

 

•  BMD RCP via ATEM

 

•  OmniCam4Sky HD20/HD25/HDX1

 

•  X5A OmniCam4Sky

 

•  Panasonic AW-HE50

 

•  Toshiba IK-HR1D

 

•  Vision Research Phantom V64x/Miro

Содержание RCP002

Страница 1: ...www omnicam4sky tv Universal Camera Operation Control Panel User Manual...

Страница 2: ...or a Class A digital device pursuant to part 15 of the FCC Rules CE Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a co...

Страница 3: ...as lens tissue or cotton tipped applicator with ethanol for CCD faceplate cleaning ONLY when necessary and AVOID contact with fingers or any hard object Do not use solvent abrasives or detergent when...

Страница 4: ...of the connectors on the back of the Panel 2 3 3 General Indications 2 3 4 Setting up the OCP Network Configuration Configuration using DHCP Manual Configuration Example Of Manual Configuration Networ...

Страница 5: ...ility and programmable buttons Touch screen LCD with backlight and adjustable tilt to facilitate to the maximum reading Brightness control of LCD and led front panel Easy configuration and selection o...

Страница 6: ...e Iris Black Master Preview Move the joystick up and towards below to change the iris opening Turn the bottom of the command to vary the level of black Up the part top of the knob Down to activate the...

Страница 7: ...the cursor through the menu options Turning the command increase or decrease the numeric value of the selected value This rotation is sensitive to speed so that the higher speed greater increment or...

Страница 8: ...4 with the lever 5 DB15 connector 1 1 9 8 15 2 3 4 TALLY IN SERIAL 3 4 RS232 POWER IN SERIAL 1 2 RS232 POWER IN 12V GPI OUT ETHERNET 10 100 Mb s 2X USB POWER IN SERIAL 1 2 RS232 1 GND 2 TX1 3 RX1 4 1...

Страница 9: ...12 VDC Connect the Ethernet cable from the network of RCP control to Ethernet connector Initial image appears in the RCP Panel 002 It appears the version number of the Operating System and the version...

Страница 10: ...is screen pops up a menu with options The first one should always set network configuration Network Network setting Before any device can start working on a network must be configured so that it can p...

Страница 11: ...f this is the case please contact your network administrator or change the network configuration type Static When it is configured for DHCP you cannot define additional network segments for that would...

Страница 12: ...g to configure any network device in the dark or even can reach disturbing the local network instead of connecting to this There are several changes to the assignment of the network you may want to tu...

Страница 13: ...The first represents a network routing in space that fixate the first three bytes and the fourth byte and is different on each node The other represented a network in which only the first two bytes a...

Страница 14: ...Internet Disconnect all RCP cables except power Press SETUP Select by turning 9 the Network Press 9 In the window that appears select DHCP Pulsar OK Connect a network cable to the RCP002 and connect t...

Страница 15: ...nections Once the network is configured let s indicate to the RCP which RCP you have connected 1 Select SETUP 2 Turning the 9 knob select RCP and accept pressing 9 3 Turning the 9 command select RCP i...

Страница 16: ...n This is the number that associates the RCP with the 1 to 4 buttons If you select a number between 5 and 8 the RCP is double clicked and you will not have Tally s physical connections or matrix 5 Onc...

Страница 17: ...P address 8 In Port you must press the Default button since the RCP itself has the correct values loaded according to the RCP model for RCP X5A the correct port is 10001 9 Touch the Lens tab and use t...

Страница 18: ...ect TCP 11 Enter RCP IP address 12 In the Port you must press the Default button since the RCP itself has loaded the correct values according to the lens model for the O5S lens of X5A the correct port...

Страница 19: ...does not respond directly and with the current firmware version the number continues to indicate that it is present black color when it is not Therefore if you are acting on the RCP and there is no r...

Страница 20: ...ibration 4 The Calibration window appears with two sections one for the iris control and one for the micro joystick 5 Select Iris lever 6 Move the iris control all the way down 7 Move the iris control...

Страница 21: ...ach of the commands 2 3 8 System Time Setting For RCP002 to function properly the internal clock must be set Many of the features of the operating system depend on the correct time Setting the time on...

Страница 22: ...ated to add new and improved features fix software errors or add support for new RCPs and systems The best thing is that you can upgrade by yourself without having to return to the factory to do it If...

Страница 23: ...Omnicam4Sky Lda Copyright 2018 all rights reserved Est dios Mediapro Portugal 2665 618 Venda do Pinheiro Portugal 351 218 310 680 info omnicam pt omnicam4sky omnicam4sky...

Отзывы: