NfRemote may also be downloaded at any time directly from Omnia.9’s built-in http server once certain
conditions are met:
•
Omnia.9 must be connected to your network and must have an IP addressed assigned to it via the
System > System Configuration > IP Configuration menu; DHCP is enabled by default.
•
A password must be entered in the System > System Configuration > Password menu. The factory
default is 1234.
•
The IP address/mask of the computer used to access the http server must be “white listed”
in the System > System Configuration > HTTP Access menu; the format is IP/mask (such as
192.168.1.1/255.255.255.0); wildcard characters are supported.
Once these conditions are met. you can access your Omnia.9 by entering “http://IP Address:7380” into the
address window of any standard web browser (for example, http://192.168.0.183:7380). You will see a
screen entitled “Welcome to Omnia.9 HTTP Server” with a current version number.
Under the “Downloadables” section, click on the “Download Remote Interface” link. This should be done
each time you update the software in your Omnia.9 to ensure full compatibility between the unit’s internal
software and the remote control applicaiton.
NfRemote will download to a “save to” destination folder depending upon your browser settings. To install,
double-click the executable (.exe) file. Enter the IP address and password of your Omnia.9 in the respective
fields and choose the appropriate connection type (such as mouse, VM, or touch) in the dropdown menu.
Click on the “Connect” button. You may also save this connection to the bottom portion of the window for
easy one-button recall by clicking on the “Add” button, especially handy if you are connecting to more than
one Omnia device utilizing NfRemote.
Physical Installation and Initial Configuration
Connect AC power to both of the internal power supplies. There is no power switch. When only one power
supply is connected, the unit sees this as a failure in one of the supplies and an audible alarm will result. You
can silence this alarm by pressing the small red button between the power supplies.
Redundant power supplies help protect you in the unlikely event that one fails. However, it is far more
likely that the unit will lose power because of an interruption in the AC mains circuit feeding the unit. Best
engineering practice recommends that each supply be fed from a different power source for maximum
redundancy.
Input Configuration
Connect the audio inputs as appropriate for your installation. Omnia.9 accepts balanced professional line-
level analog audio via its Left and Right Inputs in the Main Analog I/O section of the rear panel, AES/EBU
digital audio on standard XLR connectors via its Main and AES Reference Inputs in the Main Digital I/O
section of the rear panel, Aux Digital Input in the Aux Digital I/O section, and L AES67 inputs / Outputs
over IP. (AoIP is standard on new Omnia 9’s as of April, 2018. Network setup is required). Legacy users
seeking AoIP IO should contact their dealers or Telos Customer Support and ask for the MKII upgrade).
QUICK-START INSTALLATION GUIDE