4
DMAN-xxxx-xx
www.omnexcontrols.com
call toll free: 1-800-663-8806
Connector Pin Assignments
Connectors as seen from under the receiver
R160 / D160 Dimensions
ES
FA
L
STA
4.00”
5.13”
A
B
Use the Wiring Diagram and the Connector Diagram below to connect the receiver pins directly to the appropriate
contacts of the machine electronics. R160 Output Cables can be provided with every system to simplify the wiring proc-
ess. The Wire Color column below only applies to the OMNEX Output Cable configuration. Tips on mounting, power
connections and filtering are also provided under Installation Considerations.
Installing the Receiver
Wiring Diagram
Switches to Power with
Link
Power Input
(+9V to 30VDC)
Ground
Notes
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
________________
Functions
Factory Configurable Only
Factory Configurable Only
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output
Input / Output*
Input / Output*
Input / Output**
Input / Output**
Pin-Output
B7
B8
B12 - 19
B11 - 18
B10 - 17
A1 - 16
A2 - 15
A4 - 14
B9 - 13
B6 - 12
B5 - 11
B4 - 10
B3 - 9
B2 - 8
B1 - 7
A12 - 6
A10 - 5
A11 - 4
A9 - 3
A8 - 2
A7 - 1
A5
A6
A3
Wire Colors
Black/Red
White/Black
Blue/White
Blue/Black
Black/White
Green/Black
Red/White
Orange
White
Green/Black/White
Green
Red/Black/White
White/Red/Black
Orange/Red
Orange/Black
Blue/Red
White/Red
Red/Green
Orange/Green
Black/White/Red
Red
Black
Outputs: 19 solid state, high-side driver outputs, 5A max. per pin and 7A max per bank, total combined current 15A
Inputs: All output pins can be factory configured as inputs. Input pins should be connected to a current limiting (fused) source
Note: Enable output:
On when the T300
"Enable" switch is on.
StockCheck.com