Omker OMK-K373 Скачать руководство пользователя страница 6

6

4. If the controller is out of order, try to reset or check if the battery has been used up.

5. Remote control distance shorter :

1

Generally speaking, in the wide place( more than 50 meters), the effective distance may

fluctuate due to external influence like rain, flog, wind etc. that is normal.

2

If the battery is old, the effective distance will become shorter, just replace it with a new

one.

Safeties & Cautions:

1

All the operations must be implemented according to the instructions, this is very

important to personal safety.

2

Please read instructions carefully before installation.

3

Please keep the instructions properly for future use.

4

Our product is in strict accordance with the instructions for the design and manufacture.

Any violation of the instructions may damage the product or cause dangers.

5

Our company is out of responsibility for any operation or use violating the instructions.

6

Installation must comply with relevant safety standard.

7

All the machine fittings must comply with national standard related.

8

Our company is out of responsibility for the consequences caused by user’s ignoring the

process requirements of precision components during operation.

9

Safety devices (like photoelectric switch, sensor etc.)should be installed to avoid

damage.

10

Any attempts to change the structure of the components is forbidden.

11

The installation personnel should give detailed operation methods to the users as well

as the regulations under emergency, also the “instructions ”should offered.

12

Only the operations indicated in INSTRUCTIONS are allowed.

13

During installation, keep the children and other unrelated person away from the

installation site.

14

No unsafe factors around the installation site.

15

Power supply should in accordance with the demand.

16

Both the door opener and the door body must be well grounded.

Electric leakage as well as short protection device should be equipped.

17

Before electric control system operate, remove all the barriers within the door

covering area and any vehicles or person are forbidden to pass.

18

Both the installation position and height of main control box should be proper, do not

be exposed to sunlight and rain, forbidden to let children to operate the remote
controller as well as control panel switch.

19

If it is necessary to install a outer shield, consider that if it may shield signal of the

remote control.

20

Keep the remote control away from children in case of accident.

21

Any attempts to dismantle this machine privately is forbidden, only the professional

technician is allowed to make the maintenance.

22

Before system maintenance, cut off the power supply, and check if the grounding

system is correct.

Содержание OMK-K373

Страница 1: ...do not turn off you should cut off power for 5s and then connect power entering this function 3 Auto Close Function If you need auto close when external card reader or other auto release system is added you should turn on RED DIP switch 3 Auto close to ON star auto close function Then turn on RED DIP switch 6 set to ON each time you press F you will hear a sound How much time you want for the auto...

Страница 2: ...rebound more obviously You can also turn on RED DIP switch 5 to OFF turn off resistance function Not recommend 8 Anti clamping function During closing of the door when there are obstructions blocks the infrared rays the door will automatically stop and moves reversely in case of clamp people or objects It s strongly recommended to add infrared anti clamping function especially when performing auto...

Страница 3: ...terminal is for alarm lamp output please do not connect with 220V Technical parameters Input voltage 220V 10 Max output current 10A Remote distance 50m in open place without same frequency signal interference RED DIP switch turn on to ON function 1 Remote control single key function 2 Remote control lock key manual function 3 Auto close function 4 Soft star function 5 Resistance function during cl...

Страница 4: ...oo close to the control Board it is better to press at your back 2 Press Lock key of the remote control within 1 second after pressing study key of the control board 3 After studying do not long press function key of the control board D Delete all remote controls operation Long press white SN1 study delete key of the control board 8s later you will hear a sound delete all the remote controls V Opt...

Страница 5: ... normal close signal input ground sensor will be function When car or person leave ground sensor position or infrared position ground sensor function after ground sensor or infrared signal remove 3s motor star working performing auto close When signal terminal of the ground sensor detect signal input door will automatically stop and perform open action open to the limit Detect ground sensor signal...

Страница 6: ... be installed to avoid damage 10 Any attempts to change the structure of the components is forbidden 11 The installation personnel should give detailed operation methods to the users as well as the regulations under emergency also the instructions should offered 12 Only the operations indicated in INSTRUCTIONS are allowed 13 During installation keep the children and other unrelated person away fro...

Отзывы: